These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
917 related items for PubMed ID: 15203036
1. Determination of a novel substance P inhibitor in human plasma by high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometric detection using single and triple quadrupole detectors. Constanzer ML, Chavez-Eng CM, Dru J, Kline WF, Matuszewski BK. J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Aug 05; 807(2):243-50. PubMed ID: 15203036 [Abstract] [Full Text] [Related]
2. Simultaneous determination of Aprepitant and two metabolites in human plasma by high-performance liquid chromatography with tandem mass spectrometric detection. Chavez-Eng CM, Constanzer ML, Matuszewski BK. J Pharm Biomed Anal; 2004 Sep 03; 35(5):1213-29. PubMed ID: 15336366 [Abstract] [Full Text] [Related]
3. Quantitative high-throughput determination of endogenous retinoids in human plasma using triple-stage liquid chromatography/tandem mass spectrometry. Gundersen TE, Bastani NE, Blomhoff R. Rapid Commun Mass Spectrom; 2007 Sep 03; 21(7):1176-86. PubMed ID: 17330217 [Abstract] [Full Text] [Related]
4. Assessment of the in-vivo stereochemical integrity of aprepitant based on the analysis of human plasma samples via high-performance liquid chromatography with mass spectrometric detection. Kline WF, Woolf EJ, Matuszewski BK. Biomed Chromatogr; 2005 Sep 03; 19(7):513-7. PubMed ID: 15828059 [Abstract] [Full Text] [Related]
5. Validation and application of a high-performance liquid chromatography-tandem mass spectrometric method for simultaneous quantification of lopinavir and ritonavir in human plasma using semi-automated 96-well liquid-liquid extraction. Wang PG, Wei JS, Kim G, Chang M, El-Shourbagy T. J Chromatogr A; 2006 Oct 20; 1130(2):302-7. PubMed ID: 16919649 [Abstract] [Full Text] [Related]
6. Liquid chromatographic-electrospray tandem mass spectrometric determination of clarithromycin in human plasma. Li W, Rettig J, Jiang X, Francisco DT, Naidong W. Biomed Chromatogr; 2006 Nov 20; 20(11):1242-51. PubMed ID: 16838265 [Abstract] [Full Text] [Related]
7. Determination of dextromethorphan and its metabolite dextrorphan in human urine using high performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry: a study of selectivity of a tandem mass spectrometric assay. Constanzer ML, Chavez-Eng CM, Fu I, Woolf EJ, Matuszewski BK. J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Feb 25; 816(1-2):297-308. PubMed ID: 15664362 [Abstract] [Full Text] [Related]
8. Simultaneous determination of a novel KDR kinase inhibitor and its N-oxide metabolite in human plasma using 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry. Xu Y, Du L, Soli ED, Braun MP, Dean DC, Musson DG. J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Mar 25; 817(2):287-96. PubMed ID: 15686997 [Abstract] [Full Text] [Related]
9. Rapid and sensitive liquid chromatography-tandem mass spectrometric method for the quantitation of metformin in human plasma. Wang Y, Tang Y, Gu J, Fawcett JP, Bai X. J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Sep 05; 808(2):215-9. PubMed ID: 15261814 [Abstract] [Full Text] [Related]
10. Determination of a prostaglandin D2 antagonist and its acyl glucuronide metabolite in human plasma by high performance liquid chromatography with tandem mass spectrometric detection--a lack of MS/MS selectivity between a glucuronide conjugate and a phase I metabolite. Schwartz MS, Desai RB, Bi S, Miller AR, Matuszewski BK. J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Jun 06; 837(1-2):116-24. PubMed ID: 16716772 [Abstract] [Full Text] [Related]
11. [Determination of mosapride in human plasma by high performance liquid chromatography tandem mass spectrometry]. Qin F, Chen LY, Ma YY, Wang D, Liu J, Lu XM, Li FM. Yao Xue Xue Bao; 2007 Aug 06; 42(8):882-5. PubMed ID: 17944240 [Abstract] [Full Text] [Related]
12. Simultaneous determination of three bufadienolides in rat plasma after intravenous administration of bufadienolides extract by ultra performance liquid chromatography electrospray ionization tandem mass spectrometry. Zhang Y, Tang X, Liu X, Li F, Lin X. Anal Chim Acta; 2008 Mar 10; 610(2):224-31. PubMed ID: 18291133 [Abstract] [Full Text] [Related]
13. Simultaneous determination of nicotinic acid and its four metabolites in rat plasma using high performance liquid chromatography with tandem mass spectrometric detection (LC/MS/MS). Szafarz M, Lomnicka M, Sternak M, Chlopicki S, Szymura-Oleksiak J. J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Apr 01; 878(11-12):895-902. PubMed ID: 20223714 [Abstract] [Full Text] [Related]
14. Determination of a novel gamma-secretase inhibitor in human plasma and cerebrospinal fluid using automated 96 well solid phase extraction and liquid chromatography/tandem mass spectrometry. Matthews CZ, Woolf EJ. J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Feb 15; 863(1):36-45. PubMed ID: 18249589 [Abstract] [Full Text] [Related]
15. Sensitive liquid chromatographic/tandem mass spectrometric method for the determination of beclomethasone dipropionate and its metabolites in equine plasma and urine. Guan F, Uboh C, Soma L, Hess A, Luo Y, Tsang DS. J Mass Spectrom; 2003 Aug 15; 38(8):823-38. PubMed ID: 12938103 [Abstract] [Full Text] [Related]
16. High performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI) method for simultaneous determination of venlafaxine and its three metabolites in human plasma. Liu W, Cai HL, Li HD. J Chromatogr B Analyt Technol Biomed Life Sci; 2007 May 01; 850(1-2):405-11. PubMed ID: 17222591 [Abstract] [Full Text] [Related]
17. Measurement of ethyl methanesulfonate in human plasma and breast milk samples using high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry. Montesano MA, Whitehead RD, Jayatilaka NK, Kuklenyik P, Davis MD, Needham LL, Barr DB. J Pharm Biomed Anal; 2010 Jun 05; 52(2):260-4. PubMed ID: 20102787 [Abstract] [Full Text] [Related]
18. Intracellular measurements of anti-HIV drugs indinavir, amprenavir, saquinavir, ritonavir, nelfinavir, lopinavir, atazanavir, efavirenz and nevirapine in peripheral blood mononuclear cells by liquid chromatography coupled to tandem mass spectrometry. Colombo S, Beguin A, Telenti A, Biollaz J, Buclin T, Rochat B, Decosterd LA. J Chromatogr B Analyt Technol Biomed Life Sci; 2005 May 25; 819(2):259-76. PubMed ID: 15833290 [Abstract] [Full Text] [Related]
19. Determination of tamsulosin in dog plasma by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry. Qi M, Wang P, Liu L. J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Jun 05; 805(1):7-11. PubMed ID: 15113533 [Abstract] [Full Text] [Related]
20. High-throughput determination of atrasentan in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry. Wang PG, Wei J, Chang M, El-Shourbagy T. Biomed Chromatogr; 2005 Nov 05; 19(9):663-70. PubMed ID: 15803446 [Abstract] [Full Text] [Related] Page: [Next] [New Search]