These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
599 related items for PubMed ID: 15498895
1. Malignant versus benign nodules at CT screening for lung cancer: comparison of thin-section CT findings. Li F, Sone S, Abe H, Macmahon H, Doi K. Radiology; 2004 Dec; 233(3):793-8. PubMed ID: 15498895 [Abstract] [Full Text] [Related]
2. Persistent pulmonary nodular ground-glass opacity at thin-section CT: histopathologic comparisons. Kim HY, Shim YM, Lee KS, Han J, Yi CA, Kim YK. Radiology; 2007 Oct; 245(1):267-75. PubMed ID: 17885195 [Abstract] [Full Text] [Related]
3. [A study of high-resolution computed tomography (HRCT) findings of resected small pulmonary nodules 2 cm or less in diameter with reference to the malignant nature]. Nakashima Y, Yamada T, Tanahashi M, Hikosaka Y, Yoshitomi H, Niwa H. Kyobu Geka; 2006 Sep; 59(10):917-22. PubMed ID: 16986688 [Abstract] [Full Text] [Related]
4. Volume-doubling time of pulmonary nodules with ground glass opacity at multidetector CT: Assessment with computer-aided three-dimensional volumetry. Oda S, Awai K, Murao K, Ozawa A, Utsunomiya D, Yanaga Y, Kawanaka K, Yamashita Y. Acad Radiol; 2011 Jan; 18(1):63-9. PubMed ID: 21145028 [Abstract] [Full Text] [Related]
5. Small solitary pulmonary nodules (< or =1 cm) detected at population-based CT screening for lung cancer: Reliable high-resolution CT features of benign lesions. Takashima S, Sone S, Li F, Maruyama Y, Hasegawa M, Matsushita T, Takayama F, Kadoya M. AJR Am J Roentgenol; 2003 Apr; 180(4):955-64. PubMed ID: 12646435 [Abstract] [Full Text] [Related]
6. Clinical, pathological and thin-section CT features of persistent multiple ground-glass opacity nodules: comparison with solitary ground-glass opacity nodule. Kim TJ, Goo JM, Lee KW, Park CM, Lee HJ. Lung Cancer; 2009 May; 64(2):171-8. PubMed ID: 18799230 [Abstract] [Full Text] [Related]
7. Evaluation of F-18 fluorodeoxyglucose (FDG) PET scanning for pulmonary nodules less than 3 cm in diameter, with special reference to the CT images. Nomori H, Watanabe K, Ohtsuka T, Naruke T, Suemasu K, Uno K. Lung Cancer; 2004 Jul; 45(1):19-27. PubMed ID: 15196730 [Abstract] [Full Text] [Related]
8. Thin-section computed tomography-histopathologic comparisons of pulmonary focal interstitial fibrosis, atypical adenomatous hyperplasia, adenocarcinoma in situ, and minimally invasive adenocarcinoma with pure ground-glass opacity. Si MJ, Tao XF, Du GY, Cai LL, Han HX, Liang XZ, Zhao JM. Eur J Radiol; 2016 Oct; 85(10):1708-1715. PubMed ID: 27666606 [Abstract] [Full Text] [Related]
9. Pulmonary lesions detected in population-based CT screening for lung cancer: reliable findings of benign lesions. Murakami T, Yasuhara Y, Yoshioka S, Uemura M, Mochizuki T, Ikezoe J. Radiat Med; 2004 Oct; 22(5):287-95. PubMed ID: 15553008 [Abstract] [Full Text] [Related]
10. Rapidly growing small peripheral lung cancers detected by screening CT: correlation between radiological appearance and pathological features. Wang JC, Sone S, Feng L, Yang ZG, Takashima S, Maruyama Y, Hasegawa M, Kawakami S, Honda T, Yamanda T. Br J Radiol; 2000 Sep; 73(873):930-7. PubMed ID: 11064644 [Abstract] [Full Text] [Related]
