These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Measurement of renal function by calculation of fractional uptake of technetium-99m dimercaptosuccinic acid. Beatović SLj, Jaksić ED, Han RS. Nucl Med Rev Cent East Eur; 2004; 7(1):49-52. PubMed ID: 15318311 [Abstract] [Full Text] [Related]
5. [Calculation of the partial function of the kidney with DMSA in pediatrics: is the evaluation of the geometric mean necessary?]. Porn U, Rossmüller B, Alalp S, Fischer S, Dresel S, Hahn K. Nuklearmedizin; 2001 Aug; 40(4):107-10. PubMed ID: 11556199 [Abstract] [Full Text] [Related]
6. Comparison of relative renal functions calculated with 99mTc-DTPA and 99mTc-DMSA for kidney patients of wide age ranges. Momin MA, Abdullah MNA, Reza MS. Phys Med; 2018 Jan; 45():99-105. PubMed ID: 29472098 [Abstract] [Full Text] [Related]
7. Individual renal function based on 99mTc dimercaptosuccinic acid uptake corrected for renal size. Estorch M, Torres G, Camacho V, Tembl A, Prat L, Mena E, Flotats A, Carrió I. Nucl Med Commun; 2004 Feb; 25(2):167-70. PubMed ID: 15154707 [Abstract] [Full Text] [Related]
9. Technetium-99m-dimercaptosuccinic acid renal scintigraphy can guide clinical management in congenital hydronephrosis. Bazić-Đorović B, Radulović M, Šišić M, Jauković L, Dugonjić S, Pucar D, Janković Z, Beatović S, Janković M, Krstić Z, Ajdinović B. Hell J Nucl Med; 2017 Feb; 20 Suppl():114-122. PubMed ID: 29324920 [Abstract] [Full Text] [Related]
10. [Value of the use of the geometric mean to calculate the relative renal function in 99mTc-DMSA renal scintigraphy]. Hervás Benito I, Martí Vidal FJ, Alonso Monfort J, Ruiz Rodríguez JC, González López A, Saura Quiles A, González Cabezas P, Bello Arques P, Portero Ballesteros A, Mancebo Del Rey R, Mateo Navarro A. Rev Esp Med Nucl; 2001 Dec; 20(7):517-24. PubMed ID: 11709136 [Abstract] [Full Text] [Related]
11. Estimation of Split Renal Function With 99mTc-DMSA SPECT: Comparison Between 3D Volumetric Assessment and 2D Coronal Projection Imaging. Cao X, Xu X, Grant FD, Treves ST. AJR Am J Roentgenol; 2016 Dec; 207(6):1324-1328. PubMed ID: 27623376 [Abstract] [Full Text] [Related]
12. Technetium-99m-L,L-ethylenedicysteine renal scan as a single-modality investigation for the evaluation of renal morphology and function: a comparative study with technetium-99m-dimercaptosuccinic acid. Narayana C, Tripathi M, Kumar A, Gowda NK, Phom H, Chandra P, Bandopadhyaya G, Bal C. Nucl Med Commun; 2004 Jul; 25(7):743-7. PubMed ID: 15208504 [Abstract] [Full Text] [Related]