These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
724 related items for PubMed ID: 15834908
21. Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver: Comparison to Conventional Free-Breathing Turbo Spin Echo. Ichinohe F, Oyama K, Yamada A, Hayashihara H, Adachi Y, Kitoh Y, Kanki Y, Maruyama K, Nickel MD, Fujinaga Y. Invest Radiol; 2023 Jun 01; 58(6):373-379. PubMed ID: 36728880 [Abstract] [Full Text] [Related]
22. Usefulness of the application of the BLADE technique to reduce motion artifacts on navigation-triggered prospective acquisition correction (PACE) T2-weighted MRI (T2WI) of the liver. Nanko S, Oshima H, Watanabe T, Sasaki S, Hara M, Shibamoto Y. J Magn Reson Imaging; 2009 Aug 01; 30(2):321-6. PubMed ID: 19629991 [Abstract] [Full Text] [Related]
23. Detection and characterization of focal hepatic lesions by T2-weighted imaging: comparison of navigator-triggered turbo spin-echo, breath-hold turbo spin-echo, and HASTE sequences. Lee HY, Lee JM, Kim SH, Shin KS, Lee JY, Han JK, Choi BI. Clin Imaging; 2009 Aug 01; 33(4):281-8. PubMed ID: 19559350 [Abstract] [Full Text] [Related]
24. Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration. Chandarana H, Block TK, Rosenkrantz AB, Lim RP, Kim D, Mossa DJ, Babb JS, Kiefer B, Lee VS. Invest Radiol; 2011 Oct 01; 46(10):648-53. PubMed ID: 21577119 [Abstract] [Full Text] [Related]
25. In vitro comparison of water displacement method and 3 Tesla MRI for MR-volumetry of the olfactory bulb: which sequence is appropriate? Burmeister HP, Möslein C, Bitter T, Fröber R, Herrmann KH, Baltzer PA, Gudziol H, Dietzel M, Guntinas-Lichius O, Kaiser WA. Acad Radiol; 2011 Oct 01; 18(10):1233-40. PubMed ID: 21782479 [Abstract] [Full Text] [Related]
26. [Comparison of three-dimensional gradient echo, turbo spin echo and steady-state gradient echo sequences in axial MRI examination of the cervical spine]. Mahmutyazicioğlu K, Ozdemir H, Savranlar A, Ozer T, Erdem O, Erdem Z, Gündoğdu S. Tani Girisim Radyol; 2003 Dec 01; 9(4):432-8. PubMed ID: 14730951 [Abstract] [Full Text] [Related]
27. High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering. Zech CJ, Herrmann KA, Huber A, Dietrich O, Stemmer A, Herzog P, Reiser MF, Schoenberg SO. J Magn Reson Imaging; 2004 Sep 01; 20(3):443-50. PubMed ID: 15332252 [Abstract] [Full Text] [Related]
28. Lung MRI at 1.5 and 3 Tesla: observer preference study and lesion contrast using five different pulse sequences. Fink C, Puderbach M, Biederer J, Fabel M, Dietrich O, Kauczor HU, Reiser MF, Schönberg SO. Invest Radiol; 2007 Jun 01; 42(6):377-83. PubMed ID: 17507808 [Abstract] [Full Text] [Related]
29. Respiratory-triggered MRCP applying parallel acquisition techniques. Asbach P, Dewey M, Klessen C, Stemmer A, Ockenga J, Huppertz A, Sander B, Hamm B, Taupitz M. J Magn Reson Imaging; 2006 Nov 01; 24(5):1095-100. PubMed ID: 17024665 [Abstract] [Full Text] [Related]
30. [The T2-weighted half-Fourier acquired single-shot turbo-spin-echo technic compared to the conventional T2-weighted turbo-spin-echo technic for cerebral magnetic resonance tomography. A sequence comparison]. Hoffmann KT, Hosten N, Ehrenstein T, Gutberlet M, Röricht S, Felix R. Rofo; 2000 Jun 01; 172(6):521-6. PubMed ID: 10916548 [Abstract] [Full Text] [Related]
31. Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver. Altbach MI, Outwater EK, Trouard TP, Krupinski EA, Theilmann RJ, Stopeck AT, Kono M, Gmitro AF. J Magn Reson Imaging; 2002 Aug 01; 16(2):179-89. PubMed ID: 12203766 [Abstract] [Full Text] [Related]
32. T2-weighted MRI of rectosigmoid carcinoma: comparison of respiratory-triggered fast spin-echo, breathhold fast-recovery fast spin-echo, and breathhold single-shot fast spin-echo sequences. Yamashita S, Masui T, Katayama M, Sato K, Yoshizawa N, Seo H, Sakahara H. J Magn Reson Imaging; 2007 Mar 01; 25(3):511-6. PubMed ID: 17326094 [Abstract] [Full Text] [Related]
33. Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence. Ciftci E, Anik Y, Arslan A, Akansel G, Sarisoy T, Demirci A. Eur J Radiol; 2004 Sep 01; 51(3):234-40. PubMed ID: 15294330 [Abstract] [Full Text] [Related]
34. MRI of the female pelvis at 3T compared to 1.5T: evaluation on high-resolution T2-weighted and HASTE images. Kataoka M, Kido A, Koyama T, Isoda H, Umeoka S, Tamai K, Nakamoto Y, Maetani Y, Morisawa N, Saga T, Togashi K. J Magn Reson Imaging; 2007 Mar 01; 25(3):527-34. PubMed ID: 17326081 [Abstract] [Full Text] [Related]
35. [Turbo-spin-echo sequences with selective fat suppression (SPIR) in the MRI of focal liver lesions at 0.5 tesla]. Kreft B, Layer G, Kuhl C, Sommer T, Gieseke J, Schild H. Rofo; 1995 Nov 01; 163(5):411-6. PubMed ID: 8527755 [Abstract] [Full Text] [Related]
36. [Magnetic resonance with fat-saturation sequences in studying the upper abdomen: the normal semeiological aspects]. Zuiani C, Bendini M, Meduri S, Bazzocchi M, Santino P. Radiol Med; 1996 Apr 01; 91(4):405-12. PubMed ID: 8643850 [Abstract] [Full Text] [Related]
37. Fast spin-echo triple-echo Dixon: initial clinical experience with a novel pulse sequence for fat-suppressed T2-weighted abdominal MR imaging. Low RN, Ma J, Panchal N. J Magn Reson Imaging; 2009 Sep 01; 30(3):569-77. PubMed ID: 19711403 [Abstract] [Full Text] [Related]
38. [MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences]. Czerny C, Trattnig S, Baumgartner WD, Gstöttner W, Imhof H. Rofo; 1997 Oct 01; 167(4):377-83. PubMed ID: 9417266 [Abstract] [Full Text] [Related]
39. Comparison of HASTE and segmented-HASTE sequences with a T2-weighted fast spin-echo sequence in the screening evaluation of the brain. Sugahara T, Korogi Y, Hirai T, Hamatake S, Ikushima I, Shigematu Y, Takahashi M. AJR Am J Roentgenol; 1997 Nov 01; 169(5):1401-10. PubMed ID: 9353469 [Abstract] [Full Text] [Related]
40. Diffusion-weighted imaging of the liver: comparison of navigator triggered and breathhold acquisitions. Taouli B, Sandberg A, Stemmer A, Parikh T, Wong S, Xu J, Lee VS. J Magn Reson Imaging; 2009 Sep 01; 30(3):561-8. PubMed ID: 19711402 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]