These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Optimising the incorporation and release of a neurotrophic factor using conducting polypyrrole. Thompson BC, Moulton SE, Ding J, Richardson R, Cameron A, O'Leary S, Wallace GG, Clark GM. J Control Release; 2006 Dec 01; 116(3):285-94. PubMed ID: 17112619 [Abstract] [Full Text] [Related]
6. Dexamethasone electrically controlled release from polypyrrole-coated nanostructured electrodes. Leprince L, Dogimont A, Magnin D, Demoustier-Champagne S. J Mater Sci Mater Med; 2010 Mar 01; 21(3):925-30. PubMed ID: 20143134 [Abstract] [Full Text] [Related]
8. Sustained release of dexamethasone from hydrophilic matrices using PLGA nanoparticles for neural drug delivery. Kim DH, Martin DC. Biomaterials; 2006 May 01; 27(15):3031-7. PubMed ID: 16443270 [Abstract] [Full Text] [Related]
12. Polypyrrole doped with 2 peptide sequences from laminin. Stauffer WR, Cui XT. Biomaterials; 2006 Apr 01; 27(11):2405-13. PubMed ID: 16343612 [Abstract] [Full Text] [Related]
13. Surface modification of neural recording electrodes with conducting polymer/biomolecule blends. Cui X, Lee VA, Raphael Y, Wiler JA, Hetke JF, Anderson DJ, Martin DC. J Biomed Mater Res; 2001 Aug 01; 56(2):261-72. PubMed ID: 11340598 [Abstract] [Full Text] [Related]
15. Electrodeposition of anchored polypyrrole film on microelectrodes and stimulation of cultured cardiac myocytes. Nishizawa M, Nozaki H, Kaji H, Kitazume T, Kobayashi N, Ishibashi T, Abe T. Biomaterials; 2007 Mar 01; 28(8):1480-5. PubMed ID: 17166583 [Abstract] [Full Text] [Related]
16. Doped overoxidized polypyrrole microelectrodes as sensors for the detection of dopamine released from cell populations. Sasso L, Heiskanen A, Diazzi F, Dimaki M, Castillo-León J, Vergani M, Landini E, Raiteri R, Ferrari G, Carminati M, Sampietro M, Svendsen WE, Emnéus J. Analyst; 2013 Jul 07; 138(13):3651-9. PubMed ID: 23628978 [Abstract] [Full Text] [Related]
17. Polypyrrole-coated electrodes for the delivery of charge and neurotrophins to cochlear neurons. Richardson RT, Wise AK, Thompson BC, Flynn BO, Atkinson PJ, Fretwell NJ, Fallon JB, Wallace GG, Shepherd RK, Clark GM, O'Leary SJ. Biomaterials; 2009 May 07; 30(13):2614-24. PubMed ID: 19178943 [Abstract] [Full Text] [Related]
18. Metal/polypyrrole quasi-reference electrode for voltammetry in nonaqueous and aqueous solutions. Ghilane J, Hapiot P, Bard AJ. Anal Chem; 2006 Oct 01; 78(19):6868-72. PubMed ID: 17007508 [Abstract] [Full Text] [Related]