These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
100 related items for PubMed ID: 16291266
1. Real-time detection of nitric oxide isotopes in lung function tests. Heller H, Gäbler R, Schuster KD. Methods Enzymol; 2005; 396():592-7. PubMed ID: 16291266 [Abstract] [Full Text] [Related]
2. Sensitive and isotope selective (14NO/15NO) online detection of nitric oxide by faraday-laser magnetic resonance spectroscopy. Gäbler R, Lehmann J. Methods Enzymol; 2005; 396():54-60. PubMed ID: 16291220 [Abstract] [Full Text] [Related]
3. A rapid and reliable method for NO quantification and 15NO/14NO determination using isotope ratio mass spectrometry: an application for the detection of NO synthesis in propionibacteria. Avice JC, Ourry A, Lainé P, Roland N, Louahlia S, Roussel E, Brookes S, Boucaud J. Rapid Commun Mass Spectrom; 1999; 13(12):1197-200. PubMed ID: 10390862 [Abstract] [Full Text] [Related]
4. Real-time analysis of exhaled breath via resonance-enhanced multiphoton ionization-mass spectrometry with a medium pressure laser ionization source: observed nitric oxide profile. Short LC, Frey R, Benter T. Appl Spectrosc; 2006 Feb; 60(2):217-22. PubMed ID: 16542574 [Abstract] [Full Text] [Related]
5. Time resolved simultaneous detection of 14NO and 15NO via mid-infrared cavity leak-out spectroscopy. Halmer D, von Basum G, Horstjann M, Hering P, Mürtz M. Isotopes Environ Health Stud; 2005 Dec; 41(4):303-11. PubMed ID: 16543186 [Abstract] [Full Text] [Related]
7. [The present and future of the pulmonary function tests. The relationship between respiratory and non-respiratory function]. Kambe M, Kimura T, Kawamoto H, Yamagata M, Yimit D, Nakano Y. Rinsho Byori; 1999 Mar; 47(3):262-7. PubMed ID: 10228392 [Abstract] [Full Text] [Related]
8. Micro gas analyzer measurement of nitric oxide in breath by direct wet scrubbing and fluorescence detection. Toda K, Koga T, Kosuge J, Kashiwagi M, Oguchi H, Arimoto T. Anal Chem; 2009 Aug 15; 81(16):7031-7. PubMed ID: 20337385 [Abstract] [Full Text] [Related]
9. Non-invasive online detection of nitric oxide from plants and some other organisms by mass spectrometry. Conrath U, Amoroso G, Köhle H, Sültemeyer DF. Plant J; 2004 Jun 15; 38(6):1015-22. PubMed ID: 15165192 [Abstract] [Full Text] [Related]
10. Exhaled nitric oxide: an emerging marker of inflammation in respiratory diseases. Habib SS. Saudi Med J; 2008 Dec 15; 29(12):1697-702. PubMed ID: 19082216 [Abstract] [Full Text] [Related]
11. Inhaled nitric oxide does not prevent postpneumonectomy pulmonary edema in pigs. Filaire M, Fadel E, Decante B, Seccatore F, Mazmanian GM, Hervé P. J Thorac Cardiovasc Surg; 2007 Mar 15; 133(3):770-4. PubMed ID: 17320582 [Abstract] [Full Text] [Related]
12. Diffusing capacity for nitric oxide: reference values and dependence on alveolar volume. van der Lee I, Zanen P, Stigter N, van den Bosch JM, Lammers JW. Respir Med; 2007 Jul 15; 101(7):1579-84. PubMed ID: 17229562 [Abstract] [Full Text] [Related]
13. Determination of alveolar-capillary O2 partial pressure gradient by using 15NO. Heller H, Brandt S, Schuster KD. Nitric Oxide; 2005 May 15; 12(3):127-8. PubMed ID: 15797840 [Abstract] [Full Text] [Related]
14. Pulmonary diffusing capacities for oxygen-labeled CO2 and nitric oxide in rabbits. Heller H, Fuchs G, Schuster KD. J Appl Physiol (1985); 1998 Feb 15; 84(2):606-11. PubMed ID: 9475872 [Abstract] [Full Text] [Related]
15. Membrane inlet for mass spectrometric measurement of nitric oxide. Tu C, Swenson ER, Silverman DN. Free Radic Biol Med; 2007 Nov 15; 43(10):1453-7. PubMed ID: 17936190 [Abstract] [Full Text] [Related]
16. Short-term variability of nitric oxide diffusing capacity and its components. Murias JM, Zavorsky GS. Respir Physiol Neurobiol; 2007 Aug 01; 157(2-3):316-25. PubMed ID: 17223391 [Abstract] [Full Text] [Related]
17. Analysis of single-breath profiles of exhaled nitric oxide in children with allergy and asthma: guideline-derived plateau concentrations compared to results of automatic evaluation by two analyzers. Chládková J, Havlínová Z, Chyba T, Krcmová I, Chládek J. J Asthma; 2008 Nov 01; 45(9):820-6. PubMed ID: 18972302 [Abstract] [Full Text] [Related]
18. Detection of nitric oxide in exhaled human breath: exercise and resting determinations. Mantione KJ, Esch T, Stefano GB. Med Sci Monit; 2007 Mar 01; 13(3):MT1-5. PubMed ID: 17325642 [Abstract] [Full Text] [Related]