These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
218 related items for PubMed ID: 1613584
21. Uptake of technetium-99m-tetrofosmin, technetium-99m-MIBI and thallium-201 in tumor cell lines. Arbab AS, Koizumi K, Toyama K, Araki T. J Nucl Med; 1996 Sep; 37(9):1551-6. PubMed ID: 8790217 [Abstract] [Full Text] [Related]
22. Divergent kinetics of 201Tl and 99mTc-SESTAMIBI in cultured chick ventricular myocytes during ATP depletion. Piwnica-Worms D, Chiu ML, Kronauge JF. Circulation; 1992 Apr; 85(4):1531-41. PubMed ID: 1313342 [Abstract] [Full Text] [Related]
23. Technetium-99m-sestamibi scintigraphy compared with thallium-201 in evaluation of thyroid tumors. Nakahara H, Noguchi S, Murakami N, Hoshi H, Jinnouchi S, Nagamachi S, Ohnishi T, Futami S, Flores LG, Watanabe K. J Nucl Med; 1996 Jun; 37(6):901-4. PubMed ID: 8683308 [Abstract] [Full Text] [Related]
24. Myocardial redistribution of technetium-99m-methoxyisobutyl isonitrile (SESTAMIBI). Li QS, Solot G, Frank TL, Wagner HN, Becker LC. J Nucl Med; 1990 Jun; 31(6):1069-76. PubMed ID: 2140856 [Abstract] [Full Text] [Related]
25. Medullary thyroid carcinoma imaged by Tc-99m MIBI SPECT and Tl-201 chloride/Tc-99m pertechnetate subtraction SPECT. Shih WJ, Stipp V, Magoun S, Ain KB, Pulmano C. Clin Nucl Med; 1996 Mar; 21(3):213-7. PubMed ID: 8846566 [Abstract] [Full Text] [Related]
26. Hexakis (2-methoxy isobutylisonitrile) technetium-99m and thallium-201 chloride: uptake and release in cultured myocardial cells. Maublant JC, Gachon P, Moins N. J Nucl Med; 1988 Jan; 29(1):48-54. PubMed ID: 3335927 [Abstract] [Full Text] [Related]
27. Quantitative planar imaging with technetium-99m methoxyisobutyl isonitrile: comparison of uptake patterns with thallium-201. Sinusas AJ, Beller GA, Smith WH, Vinson EL, Brookeman V, Watson DD. J Nucl Med; 1989 Sep; 30(9):1456-63. PubMed ID: 2671298 [Abstract] [Full Text] [Related]
28. [Double injection of Tc99m-methoxy isobutyl isonitrile in the same session: diagnostic accuracy in tomography compared with that of thallium-201 chloride]. Tartagni F, Dondi M, Maiello L, Fallani F, Antonioli P, Franchi R, Corbelli C, Yun LX, Magnani B. Cardiologia; 1990 Jul; 35(7):581-90. PubMed ID: 2088603 [Abstract] [Full Text] [Related]
29. Perfusion and mechanical analysis with technetium-99m 2-methoxy-isobutyl-isonitrile in a case of dilated cardiomyopathy. Takeda T, Toyama H, Ishikawa N, Masuoka T, Ajisaka R, Iida K, Satoh M, Jin W, Saitou T, Yamanouchi T. Ann Nucl Med; 1992 May; 6(2):103-10. PubMed ID: 1622725 [Abstract] [Full Text] [Related]
30. European multi-centre comparison of thallium 201 and technetium 99m methoxyisobutylisonitrile in ischaemic heart disease. Maisey MN, Lowry A, Bischof-Delaloye A, Fridrich R, Inglese E, Khalil MN, van der Schoot JB. Eur J Nucl Med; 1990 May; 16(12):869-72. PubMed ID: 2209656 [Abstract] [Full Text] [Related]
31. In vitro uptake of technetium-99m-teboroxime in carcinoma cell lines and normal cells: comparison with technetium-99m-sestamibi and thallium-201. Maublant JC, Zhang Z, Rapp M, Ollier M, Michelot J, Veyre A. J Nucl Med; 1993 Nov; 34(11):1949-52. PubMed ID: 8229240 [Abstract] [Full Text] [Related]
32. Technetium-99m-tetrofosmin, technetium-99m-MIBI and thallium-201 uptake in rat myocardial cells. Arbab AS, Koizumi K, Toyama K, Arai T, Araki T. J Nucl Med; 1998 Feb; 39(2):266-71. PubMed ID: 9476934 [Abstract] [Full Text] [Related]
33. Discordant uptake of Tl-201 and Tc-99m MIBI in a patient with follicular adenoma. Erdil TY, Turoğlu HT. Ann Nucl Med; 2000 Apr; 14(2):135-8. PubMed ID: 10830533 [Abstract] [Full Text] [Related]
34. Correlation of technetium-99m MIBI and thallium-201 retention in solitary cold thyroid nodules with postoperative histopathology. Erdil TY, Ozker K, Kabasakal L, Kanmaz B, Sönmezoglu K, Atasoy KC, Turoglu HT, Uslu I, Isitman AT, Onsel C. Eur J Nucl Med; 2000 Jun; 27(6):713-20. PubMed ID: 10901459 [Abstract] [Full Text] [Related]
35. Uptake of technetium-99m-teboroxime in cultured myocardial cells: comparison with thallium-201 and technetium-99m-sestamibi. Maublant JC, Moins N, Gachon P, Renoux M, Zhang Z, Veyre A. J Nucl Med; 1993 Feb; 34(2):255-9. PubMed ID: 8429344 [Abstract] [Full Text] [Related]
36. Comparison of the myocardial distributions of 201Tl and 99Tcm-MIBI on SPECT images. Normand B, Maublant J, d'Agrosa MC, Lusson JR, Cassagnes J, Veyre A. Nucl Med Commun; 1991 May; 12(5):393-6. PubMed ID: 2067744 [Abstract] [Full Text] [Related]
37. [Uptake of Tc-99m hexakis 2-methoxy isobutyl isonitrile in lung or mediastinal lesions by SPECT]. Shirakawa T, Mori Y, Moriya E, Dohi M, Kawakami K, Akiba T, Nagata T. Nihon Igaku Hoshasen Gakkai Zasshi; 1995 Jul; 55(8):587-92. PubMed ID: 7638055 [Abstract] [Full Text] [Related]
38. Clinical experience with Tc-99m MIBI imaging in patients with malignant tumors. Preliminary results and comparison with Tl-201. Aktolun C, Bayhan H, Kir M. Clin Nucl Med; 1992 Mar; 17(3):171-6. PubMed ID: 1611785 [Abstract] [Full Text] [Related]
39. Improved detection of viable myocardium with thallium-201 reinjection in chronic coronary artery disease: comparison with technetium-99m-MIBI imaging. Maurea S, Cuocolo A, Nicolai E, Salvatore M. J Nucl Med; 1994 Apr; 35(4):621-4. PubMed ID: 8151385 [Abstract] [Full Text] [Related]
40. [Comparison between myocardial perfusion scintigraphy with thallium-201 and technetium-99m-Sestamibi (methoxy isobutyl isonitrile) for the detection of coronary atherosclerotic disease]. Taillefer R, Lambert R, Grégoire J, Essiambre R, Phaneuf DC. Union Med Can; 1990 Apr; 119(6):322, 324, 326-9. PubMed ID: 2150134 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]