11. Five-year lung cancer screening experience: CT appearance, growth rate, location, and histologic features of 61 lung cancers. Lindell RM, Hartman TE, Swensen SJ, Jett JR, Midthun DE, Tazelaar HD, Mandrekar JN. Radiology; 2007 Feb; 242(2):555-62. PubMed ID: 17255425 [Abstract] [Full Text] [Related]
12. Predictive value of one-dimensional mean computed tomography value of ground-glass opacity on high-resolution images for the possibility of future change. Tamura M, Shimizu Y, Yamamoto T, Yoshikawa J, Hashizume Y. J Thorac Oncol; 2014 Apr; 9(4):469-72. PubMed ID: 24736068 [Abstract] [Full Text] [Related]
13. Indeterminate solitary pulmonary nodules revealed at population-based CT screening of the lung: using first follow-up diagnostic CT to differentiate benign and malignant lesions. Takashima S, Sone S, Li F, Maruyama Y, Hasegawa M, Kadoya M. AJR Am J Roentgenol; 2003 May; 180(5):1255-63. PubMed ID: 12704034 [Abstract] [Full Text] [Related]
14. Smooth or attached solid indeterminate nodules detected at baseline CT screening in the NELSON study: cancer risk during 1 year of follow-up. Xu DM, van der Zaag-Loonen HJ, Oudkerk M, Wang Y, Vliegenthart R, Scholten ET, Verschakelen J, Prokop M, de Koning HJ, van Klaveren RJ. Radiology; 2009 Jan; 250(1):264-72. PubMed ID: 18984780 [Abstract] [Full Text] [Related]
15. Thin-section CT findings in peripheral lung cancer of 3 cm or smaller: are there any characteristic features for predicting tumor histology or do they depend only on tumor size? Jiang B, Takashima S, Miyake C, Hakucho T, Takahashi Y, Morimoto D, Numasaki H, Nakanishi K, Tomita Y, Higashiyama M. Acta Radiol; 2014 Apr; 55(3):302-8. PubMed ID: 23926233 [Abstract] [Full Text] [Related]
16. Diagnostic accuracy of CT fluoroscopy-guided needle aspiration biopsy of ground-glass opacity pulmonary lesions. Hur J, Lee HJ, Nam JE, Kim YJ, Kim TH, Choe KO, Choi BW. AJR Am J Roentgenol; 2009 Mar; 192(3):629-34. PubMed ID: 19234257 [Abstract] [Full Text] [Related]
17. Pulmonary nodules 10 mm or less in diameter with ground-glass opacity component detected by high-resolution computed tomography have a high possibility of malignancy. Yoon HE, Fukuhara K, Michiura T, Takada M, Imakita M, Nonaka K, Iwase K. Jpn J Thorac Cardiovasc Surg; 2005 Jan; 53(1):22-8. PubMed ID: 15724498 [Abstract] [Full Text] [Related]
18. [Dynamic enhanced CT evaluation of solitary pulmonary nodules]. Ye XD, Yuan Z, Ye JD, Li HM, Xiao XS. Zhonghua Zhong Liu Za Zhi; 2011 Apr; 33(4):308-12. PubMed ID: 21575507 [Abstract] [Full Text] [Related]
19. Evaluation of automated lung nodule detection on low-dose computed tomography scans from a lung cancer screening program(1). Armato SG, Roy AS, Macmahon H, Li F, Doi K, Sone S, Altman MB. Acad Radiol; 2005 Mar; 12(3):337-46. PubMed ID: 15766694 [Abstract] [Full Text] [Related]
20. Percutaneous computed tomography-guided coaxial core biopsy for small pulmonary lesions with ground-glass attenuation. Lu CH, Hsiao CH, Chang YC, Lee JM, Shih JY, Wu LA, Yu CJ, Liu HM, Shih TT, Yang PC. J Thorac Oncol; 2012 Jan; 7(1):143-50. PubMed ID: 22124475 [Abstract] [Full Text] [Related] Page: [Next] [New Search]