These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


319 related items for PubMed ID: 15241101

  • 21.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 22. Estimation of extravascular lung water using the transpulmonary ultrasound dilution (TPUD) method: a validation study in neonatal lambs.
    Vrancken SL, Nusmeier A, Hopman JC, Liem KD, van der Hoeven JG, Lemson J, van Heijst AF, de Boode WP.
    J Clin Monit Comput; 2016 Dec; 30(6):985-994. PubMed ID: 26563187
    [Abstract] [Full Text] [Related]

  • 23. Effect of a catecholamine-induced increase in cardiac output on extravascular lung water.
    García-Delgado M, Colmenero-Ruiz M, Fernández-Sacristán MA, Rus-Mansilla C, Fernández-Mondéjar E.
    Crit Care Med; 2001 May; 29(5):931-5. PubMed ID: 11378599
    [Abstract] [Full Text] [Related]

  • 24. Simplified lung ultrasound protocol shows excellent prediction of extravascular lung water in ventilated intensive care patients.
    Enghard P, Rademacher S, Nee J, Hasper D, Engert U, Jörres A, Kruse JM.
    Crit Care; 2015 Feb 06; 19(1):36. PubMed ID: 25656060
    [Abstract] [Full Text] [Related]

  • 25. Measurement of extravascular lung water in dogs using the thermal-green dye indicator dilution method.
    Mihm FG, Feeley TW, Rosenthal MH, Lewis F.
    Anesthesiology; 1982 Aug 06; 57(2):116-22. PubMed ID: 7046519
    [Abstract] [Full Text] [Related]

  • 26. Quantification of lung water by transpulmonary thermodilution in normal and edematous lung.
    Fernández-Mondéjar E, Castaño-Pérez J, Rivera-Fernández R, Colmenero-Ruiz M, Manzano F, Pérez-Villares J, de la Chica R.
    J Crit Care; 2003 Dec 06; 18(4):253-8. PubMed ID: 14691899
    [Abstract] [Full Text] [Related]

  • 27. Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome.
    Jozwiak M, Silva S, Persichini R, Anguel N, Osman D, Richard C, Teboul JL, Monnet X.
    Crit Care Med; 2013 Feb 06; 41(2):472-80. PubMed ID: 23263578
    [Abstract] [Full Text] [Related]

  • 28. Accuracy of the double indicator method for measurement of extravascular lung water depends on the type of acute lung injury.
    Roch A, Michelet P, Lambert D, Delliaux S, Saby C, Perrin G, Ghez O, Bregeon F, Thomas P, Carpentier JP, Papazian L, Auffray JP.
    Crit Care Med; 2004 Mar 06; 32(3):811-7. PubMed ID: 15090967
    [Abstract] [Full Text] [Related]

  • 29. B-Lines Scores Derived From Lung Ultrasound Provide Accurate Prediction of Extravascular Lung Water Index: An Observational Study in Critically Ill Patients.
    Mayr U, Lukas M, Habenicht L, Wiessner J, Heilmaier M, Ulrich J, Rasch S, Schmid RM, Lahmer T, Huber W, Herner A.
    J Intensive Care Med; 2022 Jan 06; 37(1):21-31. PubMed ID: 33148110
    [Abstract] [Full Text] [Related]

  • 30. Extravascular lung water after pneumonectomy and one-lung ventilation in sheep.
    Kuzkov VV, Suborov EV, Kirov MY, Kuklin VN, Sobhkhez M, Johnsen S, Waerhaug K, Bjertnaes LJ.
    Crit Care Med; 2007 Jun 06; 35(6):1550-9. PubMed ID: 17440418
    [Abstract] [Full Text] [Related]

  • 31. The thermal-dye method of lung water measurement is reliable at a low cardiac output.
    Calcagni DE, Mihm FG, Feeley TW, Halperin BD, Rosenthal MH.
    J Surg Res; 1986 Sep 06; 41(3):286-92. PubMed ID: 3762135
    [Abstract] [Full Text] [Related]

  • 32. Serial measurement of extravascular lung water and blood volume during the course of neurogenic pulmonary edema after subarachnoid hemorrhage: initial experience with 3 cases.
    Mutoh T, Kazumata K, Kobayashi S, Terasaka S, Ishikawa T.
    J Neurosurg Anesthesiol; 2012 Jul 06; 24(3):203-8. PubMed ID: 22193041
    [Abstract] [Full Text] [Related]

  • 33. Furosemide, when used in combination with positive end-expiratory pressure, facilitates the resorption of extravascular lung water in experimental hydrostatic pulmonary oedema.
    Wickerts CJ, Blomqvist H, Berg B, Rösblad PG, Hedenstierna G.
    Acta Anaesthesiol Scand; 1991 Nov 06; 35(8):776-83. PubMed ID: 1763601
    [Abstract] [Full Text] [Related]

  • 34. Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children.
    Proulx F, Lemson J, Choker G, Tibby SM.
    Pediatr Crit Care Med; 2011 Jul 06; 12(4):459-66. PubMed ID: 21263372
    [Abstract] [Full Text] [Related]

  • 35. Sildenafil prevents the increase of extravascular lung water and pulmonary hypertension after meconium aspiration in newborn piglets.
    Silvera FE, Blasina MF, Vaamonde L, Tellechea S, Godoy C, Zabala S, Mañana G, Martell M, Olivera W.
    Braz J Med Biol Res; 2011 Aug 06; 44(8):778-85. PubMed ID: 21755265
    [Abstract] [Full Text] [Related]

  • 36. Factors influencing the estimation of extravascular lung water by transpulmonary thermodilution in critically ill patients.
    Michard F, Schachtrupp A, Toens C.
    Crit Care Med; 2005 Jun 06; 33(6):1243-7. PubMed ID: 15942338
    [Abstract] [Full Text] [Related]

  • 37. Assessment of Pulmonary Edema: Principles and Practice.
    Assaad S, Kratzert WB, Shelley B, Friedman MB, Perrino A.
    J Cardiothorac Vasc Anesth; 2018 Apr 06; 32(2):901-914. PubMed ID: 29174750
    [Abstract] [Full Text] [Related]

  • 38. Redistribution of pulmonary blood flow impacts thermodilution-based extravascular lung water measurements in a model of acute lung injury.
    Easley RB, Mulreany DG, Lancaster CT, Custer JW, Fernandez-Bustamante A, Colantuoni E, Simon BA.
    Anesthesiology; 2009 Nov 06; 111(5):1065-74. PubMed ID: 19809280
    [Abstract] [Full Text] [Related]

  • 39. In vivo validation of the thermal-green dye technique for measuring extravascular lung water.
    Slutsky RA, Higgins CB.
    Crit Care Med; 1985 May 06; 13(5):432-5. PubMed ID: 3886293
    [Abstract] [Full Text] [Related]

  • 40.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 16.