These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
179 related items for PubMed ID: 16457772
1. Determination of dopamine in the presence of ascorbic acid by poly(styrene sulfonic acid) sodium salt/single-wall carbon nanotube film modified glassy carbon electrode. Zhang Y, Cai Y, Su S. Anal Biochem; 2006 Mar 15; 350(2):285-91. PubMed ID: 16457772 [Abstract] [Full Text] [Related]
2. DNA/Poly(p-aminobenzensulfonic acid) composite bi-layer modified glassy carbon electrode for determination of dopamine and uric acid under coexistence of ascorbic acid. Lin X, Kang G, Lu L. Bioelectrochemistry; 2007 May 15; 70(2):235-44. PubMed ID: 17079195 [Abstract] [Full Text] [Related]
3. Determination of dopamine in the presence of ascorbic acid using poly(3,5-dihydroxy benzoic acid) film modified electrode. Hou S, Zheng N, Feng H, Li X, Yuan Z. Anal Biochem; 2008 Oct 15; 381(2):179-84. PubMed ID: 18455490 [Abstract] [Full Text] [Related]
4. Highly selective and sensitive determination of dopamine using a Nafion/carbon nanotubes coated poly(3-methylthiophene) modified electrode. Wang HS, Li TH, Jia WL, Xu HY. Biosens Bioelectron; 2006 Dec 15; 22(5):664-9. PubMed ID: 16621509 [Abstract] [Full Text] [Related]
5. Simultaneous determination of dopamine, ascorbic acid and uric acid at poly (Evans Blue) modified glassy carbon electrode. Lin L, Chen J, Yao H, Chen Y, Zheng Y, Lin X. Bioelectrochemistry; 2008 Jun 15; 73(1):11-7. PubMed ID: 18417426 [Abstract] [Full Text] [Related]
6. Poly(4-amino-1-1'-azobenzene-3, 4'-disulfonic acid) coated electrode for selective detection of dopamine from its interferences. Kumar SA, Tang CF, Chen SM. Talanta; 2008 Jan 15; 74(4):860-6. PubMed ID: 18371720 [Abstract] [Full Text] [Related]
7. [Electrochemical behavior of dopamine at the poly (isonicotinic acid) modified glassy carbon electrode]. Zhao H, Zhang YZ, Yuan ZB. Yao Xue Xue Bao; 2002 Jun 15; 37(6):454-7. PubMed ID: 12579805 [Abstract] [Full Text] [Related]
8. [Selective determination of dopamine in the presence of high concentration of ascorbic acid with L-cysteine modified glassy carbon electrodes]. Ma XY, Chao Z, Li X, Xu HY, Zhang GR. Nan Fang Yi Ke Da Xue Xue Bao; 2006 May 15; 26(5):648-50. PubMed ID: 16762874 [Abstract] [Full Text] [Related]
9. Poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) (PEDOT-PANS) film modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid and uric acid. Balamurugan A, Chen SM. Anal Chim Acta; 2007 Jul 16; 596(1):92-8. PubMed ID: 17616245 [Abstract] [Full Text] [Related]
10. Electrochemically selective determination of dopamine in the presence of ascorbic and uric acids on the surface of the modified Nafion/single wall carbon nanotube/poly(3-methylthiophene) glassy carbon electrodes. Quan do P, Tuyen do P, Lam TD, Tram PT, Binh NH, Viet PH. Colloids Surf B Biointerfaces; 2011 Dec 01; 88(2):764-70. PubMed ID: 21907551 [Abstract] [Full Text] [Related]
11. Selective response of dopamine in the presence of ascorbic acid on carbon paste electrode modified with titanium phosphated silica gel. Kooshki M, Shams E. Anal Chim Acta; 2007 Mar 21; 587(1):110-5. PubMed ID: 17386761 [Abstract] [Full Text] [Related]
12. Electrochemical detection of dopamine in the presence of ascorbic acid using graphene modified electrodes. Kim YR, Bong S, Kang YJ, Yang Y, Mahajan RK, Kim JS, Kim H. Biosens Bioelectron; 2010 Jun 15; 25(10):2366-9. PubMed ID: 20307965 [Abstract] [Full Text] [Related]
13. Sodium dodecyl sulfate-modified carbon paste electrodes for selective determination of dopamine in the presence of ascorbic acid. Zheng J, Zhou X. Bioelectrochemistry; 2007 May 15; 70(2):408-15. PubMed ID: 16843072 [Abstract] [Full Text] [Related]
14. Selective response of dopamine in the presence of ascorbic acid at multi-walled carbon nanotube modified gold electrode. Zhang P, Wu FH, Zhao GC, Wei XW. Bioelectrochemistry; 2005 Sep 15; 67(1):109-14. PubMed ID: 15950547 [Abstract] [Full Text] [Related]
15. A novel nanoporous gold modified electrode for the selective determination of dopamine in the presence of ascorbic acid. Qiu HJ, Zhou GP, Ji GL, Zhang Y, Huang XR, Ding Y. Colloids Surf B Biointerfaces; 2009 Feb 15; 69(1):105-8. PubMed ID: 19108998 [Abstract] [Full Text] [Related]
16. Selective determination of dopamine in the presence of high concentration of ascorbic acid using nano-Au self-assembly glassy carbon electrode. Hu GZ, Zhang DP, Wu WL, Yang ZS. Colloids Surf B Biointerfaces; 2008 Apr 01; 62(2):199-205. PubMed ID: 18006287 [Abstract] [Full Text] [Related]
17. Sensitive determination of dopamine in the presence of uric acid and ascorbic acid using TiO2 nanotubes modified with Pd, Pt and Au nanoparticles. Mahshid S, Li C, Mahshid SS, Askari M, Dolati A, Yang L, Luo S, Cai Q. Analyst; 2011 Jun 07; 136(11):2322-9. PubMed ID: 21494708 [Abstract] [Full Text] [Related]
18. Electropolymerized film of functionalized thiadiazole on glassy carbon electrode for the simultaneous determination of ascorbic acid, dopamine and uric acid. Kalimuthu P, John SA. Bioelectrochemistry; 2009 Nov 07; 77(1):13-8. PubMed ID: 19467620 [Abstract] [Full Text] [Related]
19. Electrochemical synthesis of polyaniline nano-networks on p-aminobenzene sulfonic acid functionalized glassy carbon electrode Its use for the simultaneous determination of ascorbic acid and uric acid. Zhang L, Zhang C, Lian J. Biosens Bioelectron; 2008 Dec 01; 24(4):690-5. PubMed ID: 18706798 [Abstract] [Full Text] [Related]
20. Simultaneous voltammetric determination of norepinephrine, ascorbic acid and uric acid on polycalconcarboxylic acid modified glassy carbon electrode. Liu AL, Zhang SB, Chen W, Lin XH, Xia XH. Biosens Bioelectron; 2008 May 15; 23(10):1488-95. PubMed ID: 18289842 [Abstract] [Full Text] [Related] Page: [Next] [New Search]