These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
174 related items for PubMed ID: 16150344
1. Vein and artery growth after anastomosis with vascular closure staple clips vs interrupted polypropylene suture: application in pediatric vascular surgery. Calles-Vázquez Mdel C, Viguera FJ, Sun F, Usón JM, Usón J. J Pediatr Surg; 2005 Sep; 40(9):1428-35. PubMed ID: 16150344 [Abstract] [Full Text] [Related]
2. Vascular closure stapler clips versus polypropylene sutures in end-to-end anastomoses of growing arteries and veins. Calles-Vázquez MC, Usón JM, Viguera FJ, Sun F, Paz JI, Usón-Gargallo J. Ann Vasc Surg; 2005 May; 19(3):320-7. PubMed ID: 15818456 [Abstract] [Full Text] [Related]
3. Growing cava vein anastomosis: comparison of cross-clamping and suture times using VCS metallic clips, interrupted nonabsorbable, or continuous absorbable suturing techniques. Calles-Vázquez MC, Abellán Rubio E, Ayala VC, Usón Gargallo J, Sánchez Margallo FM. Ann Vasc Surg; 2013 Oct; 27(7):947-53. PubMed ID: 23993110 [Abstract] [Full Text] [Related]
4. Heterotopic renal transplantation in piglets using vascular closure stapler metallic clips or conventional suturing techniques: comparison of vessel growth and macroscopical study. Calles-Vázquez MC, Rubio EA, Ayala VC, Gargallo JU, Margallo FM. J Pediatr Surg; 2012 Jul; 47(7):1390-8. PubMed ID: 22813802 [Abstract] [Full Text] [Related]
5. Angiographic, ultrasonographic, and macroscopic assessment of aortic growth after VCS clips, interrupted polypropylene, or running polyglycolic acid anastomosis. Calles-Vázquez MC, Crisóstomo V, Sun F, Usón-Gargallo J. J Pediatr Surg; 2007 Oct; 42(10):1695-702. PubMed ID: 17923198 [Abstract] [Full Text] [Related]
6. Vascular closure stapler clip anastomosis decreases aortic cross-clamping time compared to interrupted nonabsorbable and running absorbable sutures in growing pigs. Calles-Vázquez MC, Viguera FJ, Crisóstomo V, Usón-Gargallo J. Ann Vasc Surg; 2006 Jan; 20(1):35-41. PubMed ID: 16378146 [Abstract] [Full Text] [Related]
7. Vascular clips have no significant effect on the cellular proliferation, intimal changes, or peak systolic velocity at anastomoses in rabbit vein grafts. Caiati JM, Madigan JD, Bhagat G, Benvenisty AI, Nowygrod R, Todd GJ. J Surg Res; 2000 Jul; 92(1):29-35. PubMed ID: 10864478 [Abstract] [Full Text] [Related]
8. End-to-end anastomosis in growing vessels using a novel suturing technique: VCS metallic staples. Carmen Calles M, Lima MA, Crisóstomo V, Usón JM, Usón J. Ann Vasc Surg; 2002 May; 16(3):345-52. PubMed ID: 11957007 [Abstract] [Full Text] [Related]
9. Rapid arterial anastomosis with titanium clips. Pikoulis E, Burris D, Rhee P, Nishibe T, Leppäniemi A, Wherry D, Rich N. Am J Surg; 1998 Jun; 175(6):494-6. PubMed ID: 9645780 [Abstract] [Full Text] [Related]
10. Interrupted nitinol U-Clips versus standard running suture for the central arterial T-graft anastomosis: a prospective randomized study. Bigdeli AK, Kaczmarek I, Eifert S, Beiras-Fernandez A, Kober S, Nikolaou K, Oberhoffer M, Vicol C. Eur J Cardiothorac Surg; 2011 Aug; 40(2):e93-7. PubMed ID: 21530292 [Abstract] [Full Text] [Related]
11. Arterial and venous repair with vascular clips: comparison with suture closure. Leppäniemi A, Wherry D, Pikoulis E, Hufnagel H, Waasdorp C, Fishback N, Rich N. J Vasc Surg; 1997 Jul; 26(1):24-8. PubMed ID: 9240317 [Abstract] [Full Text] [Related]
12. Absorbable suture improves growth of venous anastomoses. Gillinov AM, Lee AW, Redmond JM, Zehr KJ, Jackson L, Davis EA, Hruban RH, Williams GM, Cameron DE. J Vasc Surg; 1992 Nov; 16(5):769-73. PubMed ID: 1433665 [Abstract] [Full Text] [Related]
13. A modified technique of end-to-side microvascular anastomosis for the posterior wall. Nakagawa M, Inoue K, Iida T, Asano T. J Reconstr Microsurg; 2008 Oct; 24(7):475-8. PubMed ID: 18798142 [Abstract] [Full Text] [Related]
14. Five years' world experience with nonpenetrating clips for vascular anastomoses. Zeebregts CJ, Kirsch WM, van den Dungen JJ, Zhu YH, van Schilfgaarde R. Am J Surg; 2004 Jun; 187(6):751-60. PubMed ID: 15191871 [Abstract] [Full Text] [Related]
15. Preservation of endothelial integrity and function in experimental vascular anastomosis with non-penetrating clips. Zeebregts C, van den Dungen J, Buikema H, van der Want J, van Schilfgaarde R. Br J Surg; 2001 Sep; 88(9):1201-8. PubMed ID: 11531868 [Abstract] [Full Text] [Related]
16. Two-suture fish-mouth end-to-side microvascular anastomosis with fibrin glue. Sacak B, Tosun U, Egemen O, Sucu DO, Ozcelik IB, Ugurlu K. J Craniofac Surg; 2012 Jul; 23(4):1120-4. PubMed ID: 22777439 [Abstract] [Full Text] [Related]
17. Can nonpenetrating vascular closure staples and hepatocyte growth factor prevent intimal hyperplasia following ePTFE grafting of the carotid artery in rabbits? Akita M, Takenaka H, Harada M, Li TS, Zhang H, Zempo N, Esato K, Nagano T, Taiji M, Noguchi H. Surg Today; 2002 Jul; 32(7):618-22. PubMed ID: 12111519 [Abstract] [Full Text] [Related]
18. Use of continuous horizontal mattress suture technique in end-to-side microsurgical anastomosis. Başar H, Erol B, Tetik C. Hand Surg; 2012 Jul; 17(3):419-27. PubMed ID: 23061959 [Abstract] [Full Text] [Related]
19. Study comparing sutures and nonpenetrating titanium clips for arteriotomy closure after embolectomy. Pikoulis E, Koronarchis D, Filis K, Leppäniemi A, Papas S, Xiromeritis N, Papalambros E, Bastounis E. Surg Endosc; 2001 Jul; 15(7):726-8. PubMed ID: 11591977 [Abstract] [Full Text] [Related]
20. Anastomoses in the common femoral artery, vascular clips or sutures? A feasibility study. Donker JM, Tijnagel MJ, van Zeeland ML, Veen EJ, van der Laan L. Ann Vasc Surg; 2013 Feb; 27(2):194-8. PubMed ID: 22840340 [Abstract] [Full Text] [Related] Page: [Next] [New Search]