These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
593 related items for PubMed ID: 15975367
21. Left ventricular remodeling, hemodynamics and early clinical outcomes after aortic valve replacement with the Pericarbon Freedom stentless bioprosthesis: results from the Italian Prospective Multicenter Trial. D'Onofrio A, Mazzucco A, Valfrè C, Zussa C, Martinelli L, Casabona R, Mazzola A, Gherli T, Badano LP, Fabbri A. J Heart Valve Dis; 2011 Sep; 20(5):531-9. PubMed ID: 22066357 [Abstract] [Full Text] [Related]
22. Clinical and hemodynamic evaluation of 21 mm and 23 mm Cryolife-O'Brien stentless bioprostheses implanted in the aortic position. Gelsomino S, Frassani R, Porreca L, Morocutti G, Livi U. Ital Heart J; 2000 Sep; 1(9):613-20. PubMed ID: 11130840 [Abstract] [Full Text] [Related]
23. Survival after stentless and stented xenograft aortic valve replacement: a concurrent, case-match trial. Casali G, Auriemma S, Santini F, Mazzucco A, Luciani GB. Ital Heart J; 2004 Apr; 5(4):282-9. PubMed ID: 15185887 [Abstract] [Full Text] [Related]
24. CryoLife-O'Brien stentless valve: 10-year results of 402 implants. O'Brien MF, Gardner MA, Garlick B, Jalali H, Gordon JA, Whitehouse SL, Strugnell WE, Slaughter R. Ann Thorac Surg; 2005 Mar; 79(3):757-66. PubMed ID: 15734372 [Abstract] [Full Text] [Related]
25. Aortic valve replacement with a stentless bioprosthesis using the full-root technique. Wendler O, Dzindzibadze V, Langer F, El Dsoki S, Schäfers HJ. Thorac Cardiovasc Surg; 2001 Dec; 49(6):361-4. PubMed ID: 11745060 [Abstract] [Full Text] [Related]
26. Long-term results after aortic valve replacement with the Bravo 400 stentless xenograft. Polvani G, Barili F, Dainese L, Muratori M, Porqueddu M, Sala A, Biglioli P. Ann Thorac Surg; 2005 Aug; 80(2):495-501. PubMed ID: 16039192 [Abstract] [Full Text] [Related]
28. Midterm outcome after aortic root replacement with stentless porcine bioprostheses. Ennker IC, Albert A, Dalladaku F, Rosendahl U, Ennker J, Florath I. Eur J Cardiothorac Surg; 2011 Aug; 40(2):429-34. PubMed ID: 21277220 [Abstract] [Full Text] [Related]
29. Is routine use of stentless aortic prostheses justified in an elderly (aged > or =75 years) population? Ali A, Kumar P, Athanasiou T, Halstead J, Ashrafian H, Ali Z, Kumar S, Theodorou P, Pepper JR. J Heart Valve Dis; 2005 Jan; 14(1):64-70; discussion 70-1. PubMed ID: 15700438 [Abstract] [Full Text] [Related]
30. Impact of high transvalvular to subvalvular velocity ratio early after aortic valve replacement with Freestyle stentless aortic bioprosthesis. Bach DS, Cartier PA, Kon N, Johnson KG, Dumesnil JG, Doty DB, Freestyle Valve Study Group. Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):75-81. PubMed ID: 11805953 [Abstract] [Full Text] [Related]
31. A single center experience with the freestyle bioprosthesis: midterm results at the Québec Heart Institute. Dagenais F, Cartier P, Dumesnil JG, Pibarot P, Lemieux M, Raymond G, Desaulniers D, Perron J, Bauset R, Baillot R, Doyle D. Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):156-62. PubMed ID: 11805965 [Abstract] [Full Text] [Related]
32. Early postoperative outcome and hemodynamic performance of the sorin pericarbon stentless aortic valve. Bonacchi M, Giunti G, Prifti E, Rostagno C, Bini M, Frati G, Sani G. J Heart Valve Dis; 2002 Sep; 11(5):703-9. PubMed ID: 12358408 [Abstract] [Full Text] [Related]
33. Stentless bioprostheses improve postoperative coronary flow more than stented prostheses after valve replacement for aortic stenosis. Bakhtiary F, Schiemann M, Dzemali O, Wittlinger T, Doss M, Ackermann H, Moritz A, Kleine P. J Thorac Cardiovasc Surg; 2006 Apr; 131(4):883-8. PubMed ID: 16580448 [Abstract] [Full Text] [Related]
34. Stentless aortic valve replacement with the biocor prosthesis: indications and outcome. Achtelik M, Pethig K, Schäfers HJ, Borst HG. J Heart Valve Dis; 1996 Nov; 5 Suppl 3():S314-6. PubMed ID: 8953460 [Abstract] [Full Text] [Related]
35. Are stentless valves hemodynamically superior to stented valves? Long-term follow-up of a randomized trial comparing Carpentier-Edwards pericardial valve with the Toronto Stentless Porcine Valve. Cohen G, Zagorski B, Christakis GT, Joyner CD, Vincent J, Sever J, Harbi S, Feder-Elituv R, Moussa F, Goldman BS, Fremes SE. J Thorac Cardiovasc Surg; 2010 Apr; 139(4):848-59. PubMed ID: 20080264 [Abstract] [Full Text] [Related]
36. Aortic homograft: a suitable substitute for aortic valve replacement. Talwar S, Mohapatra R, Saxena A, Singh R, Kumar AS. Ann Thorac Surg; 2005 Sep; 80(3):832-8. PubMed ID: 16122437 [Abstract] [Full Text] [Related]
37. An exceedingly low operative mortality given by stentless autologous, homologous, and heterologous aortic valves for aortic valve replacement. O'Brien MF. Semin Thorac Cardiovasc Surg; 1999 Oct; 11(4 Suppl 1):12-7. PubMed ID: 10660160 [Abstract] [Full Text] [Related]
38. Short-term hemodynamic advantages of stentless CryoLife-O'Brien valve over stented bioprostheses for aortic valve replacement. Chatel D, Mica C, Blanchard D, Baud F, Bruere D, Maudiere A, Peycher P. Interact Cardiovasc Thorac Surg; 2006 Oct; 5(5):578-80. PubMed ID: 17670650 [Abstract] [Full Text] [Related]
39. The stentless freestyle bioprosthesis: impact of age over 80 years on quality of life, perioperative, and mid-term outcome. Ennker J, Dalladaku F, Rosendahl U, Ennker IC, Mauser M, Florath I. J Card Surg; 2006 Oct; 21(4):379-85. PubMed ID: 16846417 [Abstract] [Full Text] [Related]
40. Stentless aortic valve reoperations: a surgical challenge. Borger MA, Prasongsukarn K, Armstrong S, Feindel CM, David TE. Ann Thorac Surg; 2007 Sep; 84(3):737-43; discussion 743-4. PubMed ID: 17720369 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]