These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
260 related items for PubMed ID: 15465238
1. The effect of partial A2 pulley excision on gliding resistance and pulley strength in vitro. Tanaka T, Amadio PC, Zhao C, Zobitz ME, An KN. J Hand Surg Am; 2004 Sep; 29(5):877-83. PubMed ID: 15465238 [Abstract] [Full Text] [Related]
2. Primary tendon sheath enlargement and reconstruction in zone 2: an in vitro biomechanical study on tendon gliding resistance. Bunata RE, Kosmopoulos V, Simmons S, Tayag TJ, Roso M, Carlson H. J Hand Surg Am; 2009 Oct; 34(8):1436-43. PubMed ID: 19695797 [Abstract] [Full Text] [Related]
3. Gliding resistance and triggering after venting or A2 pulley enlargement: a study of intact and repaired flexor tendons in a cadaveric model. Bunata RE, Simmons S, Roso M, Kosmopoulos V. J Hand Surg Am; 2011 Aug; 36(8):1316-22. PubMed ID: 21664767 [Abstract] [Full Text] [Related]
4. Effect of A2 pulley release on repaired tendon gliding resistance and rupture in a chicken model. Tang JB, Cao Y, Wu YF, Wang GH. J Hand Surg Am; 2009 Aug; 34(6):1080-7. PubMed ID: 19643293 [Abstract] [Full Text] [Related]
5. Flexor tendon pulley V-Y plasty: an alternative to pulley venting or resection. Dona E, Walsh WR. J Hand Surg Br; 2006 Apr; 31(2):133-7. PubMed ID: 16338037 [Abstract] [Full Text] [Related]
6. Effect of finger ulnar deviation on gliding resistance of the flexor digitorum profundus tendon within the A1 and A2 pulley complex. Taguchi M, Zhao C, Zobitz ME, An KN, Amadio PC. J Hand Surg Am; 2006 Jan; 31(1):113-7. PubMed ID: 16443115 [Abstract] [Full Text] [Related]
7. Feasibility of partial A2 and A4 pulley excision: residual pulley strength. Mitsionis G, Fischer KJ, Bastidas JA, Grewal R, Pfaeffle HJ, Tomaino MM. J Hand Surg Br; 2000 Feb; 25(1):90-4. PubMed ID: 10763733 [Abstract] [Full Text] [Related]
8. Strength of tendon repair decreases in the presence of an intact A2 pulley: biomechanical study in a chicken model. Cao Y, Tang JB. J Hand Surg Am; 2009 Dec; 34(10):1763-70. PubMed ID: 19969186 [Abstract] [Full Text] [Related]
9. The effects of oblique or transverse partial excision of the A2 pulley on gliding resistance during cyclic motion following zone II flexor digitorum profundus repair in a cadaveric model. Moriya T, Thoreson AR, Zhao C, An KN, Amadio PC. J Hand Surg Am; 2012 Aug; 37(8):1634-8. PubMed ID: 22763054 [Abstract] [Full Text] [Related]
10. Effect of gap size on gliding resistance after flexor tendon repair. Zhao C, Amadio PC, Tanaka T, Kutsumi K, Tsubone T, Zobitz ME, An KN. J Bone Joint Surg Am; 2004 Nov; 86(11):2482-8. PubMed ID: 15523022 [Abstract] [Full Text] [Related]
11. Effect of A3 pulley and adjacent sheath integrity on tendon excursion and bowstringing. Tang JB, Xie RG. J Hand Surg Am; 2001 Sep; 26(5):855-61. PubMed ID: 11561238 [Abstract] [Full Text] [Related]
12. Gliding resistance of the flexor pollicis longus tendon after repair: does partial excision of the oblique pulley affect gliding resistance? Kutsumi K, Amadio PC, Zhao C, Zobitz ME, An KN. Plast Reconstr Surg; 2006 Nov; 118(6):1423-1428. PubMed ID: 17051113 [Abstract] [Full Text] [Related]
13. Biomechanics and histology of intact and repaired digital nerves: an in vitro study. Goldberg SH, Jobin CM, Hayes AG, Gardner T, Rosenwasser MP, Strauch RJ. J Hand Surg Am; 2007 Apr; 32(4):474-82. PubMed ID: 17398357 [Abstract] [Full Text] [Related]
14. Restoration of function of the thumb flexor apparatus requires repair of the oblique and one adjacent flexor tendon pulley. Esplin VS, Tencer AF, Hanel DP, Cosio MQ. J Orthop Res; 1996 Jan; 14(1):152-6. PubMed ID: 8618158 [Abstract] [Full Text] [Related]
15. Effect of pulley integrity on excursions and work of flexion in healing flexor tendons. Tang JB, Wang YH, Gu YT, Chen F. J Hand Surg Am; 2001 Mar; 26(2):347-53. PubMed ID: 11279583 [Abstract] [Full Text] [Related]
16. Surface markers for locating the pulleys and flexor tendon anatomy in the palm and fingers with reference to minimally invasive incisions. Gordon JA, Stone L, Gordon L. J Hand Surg Am; 2012 May; 37(5):913-8. PubMed ID: 22365712 [Abstract] [Full Text] [Related]
17. Flexor tendon-pulley interaction after pulley reconstruction: a biomechanical study in a human model in vitro. Nishida J, Amadio PC, Bettinger PC, An KN. J Hand Surg Am; 1998 Jul; 23(4):665-72. PubMed ID: 9708381 [Abstract] [Full Text] [Related]
18. Feasibility of partial A2 and A4 pulley excision: effect on finger flexor tendon biomechanics. Mitsionis G, Bastidas JA, Grewal R, Pfaeffle HJ, Fischer KJ, Tomaino MM. J Hand Surg Am; 1999 Mar; 24(2):310-4. PubMed ID: 10194015 [Abstract] [Full Text] [Related]
20. Long head biceps tenotomy versus tenodesis: a cadaveric biomechanical analysis. Wolf RS, Zheng N, Weichel D. Arthroscopy; 2005 Feb; 21(2):182-5. PubMed ID: 15689867 [Abstract] [Full Text] [Related] Page: [Next] [New Search]