These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
1266 related items for PubMed ID: 16545702
1. Complications after zygoma fracture fixation: is there a difference between biodegradable materials and how do they compare with titanium osteosynthesis? Wittwer G, Adeyemo WL, Yerit K, Voracek M, Turhani D, Watzinger F, Enislidis G. Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2006 Apr; 101(4):419-25. PubMed ID: 16545702 [Abstract] [Full Text] [Related]
2. Fixation of zygomatic fractures with a biodegradable copolymer osteosynthesis system: short- and long-term results. Enislidis G, Lagogiannis G, Wittwer G, Glaser C, Ewers R. Int J Oral Maxillofac Surg; 2005 Jan; 34(1):19-26. PubMed ID: 15617962 [Abstract] [Full Text] [Related]
4. An evaluation of the clinical application of three different biodegradable osteosynthesis materials for the fixation of zygomatic fractures. Wittwer G, Adeyemo WL, Voracek M, Turhani D, Ewers R, Watzinger F, Enislidis G. Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2005 Dec; 100(6):656-60. PubMed ID: 16301144 [Abstract] [Full Text] [Related]
8. Tissue response to poly-L-lactide acid-polyglycolic acid absorbable screws in autogenous bone grafts: a histologic morphological analysis. Matsumoto MA, Filho HN, Padovan LE, Kawakami RY, De Assis Taveira LA. Clin Oral Implants Res; 2005 Feb; 16(1):112-8. PubMed ID: 15642038 [Abstract] [Full Text] [Related]
9. The use of biodegradable plates and screws to stabilize facial fractures. Bell RB, Kindsfater CS. J Oral Maxillofac Surg; 2006 Jan; 64(1):31-9. PubMed ID: 16360854 [Abstract] [Full Text] [Related]
10. Rigid internal fixation with titanium versus bioresorbable miniplates in the repair of mandibular fractures in rabbits. Hochuli-Vieira E, Cabrini Gabrielli MA, Pereira-Filho VA, Gabrielli MF, Padilha JG. Int J Oral Maxillofac Surg; 2005 Mar; 34(2):167-73. PubMed ID: 15695046 [Abstract] [Full Text] [Related]
17. The efficacy of bioresorbable fixation in the repair of mandibular fractures: an animal study. Quereshy FA, Goldstein JA, Goldberg JS, Beg Z. J Oral Maxillofac Surg; 2000 Nov; 58(11):1263-9. PubMed ID: 11078138 [Abstract] [Full Text] [Related]
18. Delayed infection after a zygoma fracture fixation with absorbable plates. Lee JH, Chang JW, Choi MS, Ahn HC. J Craniofac Surg; 2010 Nov; 21(6):2018-9. PubMed ID: 21119490 [Abstract] [Full Text] [Related]
19. Comparison of biodegradable and titanium fixation systems in maxillofacial surgery: a two-year multi-center randomized controlled trial. van Bakelen NB, Buijs GJ, Jansma J, de Visscher JG, Hoppenreijs TJ, Bergsma JE, Stegenga B, Bos RR. J Dent Res; 2013 Dec; 92(12):1100-5. PubMed ID: 24130219 [Abstract] [Full Text] [Related]