These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


310 related items for PubMed ID: 16376100

  • 1. Use of an electrothermal bipolar tissue sealing system in lung surgery.
    Santini M, Vicidomini G, Baldi A, Gallo G, Laperuta P, Busiello L, Di Marino MP, Pastore V.
    Eur J Cardiothorac Surg; 2006 Feb; 29(2):226-30. PubMed ID: 16376100
    [Abstract] [Full Text] [Related]

  • 2. The utility of a reusable bipolar sealing instrument, BiClamp((R)), for pulmonary resection.
    Sakuragi T, Okazaki Y, Mitsuoka M, Yamasaki F, Masuda M, Mori D, Satoh T, Itoh T.
    Eur J Cardiothorac Surg; 2008 Sep; 34(3):505-9. PubMed ID: 18585050
    [Abstract] [Full Text] [Related]

  • 3. Electrothermal bipolar vessel sealing device LigaSureV for pulmonary artery ligation--burst pressure and clinical experiences in complete video-assisted thoracoscopic major lung resection for lung cancer.
    Tsunezuka Y, Waseda R, Yachi T.
    Interact Cardiovasc Thorac Surg; 2010 Sep; 11(3):229-33. PubMed ID: 20558548
    [Abstract] [Full Text] [Related]

  • 4. Bipolar impedance-controlled sealing of the pulmonary artery with SealSafe G3 electric current: determination of bursting pressures in an ex vivo model.
    Kirschbaum A, Kunz J, Steinfeldt T, Pehl A, Meyer C, Bartsch DK.
    J Surg Res; 2014 Dec; 192(2):611-5. PubMed ID: 25128924
    [Abstract] [Full Text] [Related]

  • 5. Usefulness of vessel-sealing devices for ≤7 mm diameter vessels: a randomized controlled trial for human thoracoscopic lobectomy in primary lung cancer.
    Toishi M, Yoshida K, Agatsuma H, Sakaizawa T, Eguchi T, Saito G, Hashizume M, Hamanaka K, Shiina T.
    Interact Cardiovasc Thorac Surg; 2014 Sep; 19(3):448-55. PubMed ID: 24893872
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. A new tissue-sealing technique using the Ligasure system for nonanatomical pulmonary resection: preliminary results of sutureless and stapleless thoracoscopic surgery.
    Shigemura N, Akashi A, Nakagiri T, Ohta M, Matsuda H.
    Ann Thorac Surg; 2004 Apr; 77(4):1415-8; discussion 1419. PubMed ID: 15063276
    [Abstract] [Full Text] [Related]

  • 9. Safety of a thermal vessel sealer on main pulmonary vessels.
    Lacin T, Batirel HF, Ozer K, Demirutku A, Ahiskali R, Yuksel M.
    Eur J Cardiothorac Surg; 2007 Mar; 31(3):482-5; discussion 485. PubMed ID: 17239609
    [Abstract] [Full Text] [Related]

  • 10. Clinical research on the incision line selection of video-assisted thoracoscopic wedge resection of the lung.
    Wang C.
    Surgeon; 2014 Feb; 12(1):17-25. PubMed ID: 24012436
    [Abstract] [Full Text] [Related]

  • 11. Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomy.
    Manouras A, Lagoudianakis EE, Antonakis PT, Filippakis GM, Markogiannakis H, Kekis PB.
    Head Neck; 2005 Nov; 27(11):959-62. PubMed ID: 16134183
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. Electrothermal bipolar vessel sealing system in axillary dissection: a prospective randomized clinical study.
    Cortadellas T, Córdoba O, Espinosa-Bravo M, Mendoza-Santin C, Rodríguez-Fernández J, Esgueva A, Alvarez-Vinuesa M, Rubio IT, Xercavins J.
    Int J Surg; 2011 Nov; 9(8):636-40. PubMed ID: 21925293
    [Abstract] [Full Text] [Related]

  • 15. [Hemostasis and bleeding control in thyroid surgery using electrothermal system (Ligasure): our experience in 317 patients].
    Ashkenazi D, Mazzawi S, Rakover Y.
    Harefuah; 2006 Aug; 145(8):561-4, 632, 631. PubMed ID: 16983836
    [Abstract] [Full Text] [Related]

  • 16. The use of an electrothermal bipolar tissue sealing system in the management of lung hydatid disease.
    Santini M, Fiorelli A, Milione R, Vicidomini G, Accardo M.
    Interact Cardiovasc Thorac Surg; 2014 Oct; 19(4):690-2. PubMed ID: 24994701
    [Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18. [Use of the bipolar vessel sealing system in lung resection].
    Sugi K, Kaneda Y, Satoh Y, Murakami T.
    Kyobu Geka; 2003 Jul; 56(7):551-4. PubMed ID: 12854462
    [Abstract] [Full Text] [Related]

  • 19. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries.
    Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT.
    Surg Endosc; 2003 Aug; 17(8):1228-30. PubMed ID: 12799888
    [Abstract] [Full Text] [Related]

  • 20. Sutureless open low anterior resection with total mesorectal excision for rectal cancer with the use of the electrothermal bipolar vessel sealing system.
    Manouras A, Filippakis GM, Tsekouras D, Lagoudianakis E, Genetzakis M, Markogiannakis H, Kafiri G, Pararas N, Papanikolaou D, Toutouzas KG, Katsaragakis S.
    Med Sci Monit; 2007 May; 13(5):CR224-30. PubMed ID: 17476194
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 16.