These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
299 related items for PubMed ID: 16441598
1. Evaluation of the enhanced bacterial detection system for screening of contaminated platelets. Fournier-Wirth C, Deschaseaux M, Defer C, Godreuil S, Carrière C, Bertrand X, Tunez V, Schneider T, Coste J, Morel P. Transfusion; 2006 Feb; 46(2):220-4. PubMed ID: 16441598 [Abstract] [Full Text] [Related]
2. Enhancement of a culture-based bacterial detection system (eBDS) for platelet products based on measurement of oxygen consumption. Holme S, McAlister MB, Ortolano GA, Chong C, Cortus MA, Jacobs MR, Yomtovian R, Freundlich LF, Wenz B. Transfusion; 2005 Jun; 45(6):984-93. PubMed ID: 15934998 [Abstract] [Full Text] [Related]
3. Evaluation of BacT/ALERT plastic culture bottles for use in testing pooled whole blood-derived leukoreduced platelet-rich plasma platelets with a single contaminated unit. Brecher ME, Hay SN, Rose AD, Rothenberg SJ. Transfusion; 2005 Sep; 45(9):1512-7. PubMed ID: 16131385 [Abstract] [Full Text] [Related]
4. In-house validation of the BACTEC 9240 blood culture system for detection of bacterial contamination in platelet concentrates. Dunne WM, Case LK, Isgriggs L, Lublin DM. Transfusion; 2005 Jul; 45(7):1138-42. PubMed ID: 15987359 [Abstract] [Full Text] [Related]
5. Detection of bacteria in stored red cell products using a culture-based bacterial detection system. Chen CL, Yu JC, Holme S, Jacobs MR, Yomtovian R, McDonald CP. Transfusion; 2008 Aug; 48(8):1550-7. PubMed ID: 18466178 [Abstract] [Full Text] [Related]
6. Comparison of three bacterial detection methods under routine conditions. Schmidt M, Karakassopoulos A, Burkhart J, Deitenbeck R, Asmus J, Müller TH, Weinauer F, Seifried E, Walther-Wenke G. Vox Sang; 2007 Jan; 92(1):15-21. PubMed ID: 17181586 [Abstract] [Full Text] [Related]
7. Evaluation of the Scansystem method for detection of bacterially contaminated platelets. Jacobs MR, Bajaksouzian S, Windau A, Palavecino EL, Yomtovian R. Transfusion; 2005 Feb; 45(2):265-9. PubMed ID: 15660837 [Abstract] [Full Text] [Related]
8. Comparison between the BACTEC 9240 and the Pall eBDS system for detection of bacterial platelet concentrate contamination. Savini V, Balbinot A, Giancola R, Quaglietta A, Accorsi P, D'Antonio D, Iacone A. Transfusion; 2009 Jun; 49(6):1217-23. PubMed ID: 19389034 [Abstract] [Full Text] [Related]
9. Evaluation of pooled cultures for bacterial detection in whole blood-derived platelets. Ramirez-Arcos S, Goldman M. Transfusion; 2005 Aug; 45(8):1275-9. PubMed ID: 16078912 [Abstract] [Full Text] [Related]
10. Culture-based bacterial detection systems for platelets: the effect of time prior to sampling and duration of incubation required for detection with aerobic culture. Ezuki S, Kawabata K, Kanno T, Ohto H. Transfusion; 2007 Nov; 47(11):2044-9. PubMed ID: 17958533 [Abstract] [Full Text] [Related]
11. Pall eBDS: an enhanced bacterial detection system for screening platelet concentrates. McDonald CP, Pearce S, Wilkins K, Colvin J, Robbins S, Colley L, Taylor J, Barbara JA. Transfus Med; 2005 Aug; 15(4):259-68. PubMed ID: 16101803 [Abstract] [Full Text] [Related]
12. Two-year experience with aerobic culturing of apheresis and whole blood-derived platelets. Kleinman SH, Kamel HT, Harpool DR, Vanderpool SK, Custer B, Wiltbank TB, Nguyen KA, Tomasulo PA. Transfusion; 2006 Oct; 46(10):1787-94. PubMed ID: 17002636 [Abstract] [Full Text] [Related]
13. Evolution of surveillance methods for detection of bacterial contamination of platelets in a university hospital, 1991 through 2004. Yomtovian RA, Palavecino EL, Dysktra AH, Downes KA, Morrissey AM, Bajaksouzian S, Pokorny MA, Lazarus HM, Jacobs MR. Transfusion; 2006 May; 46(5):719-30. PubMed ID: 16686839 [Abstract] [Full Text] [Related]
14. Fatal group C streptococcal infection due to transfusion of a bacterially contaminated pooled platelet unit despite routine bacterial culture screening. Lessa F, Leparc GF, Benson K, Sanderson R, Van Beneden CA, Shewmaker PL, Jensen B, Arduino MJ, Kuehnert MJ. Transfusion; 2008 Oct; 48(10):2177-83. PubMed ID: 18564393 [Abstract] [Full Text] [Related]
15. Bacterial contamination of whole-blood-derived platelets: the introduction of sample diversion and prestorage pooling with culture testing in the American Red Cross. Benjamin RJ, Kline L, Dy BA, Kennedy J, Pisciotto P, Sapatnekar S, Mercado R, Eder AF. Transfusion; 2008 Nov; 48(11):2348-55. PubMed ID: 18657074 [Abstract] [Full Text] [Related]
16. Canadian experience with detection of bacterial contamination in apheresis platelets. Ramírez-Arcos S, Jenkins C, Dion J, Bernier F, Delage G, Goldman M. Transfusion; 2007 Mar; 47(3):421-9. PubMed ID: 17319821 [Abstract] [Full Text] [Related]
17. Bacterial contamination of platelet concentrates: results of a prospective multicenter study comparing pooled whole blood-derived platelets and apheresis platelets. Schrezenmeier H, Walther-Wenke G, Müller TH, Weinauer F, Younis A, Holland-Letz T, Geis G, Asmus J, Bauerfeind U, Burkhart J, Deitenbeck R, Förstemann E, Gebauer W, Höchsmann B, Karakassopoulos A, Liebscher UM, Sänger W, Schmidt M, Schunter F, Sireis W, Seifried E. Transfusion; 2007 Apr; 47(4):644-52. PubMed ID: 17381623 [Abstract] [Full Text] [Related]
18. Development of proficiency testing for detection of bacterial contamination of platelet products. Easley S, Yomtovian RA, Sullivan P, Jacobs MR. Transfusion; 2007 Feb; 47(2):251-5. PubMed ID: 17302771 [Abstract] [Full Text] [Related]
19. Validation of BacT/ALERT plastic culture bottles for use in testing of whole-blood-derived leukoreduced platelet-rich-plasma-derived platelets. Brecher ME, Hay SN, Rothenberg SJ. Transfusion; 2004 Aug; 44(8):1174-8. PubMed ID: 15265121 [Abstract] [Full Text] [Related]
20. The residual risk of sepsis: modeling the effect of concentration on bacterial detection in two-bottle culture systems and an estimation of false-negative culture rates. Benjamin RJ, Wagner SJ. Transfusion; 2007 Aug; 47(8):1381-9. PubMed ID: 17655581 [Abstract] [Full Text] [Related] Page: [Next] [New Search]