These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
353 related items for PubMed ID: 16870223
1. Experimental three dimensional strain estimation from ultrasonic sectorial data. Said G, Basset O, Mari JM, Cachard C, Brusseau E, Vray D. Ultrasonics; 2006 Dec 22; 44 Suppl 1():e189-93. PubMed ID: 16870223 [Abstract] [Full Text] [Related]
2. Elasticity reconstruction for ultrasound elastography using a radial compression: an inverse approach. Luo J, Ying K, Bai J. Ultrasonics; 2006 Dec 22; 44 Suppl 1():e195-8. PubMed ID: 16854445 [Abstract] [Full Text] [Related]
3. Angular strain estimation method for elastography. Bae U, Kim Y. IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Dec 22; 54(12):2653-61. PubMed ID: 18276572 [Abstract] [Full Text] [Related]
4. Ultrasound frame rate requirements for cardiac elastography: experimental and in vivo results. Chen H, Varghese T, Rahko PS, Zagzebski JA. Ultrasonics; 2009 Jan 22; 49(1):98-111. PubMed ID: 18657839 [Abstract] [Full Text] [Related]
5. Assessing image quality in effective Poisson's ratio elastography and poroelastography: I. Righetti R, Srinivasan S, Kumar AT, Ophir J, Krouskop TA. Phys Med Biol; 2007 Mar 07; 52(5):1303-20. PubMed ID: 17301456 [Abstract] [Full Text] [Related]
6. Resolution of axial shear strain elastography. Thitaikumar A, Righetti R, Krouskop TA, Ophir J. Phys Med Biol; 2006 Oct 21; 51(20):5245-57. PubMed ID: 17019036 [Abstract] [Full Text] [Related]
7. Transient displacement induced in shear wave elastography: comparison between analytical results and ultrasound measurements. Elkateb Hachemi M, Callé S, Remenieras JP. Ultrasonics; 2006 Dec 22; 44 Suppl 1():e221-5. PubMed ID: 16843510 [Abstract] [Full Text] [Related]
8. An efficient sound speed estimation method to enhance image resolution in ultrasound imaging. Cho MH, Kang LH, Kim JS, Lee SY. Ultrasonics; 2009 Dec 22; 49(8):774-8. PubMed ID: 19635626 [Abstract] [Full Text] [Related]
9. Performance of ultrasound based measurement of 3D displacement using a curvilinear probe for organ motion tracking. Harris EJ, Miller NR, Bamber JC, Evans PM, Symonds-Tayler JR. Phys Med Biol; 2007 Sep 21; 52(18):5683-703. PubMed ID: 17804889 [Abstract] [Full Text] [Related]
10. High frame rate ultrasonic imaging system based on the angular spectrum principle. Peng H, Lu J, Han X. Ultrasonics; 2006 Dec 22; 44 Suppl 1():e97-9. PubMed ID: 16870222 [Abstract] [Full Text] [Related]
11. Multi-parameter ultrasound transmission tomography of biological media. Opielinski KJ, Gudra T. Ultrasonics; 2006 Dec 22; 44 Suppl 1():e295-302. PubMed ID: 17005227 [Abstract] [Full Text] [Related]
12. Extract echo signal in HFR imaging system. Peng H, Wang J, Han X, Zhang S. Ultrasonics; 2006 Dec 22; 44 Suppl 1():e89-91. PubMed ID: 16857231 [Abstract] [Full Text] [Related]
13. Motion estimation in ultrasound images using time domain cross correlation with prior estimates. Zahiri-Azar R, Salcudean SE. IEEE Trans Biomed Eng; 2006 Oct 22; 53(10):1990-2000. PubMed ID: 17019863 [Abstract] [Full Text] [Related]
14. Noise reduction using spatial-angular compounding for elastography. Techavipoo U, Chen Q, Varghese T, Zagzebski JA, Madsen EL. IEEE Trans Ultrason Ferroelectr Freq Control; 2004 May 22; 51(5):510-20. PubMed ID: 15217229 [Abstract] [Full Text] [Related]
15. Sensorless freehand 3D ultrasound in real tissue: speckle decorrelation without fully developed speckle. Gee AH, James Housden R, Hassenpflug P, Treece GM, Prager RW. Med Image Anal; 2006 Apr 22; 10(2):137-49. PubMed ID: 16143560 [Abstract] [Full Text] [Related]
16. Performance evaluation of methods for two-dimensional displacement and strain estimation using ultrasound radio frequency data. Lopata RG, Nillesen MM, Hansen HH, Gerrits IH, Thijssen JM, de Korte CL. Ultrasound Med Biol; 2009 May 22; 35(5):796-812. PubMed ID: 19282094 [Abstract] [Full Text] [Related]
17. Assessing image quality in effective Poisson's ratio elastography and poroelastography: II. Righetti R, Ophir J, Kumar AT, Krouskop TA. Phys Med Biol; 2007 Mar 07; 52(5):1321-33. PubMed ID: 17301457 [Abstract] [Full Text] [Related]
18. Computer vision elastography: speckle adaptive motion estimation for elastography using ultrasound sequences. Revell J, Mirmehdi M, McNally D. IEEE Trans Med Imaging; 2005 Jun 07; 24(6):755-66. PubMed ID: 15957599 [Abstract] [Full Text] [Related]
19. Ultrasonic strain imaging and reconstructive elastography for biological tissue. Khaled W, Reichling S, Bruhns OT, Ermert H. Ultrasonics; 2006 Dec 22; 44 Suppl 1():e199-202. PubMed ID: 16857230 [Abstract] [Full Text] [Related]
20. High-resolution ultrasonic imaging using fast two-dimensional homomorphic filtering. Jirík R, Taxt T. IEEE Trans Ultrason Ferroelectr Freq Control; 2006 Aug 22; 53(8):1440-8. PubMed ID: 16921896 [Abstract] [Full Text] [Related] Page: [Next] [New Search]