These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
403 related items for PubMed ID: 16690491
1. Quantification of serum 25-hydroxyvitamin D(2) and D(3) using HPLC-tandem mass spectrometry and examination of reference intervals for diagnosis of vitamin D deficiency. Saenger AK, Laha TJ, Bremner DE, Sadrzadeh SM. Am J Clin Pathol; 2006 Jun; 125(6):914-20. PubMed ID: 16690491 [Abstract] [Full Text] [Related]
2. Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method. Chen H, McCoy LF, Schleicher RL, Pfeiffer CM. Clin Chim Acta; 2008 May; 391(1-2):6-12. PubMed ID: 18279671 [Abstract] [Full Text] [Related]
3. Determination of serum vitamins 25-OH-D2 and 25-OH-D3 with liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization or electrospray source and core-shell or sub-2 μm particle columns: a comparative study. Bogusz MJ, Al Enazi E, Tahtamoni M, Jawaad JA, Al Tufail M. Clin Biochem; 2011 Nov; 44(16):1329-37. PubMed ID: 21907190 [Abstract] [Full Text] [Related]
4. Quantification of urinary 8-iso-PGF2alpha using liquid chromatography-tandem mass spectrometry and association with elevated troponin levels. Saenger AK, Laha TJ, Edenfield MJ, Sadrzadeh SM. Clin Biochem; 2007 Nov; 40(16-17):1297-304. PubMed ID: 17854792 [Abstract] [Full Text] [Related]
5. A simple automated solid-phase extraction procedure for measurement of 25-hydroxyvitamin D3 and D2 by liquid chromatography-tandem mass spectrometry. Knox S, Harris J, Calton L, Wallace AM. Ann Clin Biochem; 2009 May; 46(Pt 3):226-30. PubMed ID: 19389886 [Abstract] [Full Text] [Related]
6. Simultaneous determination of Delta9-tetrahydrocannabinol, 11-hydroxy-Delta9-tetrahydrocannabinol and 11-nor-9-carboxy- Delta9-tetrahydrocannabinol in human plasma by high-performance liquid chromatography/tandem mass spectrometry. Maralikova B, Weinmann W. J Mass Spectrom; 2004 May; 39(5):526-31. PubMed ID: 15170748 [Abstract] [Full Text] [Related]
7. High-throughput liquid-liquid extraction and LCMSMS assay for determination of circulating 25(OH) vitamin D3 and D2 in the routine clinical laboratory. Højskov CS, Heickendorff L, Møller HJ. Clin Chim Acta; 2010 Jan; 411(1-2):114-6. PubMed ID: 19850018 [Abstract] [Full Text] [Related]
8. Rapid analysis of 25-hydroxyvitamin D(2) and D(3) by liquid chromatography-tandem mass spectrometry and association of vitamin D and parathyroid hormone concentrations in healthy adults. Kushnir MM, Ray JA, Rockwood AL, Roberts WL, La'ulu SL, Whittington JE, Meikle AW. Am J Clin Pathol; 2010 Jul; 134(1):148-56. PubMed ID: 20551279 [Abstract] [Full Text] [Related]
9. A specific LC/ESI-MS/MS method for determination of 25-hydroxyvitamin D3 in neonatal dried blood spots containing a potential interfering metabolite, 3-epi-25-hydroxyvitamin D3. Higashi T, Suzuki M, Hanai J, Inagaki S, Min JZ, Shimada K, Toyo'oka T. J Sep Sci; 2011 Apr; 34(7):725-32. PubMed ID: 21328697 [Abstract] [Full Text] [Related]
10. Simultaneous quantification of four vitamin D metabolites in human serum using high performance liquid chromatography tandem mass spectrometry for vitamin D profiling. Baecher S, Leinenbach A, Wright JA, Pongratz S, Kobold U, Thiele R. Clin Biochem; 2012 Nov; 45(16-17):1491-6. PubMed ID: 22771503 [Abstract] [Full Text] [Related]
11. Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry. Turpeinen U, Linko S, Itkonen O, Hämäläinen E. Scand J Clin Lab Invest; 2008 Nov; 68(1):50-7. PubMed ID: 17852804 [Abstract] [Full Text] [Related]
12. Isotope dilution ultra performance liquid chromatography-tandem mass spectrometry method for simultaneous measurement of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in human serum. Schleicher RL, Encisco SE, Chaudhary-Webb M, Paliakov E, McCoy LF, Pfeiffer CM. Clin Chim Acta; 2011 Aug 17; 412(17-18):1594-9. PubMed ID: 21601563 [Abstract] [Full Text] [Related]
13. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum. van den Ouweland JM, Beijers AM, van Daal H. J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Sep 15; 967():195-202. PubMed ID: 25125396 [Abstract] [Full Text] [Related]
14. Simultaneous analysis of THC and its metabolites in blood using liquid chromatography-tandem mass spectrometry. Del Mar Ramirez Fernandez M, De Boeck G, Wood M, Lopez-Rivadulla M, Samyn N. J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Nov 15; 875(2):465-70. PubMed ID: 18922747 [Abstract] [Full Text] [Related]
15. Inappropriate serum levels of retinol, alpha-tocopherol, 25 hydroxyvitamin D3 and 24,25 dihydroxyvitamin D3 levels in healthy Spanish adults: simultaneous assessment by HPLC. Mata-Granados JM, Luque de Castro MD, Quesada Gomez JM. Clin Biochem; 2008 Jun 15; 41(9):676-80. PubMed ID: 18313404 [Abstract] [Full Text] [Related]
16. Current assays overestimate 25-hydroxyvitamin D3 and underestimate 25-hydroxyvitamin D2 compared with HPLC: need for assay-specific decision limits and metabolite-specific assays. Glendenning P, Taranto M, Noble JM, Musk AA, Hammond C, Goldswain PR, Fraser WD, Vasikaran SD. Ann Clin Biochem; 2006 Jan 15; 43(Pt 1):23-30. PubMed ID: 16390606 [Abstract] [Full Text] [Related]
17. Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma. Zhang SW, Jian W, Sullivan S, Sankaran B, Edom RW, Weng N, Sharkey D. J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun 15; 961():62-70. PubMed ID: 24861873 [Abstract] [Full Text] [Related]
18. Analysis and quantification of vitamin D metabolites in serum by ultra-performance liquid chromatography coupled to tandem mass spectrometry and high-resolution mass spectrometry--a method comparison and validation. Bruce SJ, Rochat B, Béguin A, Pesse B, Guessous I, Boulat O, Henry H. Rapid Commun Mass Spectrom; 2013 Jan 15; 27(1):200-6. PubMed ID: 23239334 [Abstract] [Full Text] [Related]
19. Vitamin D and its metabolites--supply of patients with various endocrine disorders and comparison of analytical methods. Vosatkova M, Hoskovcova P, Bilek R. Endocr Regul; 2007 Mar 15; 41(1):19-28. PubMed ID: 17437341 [Abstract] [Full Text] [Related]
20. Measurement of urinary free cortisol using liquid chromatography-tandem mass spectrometry: comparison with the urine adapted ACS:180 serum cortisol chemiluminescent immunoassay and development of a new reference range. McCann SJ, Gillingwater S, Keevil BG. Ann Clin Biochem; 2005 Mar 15; 42(Pt 2):112-8. PubMed ID: 15829119 [Abstract] [Full Text] [Related] Page: [Next] [New Search]