These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
370 related items for PubMed ID: 15566583
41. A recruitment manoeuvre performed after endotracheal suction does not increase dynamic compliance in ventilated paediatric patients: a randomised controlled trial. Morrow B, Futter M, Argent A. Aust J Physiother; 2007; 53(3):163-9. PubMed ID: 17725473 [Abstract] [Full Text] [Related]
42. Effect of endotracheal suction on lung dynamics in mechanically-ventilated paediatric patients. Morrow B, Futter M, Argent A. Aust J Physiother; 2006; 52(2):121-6. PubMed ID: 16764549 [Abstract] [Full Text] [Related]
43. Evaluation of a portable infrared end-tidal carbon dioxide monitor during pediatric interhospital transport. Bhende MS, Karr VA, Wiltsie DC, Orr RA. Pediatrics; 1995 Jun; 95(6):875-8. PubMed ID: 7761213 [Abstract] [Full Text] [Related]
44. In vitro performance characteristics of high-frequency oscillatory ventilators. Pillow JJ, Wilkinson MH, Neil HL, Ramsden CA. Am J Respir Crit Care Med; 2001 Sep 15; 164(6):1019-24. PubMed ID: 11587990 [Abstract] [Full Text] [Related]
47. Assessment of volume and leak measurements during CPAP using a neonatal lung model. Fischer HS, Roehr CC, Proquitté H, Wauer RR, Schmalisch G. Physiol Meas; 2008 Jan 15; 29(1):95-107. PubMed ID: 18175862 [Abstract] [Full Text] [Related]
48. Supplemental inhaled gases alter tidal volume delivery and measurement. Cooper DS, Schwartz SM, Raake JL, Beam AR, Nelson DP. Pediatr Crit Care Med; 2005 Mar 15; 6(2):150-3. PubMed ID: 15730600 [Abstract] [Full Text] [Related]
49. Does endo-tracheal tube clamping prevent air leaks and maintain positive end-expiratory pressure during the switching of a ventilator in a patient in an intensive care unit? A bench study. Turbil E, Terzi N, Schwebel C, Cour M, Argaud L, Guérin C. PLoS One; 2020 Mar 15; 15(3):e0230147. PubMed ID: 32160252 [Abstract] [Full Text] [Related]
50. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator]. Schirmer U, Villwock J, Fösel T, Schreiber M, Goertz A, Georgieff M. Anaesthesist; 1992 Dec 15; 41(12):785-9. PubMed ID: 1489078 [Abstract] [Full Text] [Related]
51. Critical evaluation of emergency stockpile ventilators in an in vitro model of pediatric lung injury. Custer JW, Watson CM, Dwyer J, Kaczka DW, Simon BA, Easley RB. Pediatr Crit Care Med; 2011 Nov 15; 12(6):e357-61. PubMed ID: 21317679 [Abstract] [Full Text] [Related]
53. [The effects of endotracheal suction on gas exchange and respiratory mechanics in mechanically ventilated patients under pressure-controlled or volume-controlled ventilation]. Liu XW, Liu Z. Zhonghua Jie He He Hu Xi Za Zhi; 2007 Oct 15; 30(10):751-5. PubMed ID: 18218205 [Abstract] [Full Text] [Related]
59. Influence of compliance and resistance of the test lung on the accuracy of the tidal volume delivered by the ventilator. Chen ZL, Yan YZ, Yu HY, Wang QB, Wang W, Zhong M. BMC Pulm Med; 2024 Oct 09; 24(1):498. PubMed ID: 39385191 [Abstract] [Full Text] [Related]