These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
153 related items for PubMed ID: 16714819
1. Evaluation of charge-injection devices for use in laue diffraction imaging. Hanley QS, True JB, Denton MB. J Synchrotron Radiat; 1995 Sep 01; 2(Pt 5):215-28. PubMed ID: 16714819 [Abstract] [Full Text] [Related]
2. Energy resolution of the CdTe-XPAD detector: calibration and potential for Laue diffraction measurements on protein crystals. Medjoubi K, Thompson A, Bérar JF, Clemens JC, Delpierre P, Da Silva P, Dinkespiler B, Fourme R, Gourhant P, Guimaraes B, Hustache S, Idir M, Itié JP, Legrand P, Menneglier C, Mercere P, Picca F, Samama JP. J Synchrotron Radiat; 2012 May 01; 19(Pt 3):323-31. PubMed ID: 22514165 [Abstract] [Full Text] [Related]
3. A foil-mask spectrometer for laue pattern imaging: simultaneous position, intensity and energy. Hanley QS, Dunphy DR, Denton MB. J Synchrotron Radiat; 1996 May 01; 3(Pt 3):101-11. PubMed ID: 16702667 [Abstract] [Full Text] [Related]
4. Charge-injection-device performance in the high-energy-neutron environment of laser-fusion experiments. Marshall FJ, DeHaas T, Glebov VY. Rev Sci Instrum; 2010 Oct 01; 81(10):10E503. PubMed ID: 21034031 [Abstract] [Full Text] [Related]
8. Invited article: the fast readout low noise camera as a versatile x-ray detector for time resolved dispersive extended x-ray absorption fine structure and diffraction studies of dynamic problems in materials science, chemistry, and catalysis. Labiche JC, Mathon O, Pascarelli S, Newton MA, Ferre GG, Curfs C, Vaughan G, Homs A, Carreiras DF. Rev Sci Instrum; 2007 Sep 01; 78(9):091301. PubMed ID: 17902940 [Abstract] [Full Text] [Related]
9. A tunable multicolour 'rainbow' filter for improved stress and dislocation density field mapping in polycrystals using X-ray Laue microdiffraction. Robach O, Micha JS, Ulrich O, Geaymond O, Sicardy O, Härtwig J, Rieutord F. Acta Crystallogr A; 2013 Mar 01; 69(Pt 2):164-70. PubMed ID: 23403967 [Abstract] [Full Text] [Related]
10. Detectors for the future of X-ray imaging. Aslund M, Fredenberg E, Telman M, Danielsson M. Radiat Prot Dosimetry; 2010 Mar 01; 139(1-3):327-33. PubMed ID: 20207749 [Abstract] [Full Text] [Related]
11. K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors. Roessl E, Proksa R. Phys Med Biol; 2007 Aug 07; 52(15):4679-96. PubMed ID: 17634657 [Abstract] [Full Text] [Related]
12. Single-shot full strain tensor determination with microbeam X-ray Laue diffraction and a two-dimensional energy-dispersive detector. Abboud A, Kirchlechner C, Keckes J, Conka Nurdan T, Send S, Micha JS, Ulrich O, Hartmann R, Strüder L, Pietsch U. J Appl Crystallogr; 2017 Jun 01; 50(Pt 3):901-908. PubMed ID: 28656042 [Abstract] [Full Text] [Related]