These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
128 related items for PubMed ID: 1692123
1. Effect of the intertrain pause on the ventricular effective refractory period measured by the extrastimulus technique. Morady F, Kadish AH, Rosenheck S, Schmaltz S, Debuitleir M. Pacing Clin Electrophysiol; 1990 Apr; 13(4):405-9. PubMed ID: 1692123 [Abstract] [Full Text] [Related]
2. Comparison of ventricular refractory periods determined by incremental and decremental scanning of an extrastimulus. Morady F, Kadish AH, Kushner JA, Toivonen LK, Schmaltz S. Pacing Clin Electrophysiol; 1989 Apr; 12(4 Pt 1):546-54. PubMed ID: 2470036 [Abstract] [Full Text] [Related]
6. Is the ventricular effective refractory period different when determined by incremental versus decremental scanning?: the effect of pacing cycle length, d-sotalol, and levcromakalim. Leerssen HM, Vos MA, den Dulk K, van der Zande J, Wellens HJ. Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):2084-9. PubMed ID: 7845822 [Abstract] [Full Text] [Related]
9. Monophasic action potential duration during programmed electrical stimulation. Kanaan N, Jenkins J, Childs K, Ge YZ, Kadish A. Pacing Clin Electrophysiol; 1991 Jun; 14(6):1049-59. PubMed ID: 1715066 [Abstract] [Full Text] [Related]
10. Effect of activation sequence on ventricular refractoriness as determined by extrastimuli. Linker NJ, Dancy M, Malik M, Jones S, Ward DE. Cardiovasc Res; 1990 Aug; 24(8):659-64. PubMed ID: 2224933 [Abstract] [Full Text] [Related]
11. Lack of benefit of very short basic drive train cycle length or repetition of extrastimulus coupling intervals for induction of ventricular tachycardia. Lee CS, Wan SH, Cooper MJ, Ross DL. J Cardiovasc Electrophysiol; 1998 Jun; 9(6):574-81. PubMed ID: 9654221 [Abstract] [Full Text] [Related]
12. Detection of rapid changes in ventricular refractoriness in human studies. Toivonen L, Kettunen E, Simelius K, Parikka H. Pacing Clin Electrophysiol; 2002 Mar; 25(3):300-7. PubMed ID: 11990659 [Abstract] [Full Text] [Related]
13. Use-dependent electrophysiologic effects of DL-sotalol and modulation by isoproterenol in the human ventricle. Naitoh N, Furushima H, Ohira K, Taneda K, Aizawa Y. Jpn Heart J; 1998 Mar; 39(2):153-61. PubMed ID: 9687824 [Abstract] [Full Text] [Related]
14. Cumulative effects of cycle length on ventricular refractoriness in man. Brownstein SL, Blackwell WH, Welch WJ, Bauernfeind RA. Am Heart J; 1990 Feb; 119(2 Pt 1):324-30. PubMed ID: 2301221 [Abstract] [Full Text] [Related]
15. Time dependence of ventricular refractory periods: implications for electrophysiologic protocols. Strobel RE, Fisher JD, Katz G, Kim SG, Mercando AD. J Am Coll Cardiol; 1990 Feb; 15(2):402-11. PubMed ID: 2299083 [Abstract] [Full Text] [Related]
16. Effect of spatial separation of stimulation sites on ventricular refractoriness during programmed electrical stimulation. Stevenson WG, Wiener I, Weiss JN. Am Heart J; 1987 Dec; 114(6):1396-9. PubMed ID: 3687693 [Abstract] [Full Text] [Related]
17. Applicability of the stimulus-T interval for antitachycardia pacing. den Dulk K, Leerssen H, Vos M, Leunissen J, Dassen W, Kersemakers J, Begemann M, Wellens H. Pacing Clin Electrophysiol; 1991 Nov; 14(11 Pt 2):1757-61. PubMed ID: 1721170 [Abstract] [Full Text] [Related]
18. Influence of duration of rapid ventricular pacing on ventricular refractoriness in the presence of propafenone and lidocaine. Stark U, Stark G, Kasper K, Schwarzl I, Decrinis M, Pilger E, Tritthart HA. Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 1):43-50. PubMed ID: 9121970 [Abstract] [Full Text] [Related]
19. Effect of sudden rate acceleration on the human His-Purkinje system: adaptation of refractoriness in a dampened oscillatory pattern. Tchou PJ, Lehmann MH, Dongas J, Mahmud R, Denker ST, Akhtar M. Circulation; 1986 May; 73(5):920-9. PubMed ID: 3698237 [Abstract] [Full Text] [Related]
20. The ventricular excitability-interval relationship in early diastole in humans: the influence of the electrode configuration during bipolar stimulation. Toivonen LK, Kadish AH, Kou WH, Morady F. Pacing Clin Electrophysiol; 1990 Jul; 13(7):875-81. PubMed ID: 1695744 [Abstract] [Full Text] [Related] Page: [Next] [New Search]