1. Using channel depth to isolate and control flow in a micro free-flow electrophoresis device. Fonslow BR, Barocas VH, Bowser MT. Anal Chem; 2006 Aug 01; 78(15):5369-74. PubMed ID: 16878871 [Abstract] [Full Text] [Related]
2. Free-flow zone electrophoresis and isoelectric focusing using a microfabricated glass device with ion permeable membranes. Kohlheyer D, Besselink GA, Schlautmann S, Schasfoort RB. Lab Chip; 2006 Mar 01; 6(3):374-80. PubMed ID: 16511620 [Abstract] [Full Text] [Related]
4. Microfluidic high-resolution free-flow isoelectric focusing. Kohlheyer D, Eijkel JC, Schlautmann S, van den Berg A, Schasfoort RB. Anal Chem; 2007 Nov 01; 79(21):8190-8. PubMed ID: 17902700 [Abstract] [Full Text] [Related]
5. Optimizing band width and resolution in micro-free flow electrophoresis. Fonslow BR, Bowser MT. Anal Chem; 2006 Dec 15; 78(24):8236-44. PubMed ID: 17165812 [Abstract] [Full Text] [Related]
6. Multichannel microchip electrophoresis device fabricated in polycarbonate with an integrated contact conductivity sensor array. Shadpour H, Hupert ML, Patterson D, Liu C, Galloway M, Stryjewski W, Goettert J, Soper SA. Anal Chem; 2007 Feb 01; 79(3):870-8. PubMed ID: 17263312 [Abstract] [Full Text] [Related]
7. Protein separation using free-flow electrophoresis microchip etched in a single step. Wang P, Zhang L, Shan Y, Cong Y, Liang Y, Han B, Liang Z, Zhang Y. J Sep Sci; 2010 Jul 01; 33(13):2039-44. PubMed ID: 20506429 [Abstract] [Full Text] [Related]
8. Electrostatic induction of the electric field into free-flow electrophoresis devices. Janasek D, Schilling M, Manz A, Franzke J. Lab Chip; 2006 Jun 01; 6(6):710-3. PubMed ID: 16738720 [Abstract] [Full Text] [Related]
9. Electrokinetic-driven microfluidic system in poly(dimethylsiloxane) for mass spectrometry detection integrating sample injection, capillary electrophoresis, and electrospray emitter on-chip. Thorslund S, Lindberg P, Andrén PE, Nikolajeff F, Bergquist J. Electrophoresis; 2005 Dec 01; 26(24):4674-83. PubMed ID: 16273585 [Abstract] [Full Text] [Related]
10. Development of a microfabricated palladium decoupler/electrochemical detector for microchip capillary electrophoresis using a hybrid glass/poly(dimethylsiloxane) device. Lacher NA, Lunte SM, Martin RS. Anal Chem; 2004 May 01; 76(9):2482-91. PubMed ID: 15117187 [Abstract] [Full Text] [Related]
14. A high-performance polycarbonate electrophoresis microchip with integrated three-electrode system for end-channel amperometric detection. Wang Y, Chen H, He Q, Soper SA. Electrophoresis; 2008 May 15; 29(9):1881-8. PubMed ID: 18393335 [Abstract] [Full Text] [Related]
16. Effect of buffer flow on DNA separation in a microfabricated electrophoresis system. Chen Z, Burns MA. Electrophoresis; 2005 Dec 15; 26(24):4718-28. PubMed ID: 16294296 [Abstract] [Full Text] [Related]
17. Electrode array detector for microchip capillary electrophoresis. Holcomb RE, Kraly JR, Henry CS. Analyst; 2009 Mar 15; 134(3):486-92. PubMed ID: 19238284 [Abstract] [Full Text] [Related]