These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
365 related items for PubMed ID: 16920343
1. AutoNR: an automated system that measures ECAP thresholds with the Nucleus Freedom cochlear implant via machine intelligence. Botros A, van Dijk B, Killian M. Artif Intell Med; 2007 May; 40(1):15-28. PubMed ID: 16920343 [Abstract] [Full Text] [Related]
2. Clinical results of AutoNRT, a completely automatic ECAP recording system for cochlear implants. van Dijk B, Botros AM, Battmer RD, Begall K, Dillier N, Hey M, Lai WK, Lenarz T, Laszig R, Morsnowski A, Müller-Deile J, Psarros C, Shallop J, Weber B, Wesarg T, Zarowski A, Offeciers E. Ear Hear; 2007 Aug; 28(4):558-70. PubMed ID: 17609616 [Abstract] [Full Text] [Related]
3. Neural response telemetry reconsidered: I. The relevance of ECAP threshold profiles and scaled profiles to cochlear implant fitting. Botros A, Psarros C. Ear Hear; 2010 Jun; 31(3):367-79. PubMed ID: 20124902 [Abstract] [Full Text] [Related]
4. Clinical use of a system for the automated recording and analysis of electrically evoked compound action potentials (ECAPs) in cochlear implant patients. Gärtner L, Lenarz T, Joseph G, Büchner A. Acta Otolaryngol; 2010 Jun; 130(6):724-32. PubMed ID: 19958247 [Abstract] [Full Text] [Related]
9. [The intraoperative application of neural response telemetry with the nucleus CI24M cochlear implant]. Yang H, Tang J, Cao K, Zhu X, Wang Y, Pan T. Zhonghua Er Bi Yan Hou Ke Za Zhi; 2001 Oct; 36(5):352-6. PubMed ID: 12761943 [Abstract] [Full Text] [Related]
12. Evaluation of a novel, noninvasive, objective test of auditory nerve function in cochlear implant candidates. Gräbel S, Hirschfelder A, Scheiber C, Olze H. Otol Neurotol; 2009 Sep; 30(6):716-24. PubMed ID: 19704358 [Abstract] [Full Text] [Related]
13. Adaptation of the electrically evoked compound action potential (ECAP) recorded from nucleus CI24 cochlear implant users. Clay KM, Brown CJ. Ear Hear; 2007 Dec; 28(6):850-61. PubMed ID: 17982371 [Abstract] [Full Text] [Related]
14. Electrically evoked amplitude modulation following response in cochlear implant candidates: comparison with auditory nerve response telemetry, subjective electrical stimulation, and speech perception. Hirschfelder A, Gräbel S, Olze H. Otol Neurotol; 2012 Aug; 33(6):968-75. PubMed ID: 22772009 [Abstract] [Full Text] [Related]