These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
351 related items for PubMed ID: 15354108
1. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves. Bottio T, Caprili L, Casarotto D, Gerosa G. J Thorac Cardiovasc Surg; 2004 Sep; 128(3):457-62. PubMed ID: 15354108 [Abstract] [Full Text] [Related]
2. Small aortic annulus: the hydrodynamic performances of 5 commercially available tissue valves. Gerosa G, Tarzia V, Rizzoli G, Bottio T. J Thorac Cardiovasc Surg; 2006 May; 131(5):1058-64. PubMed ID: 16678590 [Abstract] [Full Text] [Related]
3. In-vitro testing of three totally supra-annular bileaflet mechanical valves: hydrodynamics in the Sheffield pulse duplicator. Bottio T, Tarzia V, Rizzoli G, Gerosa G. J Heart Valve Dis; 2008 Mar; 17(2):222-6. PubMed ID: 18512495 [Abstract] [Full Text] [Related]
4. In vitro comparison of different mechanical prostheses suitable for replacement of the systemic atrioventricular valve in children. Bottio T, Dal Lin C, Lika A, Rizzoli G, Tarzia V, Buratto E, Gerosa G. J Thorac Cardiovasc Surg; 2012 Mar; 143(3):558-68. PubMed ID: 21890150 [Abstract] [Full Text] [Related]
5. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves. Reul H, van Son JA, Steinseifer U, Schmitz B, Schmidt A, Schmitz C, Rau G. J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181 [Abstract] [Full Text] [Related]
6. [Doppler echocardiographic evaluation of the new mechanical bileaflet Sorin Bicarbon valve prosthesis compared with St. Jude Medical]. Badano L, Carratino L, De Gaetano G, Piazza R, Calisi P, Passerone G, Lucatti A. G Ital Cardiol; 1994 Jun; 24(6):733-43. PubMed ID: 8088472 [Abstract] [Full Text] [Related]
7. The new St. Jude Medical regent mechanical heart valve: laboratory measurements of hydrodynamic performance. Walker DK, Brendzel AM, Scotten LN. J Heart Valve Dis; 1999 Nov; 8(6):687-96. PubMed ID: 10616249 [Abstract] [Full Text] [Related]
8. Comparative evaluation of small-size Sorin Slimline and St. Jude HP heart valve prostheses. Otero E, Pomar JL, Revuelta JM, Rufilanchas JJ. Ann Thorac Surg; 2005 Apr; 79(4):1284-90. PubMed ID: 15797063 [Abstract] [Full Text] [Related]
9. Hemodynamics of high-performance bileaflet valves: comparison to simulated clinical Doppler measurements. Dohmen G, Schmitz C, Schmitz-Rode T, Steinseifer U, Autschbach R. J Heart Valve Dis; 2006 Jul; 15(4):549-56. PubMed ID: 16901053 [Abstract] [Full Text] [Related]
10. Valve replacement with bileaflet HP-Biplus mechanical prostheses versus standard prostheses: long-term results. Cianciulli TF, Lax JA, Beck MA, Guidoin R, Saccheri MC, Cosarinsky LA, Gadea FJ, Dorelle AN, Prezioso HA, Vidal LA. J Heart Valve Dis; 2008 Mar; 17(2):206-15. PubMed ID: 18512493 [Abstract] [Full Text] [Related]
11. The changing spectrum of bioprostheses hydrodynamic performance: considerations on in-vitro tests. Bottio T, Tarzia V, Rizzoli G, Gerosa G. Interact Cardiovasc Thorac Surg; 2008 Oct; 7(5):750-4. PubMed ID: 18628343 [Abstract] [Full Text] [Related]
12. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model. Dumont K, Vierendeels J, Kaminsky R, van Nooten G, Verdonck P, Bluestein D. J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477 [Abstract] [Full Text] [Related]
13. Doppler assessment of mechanical aortic valve prostheses: effect of valve design and size of the aorta. Mascherbauer J, Schima H, Maurer G, Baumgartner H. J Heart Valve Dis; 2004 Sep; 13(5):823-30. PubMed ID: 15473486 [Abstract] [Full Text] [Related]
14. Serial Doppler echocardiographic evaluation of small-sized sorin bicarbon prostheses. De Carlo M, Milano AD, Nardi C, Mecozzi G, Bortolotti U. J Thorac Cardiovasc Surg; 2003 Aug; 126(2):337-43. PubMed ID: 12928629 [Abstract] [Full Text] [Related]
15. Hemolysis parameters of St. Jude Medical: Hemodynamic Plus and Regent valves in aortic position. Suedkamp M, Lercher AJ, Mueller-Riemenschneider F, LaRosee K, Tossios P, Mehlhorn U. Int J Cardiol; 2004 May; 95(1):89-93. PubMed ID: 15159044 [Abstract] [Full Text] [Related]
16. In vitro comparison of aortic heart valve prostheses. Part 1: Mechanical valves. Knott E, Reul H, Knoch M, Steinseifer U, Rau G. J Thorac Cardiovasc Surg; 1988 Dec; 96(6):952-61. PubMed ID: 3193804 [Abstract] [Full Text] [Related]
17. A single-center experience of the Sorin Bicarbon heart valve prosthesis: long-term clinical, hematological and hemodynamic results. Whitaker DC, James SE, Walesby RK. J Heart Valve Dis; 2004 Jan; 13(1):97-102. PubMed ID: 14765847 [Abstract] [Full Text] [Related]
18. Hemodynamic performance of the 21-mm Sorin Bicarbon mechanical aortic prostheses using dobutamine Doppler echocardiography. Kadir I, Wan IY, Walsh C, Wilde P, Bryan AJ, Angelini GD. Ann Thorac Surg; 2001 Jul; 72(1):49-53. PubMed ID: 11465229 [Abstract] [Full Text] [Related]
19. A novel pulse duplicator system: evaluation of different valve prostheses. Haaf P, Steiner M, Attmann T, Pfister G, Cremer J, Lutter G. Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990 [Abstract] [Full Text] [Related]
20. In vitro evaluation of aortic valve prosthesis in a novel valved conduit with pseudosinuses of Valsalva. De Paulis R, Schmitz C, Scaffa R, Nardi P, Chiariello L, Reul H. J Thorac Cardiovasc Surg; 2005 Oct; 130(4):1016-21. PubMed ID: 16214513 [Abstract] [Full Text] [Related] Page: [Next] [New Search]