These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


284 related items for PubMed ID: 15117440

  • 1. Pneumatic tube system induced haemolysis: assessing sample type susceptibility to haemolysis.
    Sodi R, Darn SM, Stott A.
    Ann Clin Biochem; 2004 May; 41(Pt 3):237-40. PubMed ID: 15117440
    [Abstract] [Full Text] [Related]

  • 2. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.
    Böckel-Frohnhöfer N, Hübner U, Hummel B, Geisel J.
    Scand J Clin Lab Invest; 2014 Oct; 74(7):599-602. PubMed ID: 24909156
    [Abstract] [Full Text] [Related]

  • 3. An episode of increased hemolysis due to a defective pneumatic air tube delivery system.
    Ellis G.
    Clin Biochem; 2009 Aug; 42(12):1265-9. PubMed ID: 19445913
    [Abstract] [Full Text] [Related]

  • 4. Discrepancy between visual and spectrophotometric assessment of sample haemolysis.
    Hawkins R.
    Ann Clin Biochem; 2002 Sep; 39(Pt 5):521-2. PubMed ID: 12227862
    [Abstract] [Full Text] [Related]

  • 5. Haemolysis in neonatal blood samples: a survey of practice.
    Joshi S, Vaitkute R, Jeffery J, Ayling RM.
    Ann Clin Biochem; 2007 Mar; 44(Pt 2):178-81. PubMed ID: 17362584
    [Abstract] [Full Text] [Related]

  • 6. Influence of pneumatic tube delivery system on laboratory results.
    Makhlouf R, Fendri S, Jallouli D, Labiadh Z, Fritis L, Chaabouni K, Elleuch A, Ayadi FM.
    Ann Clin Biochem; 2024 May; 61(3):210-217. PubMed ID: 37921518
    [Abstract] [Full Text] [Related]

  • 7. The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples.
    Cakirca G, Erdal H.
    J Emerg Nurs; 2017 May; 43(3):255-258. PubMed ID: 28359708
    [Abstract] [Full Text] [Related]

  • 8. Pneumatic tube transport of blood-stained cerebrospinal fluid specimens has no clinically relevant effect on rates of haemolysis compared to manual transport.
    Jones L, Isbister G, Chesher D, Gillett M.
    Ann Clin Biochem; 2016 Jan; 53(Pt 1):168-73. PubMed ID: 26071489
    [Abstract] [Full Text] [Related]

  • 9. Smartphone Application Monitoring of Acceleration Forces During Pneumatic Tube System Transport of Emergency Department Patient Samples.
    Heireman L, Stroobants J, Uyttenbroeck W, Goossens Y, Dreezen C, Luyts D, Broeck LVD, Delanghe J, Heylen E, Mahieu B.
    Clin Lab; 2018 Jul 01; 64(7):1297-1304. PubMed ID: 30146841
    [Abstract] [Full Text] [Related]

  • 10. A prospective study of causes of haemolysis during venepuncture: tourniquet time should be kept to a minimum.
    Saleem S, Mani V, Chadwick MA, Creanor S, Ayling RM.
    Ann Clin Biochem; 2009 May 01; 46(Pt 3):244-6. PubMed ID: 19389888
    [Abstract] [Full Text] [Related]

  • 11. Use of clinical data and acceleration profiles to validate pneumatic transportation systems.
    Gils C, Broell F, Vinholt PJ, Nielsen C, Nybo M.
    Clin Chem Lab Med; 2020 Mar 26; 58(4):560-568. PubMed ID: 31804954
    [Abstract] [Full Text] [Related]

  • 12. Hemolysis of blood specimens transported from ED to laboratory by pneumatic tube.
    Stair TO, Howell JM, Fitzgerald DJ, Bailey SC, Bastasch MD.
    Am J Emerg Med; 1995 Jul 26; 13(4):484. PubMed ID: 7605542
    [No Abstract] [Full Text] [Related]

  • 13. [Pneumatic tube system for transport of laboratory samples: preanalytical aspects].
    Tóth J, Lenkey Á, V Oláh A, Köteles J, Kissné Sziráki V, Kerényi A, Kappelmayer J.
    Orv Hetil; 2014 Jul 13; 155(28):1113-20. PubMed ID: 25002315
    [Abstract] [Full Text] [Related]

  • 14. Collecting factors related to the haemolysis of blood specimens.
    Fang L, Fang SH, Chung YH, Chien ST.
    J Clin Nurs; 2008 Sep 13; 17(17):2343-51. PubMed ID: 18047574
    [Abstract] [Full Text] [Related]

  • 15. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
    Phelan MP, Reineks EZ, Hustey FM, Berriochoa JP, Podolsky SR, Meldon S, Schold JD, Chamberlin J, Procop GW.
    West J Emerg Med; 2016 Sep 13; 17(5):557-60. PubMed ID: 27625719
    [Abstract] [Full Text] [Related]

  • 16. Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis.
    Tiwari AK, Pandey P, Dixit S, Raina V.
    Clin Chem Lab Med; 2011 Nov 10; 50(3):471-4. PubMed ID: 22070350
    [Abstract] [Full Text] [Related]

  • 17. Interference in spectrophotometric analysis of cerebrospinal fluid by haemolysis induced by transport through a pneumatic tube system.
    Wenham PR, Hanson T, Ashby JP.
    Ann Clin Biochem; 2001 Jul 10; 38(Pt 4):371-5. PubMed ID: 11471879
    [Abstract] [Full Text] [Related]

  • 18. Detection of haemolysis and reporting of potassium results in samples from neonates.
    Jeffery J, Sharma A, Ayling RM.
    Ann Clin Biochem; 2009 May 10; 46(Pt 3):222-5. PubMed ID: 19261676
    [Abstract] [Full Text] [Related]

  • 19. Smartphone monitoring of pneumatic tube system-induced sample hemolysis.
    Mullins GR, Harrison JH, Bruns DE.
    Clin Chim Acta; 2016 Nov 01; 462():1-5. PubMed ID: 27553857
    [Abstract] [Full Text] [Related]

  • 20. Effect of pneumatic tube delivery system rate and distance on hemolysis of blood specimens.
    Evliyaoğlu O, Toprak G, Tekin A, Başarali MK, Kilinç C, Colpan L.
    J Clin Lab Anal; 2012 Feb 01; 26(2):66-9. PubMed ID: 22467320
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 15.