These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
513 related items for PubMed ID: 15290114
1. Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts. Hambye AS, Vervaet A, Dobbeleir A. Eur J Nucl Med Mol Imaging; 2004 Dec; 31(12):1606-13. PubMed ID: 15290114 [Abstract] [Full Text] [Related]
2. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT. Schaefer WM, Lipke CS, Standke D, Kühl HP, Nowak B, Kaiser HJ, Koch KC, Buell U. J Nucl Med; 2005 Aug; 46(8):1256-63. PubMed ID: 16085580 [Abstract] [Full Text] [Related]
3. Comparison of two software in gated myocardial perfusion single photon emission tomography, for the measurement of left ventricular volumes and ejection fraction, in patients with and without perfusion defects. Kakhki VR, Zakavi SR, Sadeghi R. Hell J Nucl Med; 2007 Aug; 10(1):19-23. PubMed ID: 17450245 [Abstract] [Full Text] [Related]
4. Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging. Lipke CS, Kühl HP, Nowak B, Kaiser HJ, Reinartz P, Koch KC, Buell U, Schaefer WM. Eur J Nucl Med Mol Imaging; 2004 Apr; 31(4):482-90. PubMed ID: 14722679 [Abstract] [Full Text] [Related]
8. Gender differences in ventricular volumes and left ventricle ejection fraction estimated by myocardial perfusion imaging: comparison of Quantitative Gated SPECT (QGS) and Segami software programs. Yamada AT, Campos Neto Gde C, Soares J, Giorgi MC, Araújo F, Meneghetti JC, Mansur AJ. Arq Bras Cardiol; 2007 Mar; 88(3):285-90. PubMed ID: 17533469 [Abstract] [Full Text] [Related]
9. Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET: comparison with cardiac MRI. Schaefer WM, Lipke CS, Nowak B, Kaiser HJ, Reinartz P, Buecker A, Krombach GA, Buell U, Kühl HP. J Nucl Med; 2004 Jan; 45(1):74-9. PubMed ID: 14734676 [Abstract] [Full Text] [Related]
13. Gated myocardial perfusion SPECT underestimates left ventricular volumes and shows high variability compared to cardiac magnetic resonance imaging -- a comparison of four different commercial automated software packages. Hedeer F, Palmer J, Arheden H, Ugander M. BMC Med Imaging; 2010 May 25; 10():10. PubMed ID: 20500866 [Abstract] [Full Text] [Related]