These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
216 related items for PubMed ID: 15939565
1. An assessment of calibration and performance of the microdialysis system. Abrahamsson P, Winsö O. J Pharm Biomed Anal; 2005 Sep 15; 39(3-4):730-4. PubMed ID: 15939565 [Abstract] [Full Text] [Related]
2. Urea as an endogenous surrogate in human microdialysis to determine relative recovery of drugs: analytics and applications. Schwalbe O, Buerger C, Plock N, Joukhadar C, Kloft C. J Pharm Biomed Anal; 2006 Apr 11; 41(1):233-9. PubMed ID: 16364587 [Abstract] [Full Text] [Related]
3. Assessment of in vitro and in vivo recovery of sinomenine using microdialysis. Zheng H, Shi LF, Hu JH. Skin Res Technol; 2007 Aug 11; 13(3):323-9. PubMed ID: 17610655 [Abstract] [Full Text] [Related]
5. Urea as a recovery marker for quantitative assessment of tumor interstitial solutes with microdialysis. Ettinger SN, Poellmann CC, Wisniewski NA, Gaskin AA, Shoemaker JS, Poulson JM, Dewhirst MW, Klitzman B. Cancer Res; 2001 Nov 01; 61(21):7964-70. PubMed ID: 11691820 [Abstract] [Full Text] [Related]
6. Validation of the 'internal reference technique' for calibrating microdialysis catheters in situ. Lönnroth P, Strindberg L. Acta Physiol Scand; 1995 Apr 01; 153(4):375-80. PubMed ID: 7618484 [Abstract] [Full Text] [Related]
7. Use of an intraluminal guide wire in linear microdialysis probes: effect on recovery? Klimowicz A, Bielecka-Grzela S, Groth L, Benfeldt E. Skin Res Technol; 2004 May 01; 10(2):104-8. PubMed ID: 15059177 [Abstract] [Full Text] [Related]
8. Serial lactate measurements using microdialysis of interstitial fluid do not correlate with plasma lactate in children after cardiac surgery. van den Heuvel I, Vlasselaers D, Wouters PJ, Milants I, Ellger B, Vanhorebeek I, Van den Berghe G. Pediatr Crit Care Med; 2009 Jan 01; 10(1):66-70. PubMed ID: 19057429 [Abstract] [Full Text] [Related]
9. Method for improved accuracy in endogenous urea recovery marker calibrations for microdialysis in tumors. Sorg BS, Peltz CD, Klitzman B, Dewhirst MW. J Pharmacol Toxicol Methods; 2005 Jan 01; 52(3):341-9. PubMed ID: 15996879 [Abstract] [Full Text] [Related]
10. Intracerebral microdialysis in neurosurgical intensive care patients utilising catheters with different molecular cut-off (20 and 100 kD). Hillman J, Milos P, Yu ZQ, Sjögren F, Anderson C, Mellergård P. Acta Neurochir (Wien); 2006 Mar 01; 148(3):319-24; discussion 324. PubMed ID: 16411015 [Abstract] [Full Text] [Related]
11. Measuring drug concentrations using pulsatile microdialysis: theory and method development in vitro. Kabir MA, Taft DR, Joseph CK, Bellantone RA. Int J Pharm; 2005 Apr 11; 293(1-2):171-82. PubMed ID: 15778055 [Abstract] [Full Text] [Related]
12. In vivo time-course changes in ethanol levels sampled with subcutaneous microdialysis. Engleman EA, Ingraham CM, Franklin KM, Keith CM, McClaren JA, Schultz JA, Morzorati SL, O'Connor S, Thielen RJ, Murphy JM, McBride WJ. Alcohol Clin Exp Res; 2008 Mar 11; 32(3):435-42. PubMed ID: 18215218 [Abstract] [Full Text] [Related]
13. Development of a novel HPLC-MS/MS method for the determination of aconitine and its application to in vitro and rat microdialysis samples. Zhang QL, Hu JH, Zhu QG, Li FQ, Liu JY, Wang D. Biomed Chromatogr; 2009 Jul 11; 23(7):692-9. PubMed ID: 19309751 [Abstract] [Full Text] [Related]
14. Optimised sample handling in association with use of the CMA 600 analyser. Abrahamsson P, Johansson G, Aberg AM, Haney M, Winsö O. J Pharm Biomed Anal; 2008 Nov 04; 48(3):940-5. PubMed ID: 18809273 [Abstract] [Full Text] [Related]
15. [Monitoring of glucose concentration in critical patients, comparing arterial blood glucose concentrations and interstitial glucose concentration measured by microdialysis technique]. Kremen J, Bláha J, Matias M, Anderlová K, Ellmerer M, Plank J, Pieber T, Svacina S, Haluzík M. Vnitr Lek; 2006 Sep 04; 52(9):777-81. PubMed ID: 17091600 [Abstract] [Full Text] [Related]
16. Validation of an endogenous reference technique for the calibration of microdialysis catheters. Strindberg L, Lönnroth P. Scand J Clin Lab Invest; 2000 May 04; 60(3):205-11. PubMed ID: 10885492 [Abstract] [Full Text] [Related]
17. Impact of cardiopulmonary bypass on peripheral tissue metabolism and microvascular blood flow. Mandak J, Pojar M, Cibicek N, Lonsky V, Palicka V, Kakrdova D, Nedvidkova J, Kubicek J, Zivny P. Perfusion; 2008 Nov 04; 23(6):339-46. PubMed ID: 19454562 [Abstract] [Full Text] [Related]