These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
510 related items for PubMed ID: 15353722
1. Alanine and TLD coupled detectors for fast neutron dose measurements in neutron capture therapy (NCT). Cecilia A, Baccaro S, Cemmi A, Colli V, Gambarini G, Rosi G, Scolari L. Radiat Prot Dosimetry; 2004; 110(1-4):637-40. PubMed ID: 15353722 [Abstract] [Full Text] [Related]
2. Study of a method based on TLD detectors for in-phantom dosimetry in BNCT. Gambarini G, Klamert V, Agosteo S, Birattari C, Gay S, Rosi G, Scolari L. Radiat Prot Dosimetry; 2004; 110(1-4):631-6. PubMed ID: 15353721 [Abstract] [Full Text] [Related]
10. Combined TL and 10B-alanine ESR dosimetry for BNCT. Bartolotta A, D'Oca MC, Lo Giudice B, Brai M, Borio R, Forini N, Salvadori P, Manera S. Radiat Prot Dosimetry; 2004; 110(1-4):627-30. PubMed ID: 15353720 [Abstract] [Full Text] [Related]
11. An accelerator-based epithermal neutron beam design for BNCT and dosimetric evaluation using a voxel head phantom. Lee DJ, Han CY, Park SH, Kim JK. Radiat Prot Dosimetry; 2004; 110(1-4):655-60. PubMed ID: 15353726 [Abstract] [Full Text] [Related]
12. Microdosimetry of neutron field for boron neutron capture therapy at Kyoto university reactor. Endo S, Onizuka Y, Ishikawa M, Takada M, Sakurai Y, Kobayashi T, Tanaka K, Hoshi M, Shizuma K. Radiat Prot Dosimetry; 2004; 110(1-4):641-4. PubMed ID: 15353723 [Abstract] [Full Text] [Related]
13. Development of a tiny neutron probe with an optical fibre for BNCT. Ito Y, Katano G, Harano H, Matsumoto T, Uritani A, Kudo K, Kobayashi K, Yoshimoto T, Sakurai Y, Kobayashi T, Mori C. Radiat Prot Dosimetry; 2004; 110(1-4):619-22. PubMed ID: 15353718 [Abstract] [Full Text] [Related]
14. Dosimetric measurements with a brain equivalent plastic walled ionization chamber in an epithermal neutron beam. Binns PJ, Riley KJ, Harling OK. Radiat Prot Dosimetry; 2004; 110(1-4):687-92. PubMed ID: 15353731 [Abstract] [Full Text] [Related]
15. Recombination chambers filled with different gases--studies of possible application for BNCT beam dosimetry. Tulik P, Golnik N, Zielczynski M. Radiat Prot Dosimetry; 2004; 110(1-4):669-73. PubMed ID: 15353728 [Abstract] [Full Text] [Related]
16. Self-shielding effects in neutron spectra measurements for neutron capture therapy by means of activation foils. Pytel K, Józefowicz K, Pytel B, Koziel A. Radiat Prot Dosimetry; 2004; 110(1-4):823-6. PubMed ID: 15353753 [Abstract] [Full Text] [Related]
20. Calibration and testing of a TLD dosemeter for area monitoring. Buchillier T, Aroua A, Bochud F, Schuler C, Stritt N, Valley JF, Wernli C. Radiat Prot Dosimetry; 2004; 110(1-4):705-10. PubMed ID: 15353735 [Abstract] [Full Text] [Related] Page: [Next] [New Search]