These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
125 related items for PubMed ID: 15636057
1. Physical and computer modelling of blood flow in a systemic-to-pulmonary shunt. Malota Z, Nawrat Z, Kostka P, Mizerski J, Nowinski K, Waniewski J. Int J Artif Organs; 2004 Nov; 27(11):990-9. PubMed ID: 15636057 [Abstract] [Full Text] [Related]
2. The effects of graft geometry on the patency of a systemic-to-pulmonary shunt: a computational fluid dynamics study. Waniewski J, Kurowska W, Mizerski JK, Trykozko A, Nowiński K, Brzezińska-Rajszys G, Kościesza A. Artif Organs; 2005 Aug; 29(8):642-50. PubMed ID: 16048481 [Abstract] [Full Text] [Related]
3. Computer and physical modeling of blood circulation pump support for a new field of application in palliative surgery. Małota Z, Nawrat Z, Kostka P. Int J Artif Organs; 2007 Dec; 30(12):1068-74. PubMed ID: 18203068 [Abstract] [Full Text] [Related]
4. Use of mathematic modeling to compare and predict hemodynamic effects of the modified Blalock-Taussig and right ventricle-pulmonary artery shunts for hypoplastic left heart syndrome. Bove EL, Migliavacca F, de Leval MR, Balossino R, Pennati G, Lloyd TR, Khambadkone S, Hsia TY, Dubini G. J Thorac Cardiovasc Surg; 2008 Aug; 136(2):312-320.e2. PubMed ID: 18692636 [Abstract] [Full Text] [Related]
5. Numerical simulation and hemodynamic analysis of the modified Blalock-Taussig shunt. Liu J, Sun Q, Qian Y, Hong H, Liu J. Annu Int Conf IEEE Eng Med Biol Soc; 2013 Aug; 2013():707-10. PubMed ID: 24109785 [Abstract] [Full Text] [Related]
6. Development of a simple device enabling percutaneous flow regulation for a small vascular graft for a Blalock–Taussig shunt capable of flow regulation: complete translation of an original article originally published in Pediatric Cardiology and Cardiac Surgery (154–159, 2016: vol. 32). Motohashi Y, Shimada R, Sasaki T, Katsumata T, Dan K, Tsutsui Y, Nemoto S. Gen Thorac Cardiovasc Surg; 2018 Mar; 66(3):145-149. PubMed ID: 29124558 [Abstract] [Full Text] [Related]
7. In vitro hemodynamic model of the arm arteriovenous circulation to study hemodynamics of native arteriovenous fistula and the distal revascularization and interval ligation procedure. Varble N, Day S, Phillips D, Mix D, Schwarz K, Illig KA, Chandra A. J Vasc Surg; 2014 May; 59(5):1410-7. PubMed ID: 23845661 [Abstract] [Full Text] [Related]
8. Effect of arteriovenous graft flow rate on vascular access hemodynamics in a novel modular anastomotic valve device. McNally A, Akingba AG, Sucosky P. J Vasc Access; 2018 Sep; 19(5):446-454. PubMed ID: 30192183 [Abstract] [Full Text] [Related]
9. Computational fluid dynamics characterization of pulsatile flow in central and Sano shunts connected to the pulmonary arteries: importance of graft angulation on shear stress-induced, platelet-mediated thrombosis. Ascuitto R, Ross-Ascuitto N, Guillot M, Celestin C. Interact Cardiovasc Thorac Surg; 2017 Sep 01; 25(3):414-421. PubMed ID: 28525548 [Abstract] [Full Text] [Related]
10. Computational fluid dynamics of the right ventricular outflow tract and of the pulmonary artery: a bench model of flow dynamics. Mosbahi S, Mickaily-Huber E, Charbonnier D, Hullin R, Burki M, Ferrari E, von Segesser LK, Berdajs DA. Interact Cardiovasc Thorac Surg; 2014 Oct 01; 19(4):611-6. PubMed ID: 24948576 [Abstract] [Full Text] [Related]
11. Norwood with right ventricle-to-pulmonary artery conduit is more effective than Norwood with Blalock-Taussig shunt for hypoplastic left heart syndrome: mathematic modeling of hemodynamics. Mroczek T, Małota Z, Wójcik E, Nawrat Z, Skalski J. Eur J Cardiothorac Surg; 2011 Dec 01; 40(6):1412-7; discussion 1417-8. PubMed ID: 21546259 [Abstract] [Full Text] [Related]
12. Multiscale modeling of the cardiovascular system: application to the study of pulmonary and coronary perfusions in the univentricular circulation. Laganà K, Balossino R, Migliavacca F, Pennati G, Bove EL, de Leval MR, Dubini G. J Biomech; 2005 May 01; 38(5):1129-41. PubMed ID: 15797594 [Abstract] [Full Text] [Related]
13. Management of a stenotic right ventricle-pulmonary artery shunt early after the Norwood procedure. Hsia TY, Migliavacca F, Pennati G, Balossino R, Dubini G, de Leval MR, Bradley SM, Bove EL. Ann Thorac Surg; 2009 Sep 01; 88(3):830-7; discussion 837-8. PubMed ID: 19699907 [Abstract] [Full Text] [Related]
14. Computational fluid dynamics characterization of blood flow in central aorta to pulmonary artery connections: importance of shunt angulation as a determinant of shear stress-induced thrombosis. Celestin C, Guillot M, Ross-Ascuitto N, Ascuitto R. Pediatr Cardiol; 2015 Mar 01; 36(3):600-15. PubMed ID: 25404555 [Abstract] [Full Text] [Related]
15. Hemodynamics of patient-specific aorta-pulmonary shunt configurations. Piskin S, Altin HF, Yildiz O, Bakir I, Pekkan K. J Biomech; 2017 Jan 04; 50():166-171. PubMed ID: 27866675 [Abstract] [Full Text] [Related]
16. Development of the pulmonary arteries after the Norwood procedure: comparison between Blalock-Taussig shunt and right ventricular-pulmonary artery conduit. Caspi J, Pettitt TW, Mulder T, Stopa A. Ann Thorac Surg; 2008 Oct 04; 86(4):1299-304. PubMed ID: 18805181 [Abstract] [Full Text] [Related]
17. Development of an Experimental and Digital Cardiovascular Arterial Model for Transient Hemodynamic and Postural Change Studies: "A Preliminary Framework Analysis". Hewlin RL, Kizito JP. Cardiovasc Eng Technol; 2018 Mar 04; 9(1):1-31. PubMed ID: 29124548 [Abstract] [Full Text] [Related]
18. Computational model of blood flow in the aorto-coronary bypass graft. Sankaranarayanan M, Chua LP, Ghista DN, Tan YS. Biomed Eng Online; 2005 Mar 04; 4():14. PubMed ID: 15745458 [Abstract] [Full Text] [Related]
19. The effect of pulmonary circulation hemodynamics on right ventricular unloading via the bidirectional Glenn shunt: implications for congenitally corrected transposition repair. Zias EA, Mavroudis C, Cook KE, Makarewicz AJ, Backer CL, Hernandez JM. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu; 2003 Mar 04; 6():27-32. PubMed ID: 12740769 [Abstract] [Full Text] [Related]
20. Unsteady and three-dimensional simulation of blood flow in the human aortic arch. Shahcheraghi N, Dwyer HA, Cheer AY, Barakat AI, Rutaganira T. J Biomech Eng; 2002 Aug 04; 124(4):378-87. PubMed ID: 12188204 [Abstract] [Full Text] [Related] Page: [Next] [New Search]