1. Falsely elevated cardiac troponin-I in patients with seropositive rheumatoid arthritis. Kenny PR, Finger DR. J Rheumatol; 2005 Jul; 32(7):1258-61. PubMed ID: 15996061 [Abstract] [Full Text] [Related]
2. Serum concentrations of cardiac troponin-I in patients with rheumatoid arthritis, systemic lupus erythematosus, primary Sjogren's syndrome and Graves' disease. Al-Awadhi AM, Olusi S, Hasan EA, Abdullah A. Singapore Med J; 2007 Sep; 48(9):847-9. PubMed ID: 17728967 [Abstract] [Full Text] [Related]
3. False positive elevation of cardiac troponin I in seropositive rheumatoid arthritis. Katwa G, Komatireddy G, Walker SE. J Rheumatol; 2001 Dec; 28(12):2750-1. PubMed ID: 11764229 [Abstract] [Full Text] [Related]
4. Detection of myocardial injury in patients with unstable angina using a novel nanoparticle cardiac troponin I assay: observations from the PROTECT-TIMI 30 Trial. Wilson SR, Sabatine MS, Braunwald E, Sloan S, Murphy SA, Morrow DA. Am Heart J; 2009 Sep; 158(3):386-91. PubMed ID: 19699861 [Abstract] [Full Text] [Related]
5. Positive interference from contrast media in cardiac troponin I immunoassays. Lin CT, Lee HC, Voon WC, Yen HW, Tang MH, Chin TT, Chen WR, Chien WT, Lai WT, Sheu SH. Kaohsiung J Med Sci; 2006 Mar; 22(3):107-13. PubMed ID: 16602274 [Abstract] [Full Text] [Related]
6. Interpretation of high sensitivity cardiac troponin I results: reference to biological variability in patients who present to the emergency room with chest pain: case report series. Wu AH. Clin Chim Acta; 2009 Mar; 401(1-2):170-4. PubMed ID: 19135041 [Abstract] [Full Text] [Related]
7. Troponin I: an update on clinical utility and method standardization. Laurino JP. Ann Clin Lab Sci; 2000 Oct; 30(4):412-21. PubMed ID: 11045766 [Abstract] [Full Text] [Related]
8. Elevated levels of IgM and IgA antibodies to Proteus mirabilis and IgM antibodies to Escherichia coli are associated with early rheumatoid factor (RF)-positive rheumatoid arthritis. Newkirk MM, Goldbach-Mansky R, Senior BW, Klippel J, Schumacher HR, El-Gabalawy HS. Rheumatology (Oxford); 2005 Nov; 44(11):1433-41. PubMed ID: 16091399 [Abstract] [Full Text] [Related]
9. [Differences in cardiac troponin I and T levels measured in asymptomatic hemodialysis patients with last generation immunoassays]. Deléaval P, Descombes E, Magnin JL, Martin PY, Fellay G. Nephrol Ther; 2006 May; 2(2):75-81. PubMed ID: 16895718 [Abstract] [Full Text] [Related]
10. False-positive troponin I measured with the Abbott AxSYM attributed to fibrin interference. Kazmierczak SC, Sekhon H, Richards C. Int J Cardiol; 2005 May 11; 101(1):27-31. PubMed ID: 15860379 [Abstract] [Full Text] [Related]
11. False positive elevation of cardiac troponin I in seropositive rheumatoid arthritis. Bas S, Genevay S, Mensi N. J Rheumatol; 2002 Dec 11; 29(12):2665. PubMed ID: 12465175 [No Abstract] [Full Text] [Related]
12. Diagnostic impact of contemporary biomarker assays for rheumatoid arthritis. Nikolaisen C, Rekvig OP, Nossent HC. Scand J Rheumatol; 2007 Dec 11; 36(2):97-100. PubMed ID: 17476614 [Abstract] [Full Text] [Related]
13. Evaluation of the analytical performance of the advanced method for cardiac troponin I for the AxSYM platform: comparison with the old method and the Access system. Storti S, Prontera C, Parri MS, Iervasi A, Vittorini S, Emdin M, Zucchelli GC, Longombardo G, Migliorini P, Clerico A. Clin Chem Lab Med; 2006 Dec 11; 44(8):1022-9. PubMed ID: 16879072 [Abstract] [Full Text] [Related]
14. Normal plasma levels of cardiac troponin I measured by the high-sensitivity cardiac troponin I access prototype assay and the impact on the diagnosis of myocardial ischemia. Venge P, Johnston N, Lindahl B, James S. J Am Coll Cardiol; 2009 Sep 22; 54(13):1165-72. PubMed ID: 19761938 [Abstract] [Full Text] [Related]
15. New approach to standardisation of human cardiac troponin I (cTnI). Katrukha A, Bereznikova A, Pettersson K. Scand J Clin Lab Invest Suppl; 1999 Sep 22; 230():124-7. PubMed ID: 10389210 [Abstract] [Full Text] [Related]
16. Anti-CCP2 is an adjunct to, not a surrogate for, rheumatoid factor in the diagnosis of rheumatoid arthritis: diagnostic utility of anti-CCP2 antibodies in Egyptian patients with rheumatoid arthritis. Abdel-Nasser AM, Mahmoud MH, El Mansoury TM, Osman AM. Scand J Rheumatol; 2008 Sep 22; 37(5):329-36. PubMed ID: 18666028 [Abstract] [Full Text] [Related]
17. [High titers of rheumatoid factor: clinical significance]. Naranjo Hernández A, Rodríguez González T, Rodríguez-Lozano C, Ojeda Bruno S, Francisco Hernández F, Sánchez-García F, Bilbao Cantarero A. Rev Clin Esp; 1997 Apr 22; 197(4):232-6. PubMed ID: 9254397 [Abstract] [Full Text] [Related]
18. Evaluation of 6 cardiac troponin assays in patients with acute coronary syndrome. Saadeddin SM, Habbab MA, Siddieg HH, Al Seeni MN, Tahery AB, Dafterdar RM. Saudi Med J; 2003 Oct 22; 24(10):1092-7. PubMed ID: 14578975 [Abstract] [Full Text] [Related]
20. Performance of the Advia Centaur second-generation troponin assay TnI-Ultra compared with the first-generation cTnI assay. van de Kerkhof D, Peters B, Scharnhorst V. Ann Clin Biochem; 2008 May 22; 45(Pt 3):316-7. PubMed ID: 18482922 [Abstract] [Full Text] [Related] Page: [Next] [New Search]