These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


531 related items for PubMed ID: 15774850

  • 1. Aerosol deposition in neonatal ventilation.
    Dubus JC, Vecellio L, De Monte M, Fink JB, Grimbert D, Montharu J, Valat C, Behan N, Diot P.
    Pediatr Res; 2005 Jul; 58(1):10-4. PubMed ID: 15774850
    [Abstract] [Full Text] [Related]

  • 2. Comparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation.
    Harvey CJ, O'Doherty MJ, Page CJ, Thomas SH, Nunan TO, Treacher DF.
    Eur Respir J; 1997 Apr; 10(4):905-9. PubMed ID: 9150333
    [Abstract] [Full Text] [Related]

  • 3. Delivery of a nebulized aerosol to a lung model during mechanical ventilation. Effect of ventilator settings and nebulizer type, position, and volume of fill.
    O'Doherty MJ, Thomas SH, Page CJ, Treacher DF, Nunan TO.
    Am Rev Respir Dis; 1992 Aug; 146(2):383-8. PubMed ID: 1489128
    [Abstract] [Full Text] [Related]

  • 4. Aerosol deposition in mechanically ventilated patients. Optimizing nebulizer delivery.
    O'Riordan TG, Palmer LB, Smaldone GC.
    Am J Respir Crit Care Med; 1994 Jan; 149(1):214-9. PubMed ID: 8111585
    [Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6. Albuterol delivery in an in vitro pediatric ventilator lung model: comparison of jet, ultrasonic, and mesh nebulizers.
    Sidler-Moix AL, Dolci U, Berger-Gryllaki M, Pannatier A, Cotting J, Di Paolo ER.
    Pediatr Crit Care Med; 2013 Feb; 14(2):e98-102. PubMed ID: 23287904
    [Abstract] [Full Text] [Related]

  • 7. Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.
    Ari A, Atalay OT, Harwood R, Sheard MM, Aljamhan EA, Fink JB.
    Respir Care; 2010 Jul; 55(7):845-51. PubMed ID: 20587095
    [Abstract] [Full Text] [Related]

  • 8. SPECT-CT Comparison of Lung Deposition using a System combining a Vibrating-mesh Nebulizer with a Valved Holding Chamber and a Conventional Jet Nebulizer: a Randomized Cross-over Study.
    Dugernier J, Hesse M, Vanbever R, Depoortere V, Roeseler J, Michotte JB, Laterre PF, Jamar F, Reychler G.
    Pharm Res; 2017 Feb; 34(2):290-300. PubMed ID: 27822851
    [Abstract] [Full Text] [Related]

  • 9. A survey of albuterol administration practices in intubated patients in the neonatal intensive care unit.
    Ballard J, Lugo RA, Salyer JW.
    Respir Care; 2002 Jan; 47(1):31-8. PubMed ID: 11749685
    [Abstract] [Full Text] [Related]

  • 10. Radioaerosol Pulmonary Deposition Using Mesh and Jet Nebulizers During Noninvasive Ventilation in Healthy Subjects.
    Galindo-Filho VC, Ramos ME, Rattes CS, Barbosa AK, Brandão DC, Brandão SC, Fink JB, de Andrade AD.
    Respir Care; 2015 Sep; 60(9):1238-46. PubMed ID: 26106207
    [Abstract] [Full Text] [Related]

  • 11. Utility of technetium-99m-DTPA in determining regional ventilation.
    Cabahug CJ, McPeck M, Palmer LB, Cuccia A, Atkins HL, Smaldone GC.
    J Nucl Med; 1996 Feb; 37(2):239-44. PubMed ID: 8667052
    [Abstract] [Full Text] [Related]

  • 12. Albuterol delivery by 4 different nebulizers placed in 4 different positions in a pediatric ventilator in vitro model.
    Berlinski A, Willis JR.
    Respir Care; 2013 Jul; 58(7):1124-33. PubMed ID: 23107173
    [Abstract] [Full Text] [Related]

  • 13. Influence of inspiratory flow pattern and nebulizer position on aerosol delivery with a vibrating-mesh nebulizer during invasive mechanical ventilation: an in vitro analysis.
    Dugernier J, Wittebole X, Roeseler J, Michotte JB, Sottiaux T, Dugernier T, Laterre PF, Reychler G.
    J Aerosol Med Pulm Drug Deliv; 2015 Jun; 28(3):229-36. PubMed ID: 25393556
    [Abstract] [Full Text] [Related]

  • 14. In vitro comparison of five nebulizers during noninvasive ventilation: analysis of inhaled and lost doses.
    Michotte JB, Jossen E, Roeseler J, Liistro G, Reychler G.
    J Aerosol Med Pulm Drug Deliv; 2014 Dec; 27(6):430-40. PubMed ID: 24517084
    [Abstract] [Full Text] [Related]

  • 15. Pressurized Metered-Dose Inhalers Versus Nebulizers in the Treatment of Mechanically Ventilated Subjects With Artificial Airways: An In Vitro Study.
    Ari A, Harwood RJ, Sheard MM, Fink JB.
    Respir Care; 2015 Nov; 60(11):1570-4. PubMed ID: 26152470
    [Abstract] [Full Text] [Related]

  • 16. Deposition of aerosols delivered by nasal route with jet and mesh nebulizers.
    Vecellio L, De Gersem R, Le Guellec S, Reychler G, Pitance L, Le Pennec D, Diot P, Chantrel G, Bonfils P, Jamar F.
    Int J Pharm; 2011 Apr 04; 407(1-2):87-94. PubMed ID: 21256943
    [Abstract] [Full Text] [Related]

  • 17. Effect of Aerosol Devices and Administration Techniques on Drug Delivery in a Simulated Spontaneously Breathing Pediatric Tracheostomy Model.
    Alhamad BR, Fink JB, Harwood RJ, Sheard MM, Ari A.
    Respir Care; 2015 Jul 04; 60(7):1026-32. PubMed ID: 25737572
    [Abstract] [Full Text] [Related]

  • 18. Efficient drug delivery to the lungs from a continuously operated open-vent nebulizer and low pressure compressor system.
    Newman SP, Pitcairn GR, Hooper G, Knoch M.
    Eur Respir J; 1994 Jun 04; 7(6):1177-81. PubMed ID: 7925889
    [Abstract] [Full Text] [Related]

  • 19. Influence of nebulizer type with different pediatric aerosol masks on drug deposition in a model of a spontaneously breathing small child.
    Lin HL, Wan GH, Chen YH, Fink JB, Liu WQ, Liu KY.
    Respir Care; 2012 Nov 04; 57(11):1894-900. PubMed ID: 22418694
    [Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 27.