These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
397 related items for PubMed ID: 15900246
1. Re-do mitral valve replacement using the valve-on-valve technique: a case report. Tamura Y, Kawata T, Kameda Y, Taniguchi S. Ann Thorac Cardiovasc Surg; 2005 Apr; 11(2):125-7. PubMed ID: 15900246 [Abstract] [Full Text] [Related]
2. [Valve-in-valve replacement of primary tissue valve failure of bovine pericardial valve minor]. Tateishi M, Koide M, Kunii Y, Watanabe K, Ohsawa M. Kyobu Geka; 2006 Jan; 59(1):61-4. PubMed ID: 16440687 [Abstract] [Full Text] [Related]
3. [Reoperation due to failure of a Freestyle bioprosthesis]. Abe T, Kawahito K, Naganuma H, Hanai M, Mashiko K, Hashimoto K. Kyobu Geka; 2008 Jul; 61(7):545-8. PubMed ID: 18616098 [Abstract] [Full Text] [Related]
4. [Re-operation of a mitral porcine bioprosthesis 22-years after implantation]. Soeda M, Hata H, Iida M, Kimura H. Kyobu Geka; 2009 Feb; 62(2):149-51. PubMed ID: 19202937 [Abstract] [Full Text] [Related]
5. [A case report: Carpentier-Edwards porcine bioprosthesis malfunction due to the stent dehiscence at 17 years after the implantation in the mitral position]. Hayashi K, Nakano H, Sakamoto T, Okamura H. Kyobu Geka; 2000 Jan; 53(1):79-82. PubMed ID: 10639799 [Abstract] [Full Text] [Related]
6. [Findings of the Carpentier-Edwards porcine bioprosthesis in the mitral position with PTF in the 16th post-operative year]. Matsuzaki K, Koishizawa T, Hiramatsu Y. Kyobu Geka; 1997 Oct; 50(11):950-3. PubMed ID: 9330518 [Abstract] [Full Text] [Related]
7. Unexpected long durability of a low-profile porcine Liotta bioprosthesis in mitral position. Campanella A, Comoglio C, Sansone F, Rinaldi M. J Cardiovasc Med (Hagerstown); 2009 Jun; 10(6):492-3. PubMed ID: 19346969 [Abstract] [Full Text] [Related]
8. Acute bioprosthetic thrombosis immediately after aortic valve replacement. Patanè F, Sansone F, Campanella A, Asteggiano F, Rinaldi M. J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):167-9. PubMed ID: 19194176 [Abstract] [Full Text] [Related]
9. Transjugular and transseptal treatment of a degenerated mitral valve prosthesis with a balloon-expandable biological valve. Schaefer U, Frerker C, Busse C, Kuck KH. Heart Lung Circ; 2012 Dec; 21(12):836-40. PubMed ID: 22658887 [Abstract] [Full Text] [Related]
10. [Left ventricular rupture at an atypical place after mitral valve replacement: a case report]. Shinohara M, Fujii N, Kouzu S, Yoshioka J, Akahane K, Tozuka N, Maruyama T. Kyobu Geka; 1993 Feb; 46(2):187-9. PubMed ID: 8437388 [Abstract] [Full Text] [Related]
11. Aortic and mitral valve replacement in children: is there any role for biologic and bioprosthetic substitutes? Alsoufi B, Manlhiot C, McCrindle BW, Canver CC, Sallehuddin A, Al-Oufi S, Joufan M, Al-Halees Z. Eur J Cardiothorac Surg; 2009 Jul; 36(1):84-90; discussion 90. PubMed ID: 19369085 [Abstract] [Full Text] [Related]
12. Risk factors for posterior ventricular rupture after mitral valve replacement: results of 2560 patients. Deniz H, Sokullu O, Sanioglu S, Sargin M, Ozay B, Ayoglu U, Aykut Aka S, Bilgen F. Eur J Cardiothorac Surg; 2008 Oct; 34(4):780-4. PubMed ID: 18621539 [Abstract] [Full Text] [Related]
13. [Case report of bioprosthetic mitral valve malfunction associated with right pulmonary embolism and heart failure]. Jung E, Kou E, Yokoyama S, Naito Y. Kyobu Geka; 2001 Jul; 54(8 Suppl):722-5. PubMed ID: 11517539 [Abstract] [Full Text] [Related]
14. A case of transient bioprosthetic valve regurgitation and hemolysis devoloping early after surgery using Carpentier-Edwards valve. Sezai A, Shiono M, Hata M, Saito A, Hattori T, Wakui S, Soeda M, Kasamaki Y, Tokai K, Saito S, Negishi N, Sezai Y. Ann Thorac Cardiovasc Surg; 2005 Dec; 11(6):413-5. PubMed ID: 16401993 [Abstract] [Full Text] [Related]
15. Long-lasting durability of Carpentier-Edwards pericardial bovine bioprosthesis in mitral position - a case report of unfavourable post redo valve surgery course. Luczak K, Piestrzeniewicz K, Maciejewski M, Walczak A, Jaszewski R, Ostrowski S, Drozdz J. Kardiol Pol; 2010 Jul; 68(7):806-8; discussion 809. PubMed ID: 20648442 [Abstract] [Full Text] [Related]
16. [Mitral valve re-replacement in a patient with occlusion of the left internal carotid artery]. Yoshikai M, Kamohara K, Yunoki J, Fumoto H. Kyobu Geka; 2004 Jan; 57(1):80-2. PubMed ID: 14733104 [Abstract] [Full Text] [Related]
17. [Emergent mitral valve replacement in the second trimester of pregnancy]. Sudoh Y, Takahara Y, Sunazawa T, Satoh T, Ishikawa H. Nihon Kyobu Geka Gakkai Zasshi; 1997 Jul; 45(7):1034-8. PubMed ID: 9256646 [Abstract] [Full Text] [Related]
18. [A case of failure of mitroflow pericardial valve with severe hemolytic anemia]. Ohkado A, Akiyama K, Hirota J, Shiina Y. Kyobu Geka; 1995 Nov; 48(12):1013-5. PubMed ID: 8538101 [Abstract] [Full Text] [Related]
19. Bioprosthetic mitral valve dysfunction due to native valve preserving procedure. Matsuno Y, Mori Y, Umeda Y, Takiya H. Asian Cardiovasc Thorac Ann; 2016 Mar; 24(3):276-9. PubMed ID: 25392048 [Abstract] [Full Text] [Related]
20. Fracture of the wire stent in a Carpentier-Edwards porcine bioprosthesis. Griffin S, Bouboulis N, Holden MP. J Heart Valve Dis; 1993 May; 2(3):357-8. PubMed ID: 8269133 [Abstract] [Full Text] [Related] Page: [Next] [New Search]