These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
44. Three years' experience with the sorin pericarbon stentless prosthesis: mid-term results with three different implantation techniques. Nagy ZL, Bodi A, Len A, Balogh I, Peterffy A. J Heart Valve Dis; 2005 Jan; 14(1):72-7. PubMed ID: 15700439 [Abstract] [Full Text] [Related]
46. Mid-term pattern of survival, hemodynamic performance and rate of complications after medtronic freestyle versus homograft full aortic root replacement: results from a prospective randomized trial. Melina G, De Robertis F, Gaer JA, Amrani M, Khaghani A, Yacoub MH. J Heart Valve Dis; 2004 Nov; 13(6):972-5; discussion 975-6. PubMed ID: 15597592 [Abstract] [Full Text] [Related]
47. [Risk of perioperative mortality and complications following biological aortic valve replacement in elderly patients: stented vs. unstented prostheses]. Ennker J, Florath I, Rosendahl U, Bauer S, von Hodenberg E, Ennker IC. Z Kardiol; 2001 Nov; 90 Suppl 6():58-64. PubMed ID: 11826823 [Abstract] [Full Text] [Related]
52. Long-term outcome of the MitroFlow pericardial bioprosthesis in the elderly after aortic valve replacement. Sjögren J, Gudbjartsson T, Thulin LI. J Heart Valve Dis; 2006 Mar; 15(2):197-202. PubMed ID: 16607900 [Abstract] [Full Text] [Related]
53. Analysis of explants and causes of mortality during long-term follow-up of the Toronto stentless porcine valve. Shargall Y, Goldman B, Christakis G, David T, Clinical Investigators of TSVP. Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):106-12. PubMed ID: 11805958 [Abstract] [Full Text] [Related]
54. Seven-year results with the St Jude Medical Silzone mechanical prosthesis. Jamieson WR, Fradet GJ, Abel JG, Janusz MT, Lichtenstein SV, MacNab JS, Stanford EA, Chan F. J Thorac Cardiovasc Surg; 2009 May; 137(5):1109-15.e2. PubMed ID: 19379975 [Abstract] [Full Text] [Related]
59. Coronary insufficiency after stentless aortic root replacement: risk factors and solutions. Kincaid EH, Cordell AR, Hammon JW, Adair SM, Kon ND. Ann Thorac Surg; 2007 Mar; 83(3):964-8; discussion 968. PubMed ID: 17307442 [Abstract] [Full Text] [Related]
60. [Mid-term results of stentless bioprosthesis for aortic valve replacement. Experience in a series of 97 patients]. Hubaut JJ, Baron O, Abi Rached N, al Habash O, Despins P, Duveau D, Michaud JL. Arch Mal Coeur Vaiss; 2001 Apr; 94(4):269-75. PubMed ID: 11387932 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]