These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
482 related items for PubMed ID: 16326299
1. Hemodynamic measurements after cardiac surgery: transesophageal Doppler versus pulmonary artery catheter. Sharma J, Bhise M, Singh A, Mehta Y, Trehan N. J Cardiothorac Vasc Anesth; 2005 Dec; 19(6):746-50. PubMed ID: 16326299 [Abstract] [Full Text] [Related]
2. Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device. Jaeggi P, Hofer CK, Klaghofer R, Fodor P, Genoni M, Zollinger A. J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):217-20. PubMed ID: 12698405 [Abstract] [Full Text] [Related]
3. Cardiac output determination from endotracheally measured impedance cardiography: clinical evaluation of endotracheal cardiac output monitor. Maus TM, Reber B, Banks DA, Berry A, Guerrero E, Manecke GR. J Cardiothorac Vasc Anesth; 2011 Oct; 25(5):770-5. PubMed ID: 21354828 [Abstract] [Full Text] [Related]
4. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting. Missant C, Rex S, Wouters PF. Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125 [Abstract] [Full Text] [Related]
5. Clinical validation of pulse contour and pulse wave transit time-based continuous cardiac output analyses in Thai patients undergoing cardiac surgery. Wacharasint P, Kunakorn P, Pankongsap P, Preechanukul R. J Med Assoc Thai; 2014 Jan; 97 Suppl 1():S55-60. PubMed ID: 24855843 [Abstract] [Full Text] [Related]
6. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method. Thonnerieux M, Alexander B, Binet C, Obadia JF, Bastien O, Desebbe O. Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321 [Abstract] [Full Text] [Related]
7. Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output. Bein B, Worthmann F, Tonner PH, Paris A, Steinfath M, Hedderich J, Scholz J. J Cardiothorac Vasc Anesth; 2004 Apr; 18(2):185-9. PubMed ID: 15073709 [Abstract] [Full Text] [Related]
8. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution. Graeser K, Zemtsovski M, Kofoed KF, Winther-Jensen M, Nilsson JC, Kjaergaard J, Møller-Sørensen H. Anesth Analg; 2018 Aug; 127(2):399-407. PubMed ID: 29324489 [Abstract] [Full Text] [Related]
15. The effect of landiolol on hemodynamics and left ventricular function in patients with coronary artery disease. Goto K, Shingu C, Miyamoto S, Miyakawa H, Noguchi T. J Clin Anesth; 2007 Nov; 19(7):523-9. PubMed ID: 18063207 [Abstract] [Full Text] [Related]
16. Cardiac output measurement by bioimpedance and noninvasive pulse contour analysis compared with the continuous pulmonary artery thermodilution technique. Maass SW, Roekaerts PM, Lancé MD. J Cardiothorac Vasc Anesth; 2014 Jun; 28(3):534-9. PubMed ID: 24746334 [Abstract] [Full Text] [Related]
17. Measuring cardiac output during dobutamine infusion after off-pump coronary artery bypass: comparison of transesophageal echo-Doppler and thermodilution. Husedzinović I, Barisin S, Tonković D, Sostarić S. Croat Med J; 2002 Dec; 43(6):680-4. PubMed ID: 12476476 [Abstract] [Full Text] [Related]
19. [Monitoring cardiac output: esophageal doppler vs thermodilution]. Leone D, Servillo G, De Robertis E, Rossano F, Tufano R. Minerva Anestesiol; 1998 Dec; 64(7-8):351-6. PubMed ID: 9796245 [Abstract] [Full Text] [Related]
20. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output. Yamada T, Tsutsui M, Sugo Y, Sato T, Akazawa T, Sato N, Yamashita K, Ishihara H, Takeda J. Anesth Analg; 2012 Jul; 115(1):82-7. PubMed ID: 22467885 [Abstract] [Full Text] [Related] Page: [Next] [New Search]