These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


193 related items for PubMed ID: 16545023

  • 1. Improving performance of HVAC systems to reduce exposure to aerosolized infectious agents in buildings; recommendations to reduce risks posed by biological attacks.
    Hitchcock PJ, Mair M, Inglesby TV, Gross J, Henderson DA, O'Toole T, Ahern-Seronde J, Bahnfleth WP, Brennan T, Burroughs HE, Davidson C, Delp W, Ensor DS, Gomory R, Olsiewski P, Samet JM, Smith WM, Streifel AJ, White RH, Woods JE.
    Biosecur Bioterror; 2006; 4(1):41-54. PubMed ID: 16545023
    [Abstract] [Full Text] [Related]

  • 2. Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions.
    Huang R, Agranovski I, Pyankov O, Grinshpun S.
    Indoor Air; 2008 Apr; 18(2):106-12. PubMed ID: 18333990
    [Abstract] [Full Text] [Related]

  • 3. The effectiveness of stand alone air cleaners for shelter-in-place.
    Ward M, Siegel JA, Corsi RL.
    Indoor Air; 2005 Apr; 15(2):127-34. PubMed ID: 15737155
    [Abstract] [Full Text] [Related]

  • 4. Silver zeolite antimicrobial activity in aluminium heating, ventilation and air conditioning system ducts.
    Rizzetto R, Mansi A, Panatto D, Rizzitelli E, Tinteri C, Sasso T, Gasparini R, Crovari P.
    J Prev Med Hyg; 2008 Mar; 49(1):26-33. PubMed ID: 18792531
    [Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6. Detection of viruses in used ventilation filters from two large public buildings.
    Goyal SM, Anantharaman S, Ramakrishnan MA, Sajja S, Kim SW, Stanley NJ, Farnsworth JE, Kuehn TH, Raynor PC.
    Am J Infect Control; 2011 Sep; 39(7):e30-8. PubMed ID: 21549446
    [Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 9. Transport of Bacillus thuringiensis var. kurstaki from an outdoor release into buildings: pathways of infiltration and a rapid method to identify contaminated buildings.
    Van Cuyk S, Deshpande A, Hollander A, Franco DO, Teclemariam NP, Layshock JA, Ticknor LO, Brown MJ, Omberg KM.
    Biosecur Bioterror; 2012 Jun; 10(2):215-27. PubMed ID: 22676846
    [Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.
    Ackelsberg J, Leykam FM, Hazi Y, Madsen LC, West TH, Faltesek A, Henderson GD, Henderson CL, Leighton T.
    Biosecur Bioterror; 2011 Sep; 9(3):213-24. PubMed ID: 21793731
    [Abstract] [Full Text] [Related]

  • 12. Air cleaners: a review.
    Fox RW.
    J Allergy Clin Immunol; 1994 Aug; 94(2 Pt 2):413-6. PubMed ID: 8077600
    [Abstract] [Full Text] [Related]

  • 13. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].
    Bellucci Sessa R, Riccio G.
    G Ital Med Lav Ergon; 2004 Aug; 26(4):375-81. PubMed ID: 15584448
    [Abstract] [Full Text] [Related]

  • 14. Cabin air filtration: helping to protect occupants from infectious diseases.
    Bull K.
    Travel Med Infect Dis; 2008 May; 6(3):142-4. PubMed ID: 18486070
    [Abstract] [Full Text] [Related]

  • 15. Effect of heating-ventilation-air conditioning system sanitation on airborne fungal populations in residential environments.
    Garrison RA, Robertson LD, Koehn RD, Wynn SR.
    Ann Allergy; 1993 Dec; 71(6):548-56. PubMed ID: 8267249
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. Germicidal ultraviolet irradiation in air conditioning systems: effect on office worker health and wellbeing: a pilot study.
    Menzies D, Pasztor J, Rand T, Bourbeau J.
    Occup Environ Med; 1999 Jun; 56(6):397-402. PubMed ID: 10474536
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 10.