These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
241 related items for PubMed ID: 16116880
1. Stentless bioprostheses in small aortic roots: impact of patient-prosthesis mismatch on survival and quality of life. Ennker J, Rosendahl U, Albert A, Dumlu E, Ennker IC, Florath I. J Heart Valve Dis; 2005 Jul; 14(4):523-30. PubMed ID: 16116880 [Abstract] [Full Text] [Related]
6. Influence of patient-prosthesis mismatch on long-term results after aortic valve replacement with a stented bioprosthesis. Frapier JM, Rouvière P, Razcka F, Aymard T, Albat B, Chaptal PA. J Heart Valve Dis; 2002 Jul; 11(4):543-51. PubMed ID: 12150304 [Abstract] [Full Text] [Related]
7. Patient-prosthesis mismatch in elderly patients undergoing aortic valve replacement: impact on quality of life and survival. Urso S, Sadaba R, Vives M, Trujillo J, Beltrame S, Soriano B, Piqueras L, Aldamiz-Echevarria G. J Heart Valve Dis; 2009 May; 18(3):248-55. PubMed ID: 19557978 [Abstract] [Full Text] [Related]
8. Effect of prosthesis-patient mismatch on long-term survival with aortic valve replacement: assessment to 15 years. Jamieson WR, Ye J, Higgins J, Cheung A, Fradet GJ, Skarsgard P, Germann E, Chan F, Lichtenstein SV. Ann Thorac Surg; 2010 Jan; 89(1):51-8; discussion 59. PubMed ID: 20103205 [Abstract] [Full Text] [Related]
9. Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly. Roscitano A, Benedetto U, Sciangula A, Merico E, Barberi F, Bianchini R, Tonelli E, Sinatra R. Eur J Cardiothorac Surg; 2006 Feb; 29(2):139-43. PubMed ID: 16376565 [Abstract] [Full Text] [Related]
10. Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: effect on survival, freedom from heart failure, and left ventricular mass regression. Ruel M, Al-Faleh H, Kulik A, Chan KL, Mesana TG, Burwash IG. J Thorac Cardiovasc Surg; 2006 May; 131(5):1036-44. PubMed ID: 16678587 [Abstract] [Full Text] [Related]
11. Impact of high transvalvular to subvalvular velocity ratio early after aortic valve replacement with Freestyle stentless aortic bioprosthesis. Bach DS, Cartier PA, Kon N, Johnson KG, Dumesnil JG, Doty DB, Freestyle Valve Study Group. Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):75-81. PubMed ID: 11805953 [Abstract] [Full Text] [Related]
12. Prosthesis-patient mismatch after aortic valve replacement: impact of age and body size on late survival. Moon MR, Pasque MK, Munfakh NA, Melby SJ, Lawton JS, Moazami N, Codd JE, Crabtree TD, Barner HB, Damiano RJ. Ann Thorac Surg; 2006 Feb; 81(2):481-8; discussion 489. PubMed ID: 16427836 [Abstract] [Full Text] [Related]
13. Does patient-prosthesis mismatch influence the results of combined aortic valve replacement and coronary bypass grafting? Mrówczyński W, Lutter G, Attmann T, Hoffmann G, Quaden R, Cremer J, Böning A. Kardiol Pol; 2009 Aug; 67(8):865-73. PubMed ID: 19784883 [Abstract] [Full Text] [Related]
16. The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis. Bleiziffer S, Eichinger WB, Wagner I, Guenzinger R, Bauernschmitt R, Lange R. J Heart Valve Dis; 2005 Nov; 14(6):814-21; discussion 821. PubMed ID: 16359064 [Abstract] [Full Text] [Related]
18. Ten-year outcome after aortic valve replacement with the freestyle stentless bioprosthesis. Bach DS, Kon ND, Dumesnil JG, Sintek CF, Doty DB. Ann Thorac Surg; 2005 Aug; 80(2):480-6; discussion 486-7. PubMed ID: 16039189 [Abstract] [Full Text] [Related]
19. Impact of valve prosthesis-patient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis. Kato Y, Suehiro S, Shibata T, Sasaki Y, Hirai H. J Card Surg; 2007 Aug; 22(4):314-9. PubMed ID: 17661773 [Abstract] [Full Text] [Related]
20. [Impact of prosthesis-patient mismatch on the quality of life of elderly patients after aortic valve replacement]. Qian XM, Zhong SZ. Nan Fang Yi Ke Da Xue Xue Bao; 2009 Oct; 29(10):2055-8, 2063. PubMed ID: 19861265 [Abstract] [Full Text] [Related] Page: [Next] [New Search]