These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


594 related items for PubMed ID: 16966866

  • 21. A randomized trial of pulsatile perfusion using an intra-aortic balloon pump versus nonpulsatile perfusion on short-term changes in kidney function during cardiopulmonary bypass during myocardial reperfusion.
    Onorati F, Presta P, Fuiano G, Mastroroberto P, Comi N, Pezzo F, Tozzo C, Renzulli A.
    Am J Kidney Dis; 2007 Aug; 50(2):229-38. PubMed ID: 17660024
    [Abstract] [Full Text] [Related]

  • 22. The impact of pump settings on the quality of pulsatility.
    Rider AR, Ressler NM, Karkhanis TR, Kunselman AR, Wang S, Undar A.
    ASAIO J; 2009 Aug; 55(1):100-5. PubMed ID: 19092653
    [Abstract] [Full Text] [Related]

  • 23. Ventricular assist device outflow-graft site: effect on myocardial blood flow.
    Tuzun E, Narin C, Gregoric ID, Cohn WE, Frazier OH.
    J Surg Res; 2011 Nov; 171(1):71-5. PubMed ID: 20605602
    [Abstract] [Full Text] [Related]

  • 24. In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump.
    Herreros J, Ubilla M, Berjano EJ, Vila-Nuñez JE, Páramo JA, Sola J, Mercé S.
    Artif Organs; 2010 Feb; 34(2):140-6. PubMed ID: 20085571
    [Abstract] [Full Text] [Related]

  • 25. In vitro hemodynamic evaluation of a novel pulsatile extracorporeal life support system: impact of perfusion modes and circuit components on energy loss.
    Wang S, Kunselman AR, Clark JB, Ündar A.
    Artif Organs; 2015 Jan; 39(1):59-66. PubMed ID: 25586773
    [Abstract] [Full Text] [Related]

  • 26. The possibility of a veno-arterial bypass system using the Abiomed BVS 5000.
    Sezai A, Shiono M, Nakata K, Hata M, Taoka M, Negishi N, Sezai Y.
    Artif Organs; 2006 Jan; 30(1):74-7. PubMed ID: 16409401
    [Abstract] [Full Text] [Related]

  • 27. Effects of intra-aortic balloon pump versus centrifugal pump on myocardial energetics and systemic circulation in a porcine model of rapidly worsening acute heart failure.
    Ntalianis AS, Drakos SG, Charitos C, Dolou P, Pierrakos CN, Terrovitis JV, Papaioannou T, Charitos E, Nanas JN.
    ASAIO J; 2008 Jan; 54(6):600-5. PubMed ID: 19033773
    [Abstract] [Full Text] [Related]

  • 28. The effects of pulsatile versus non-pulsatile extracorporeal circulation on the pattern of coronary artery blood flow during cardiac arrest.
    Son HS, Sun K, Fang YH, Park SY, Hwang CM, Park SM, Lee SH, Kim KT, Lee IS.
    Int J Artif Organs; 2005 Jun; 28(6):609-16. PubMed ID: 16015571
    [Abstract] [Full Text] [Related]

  • 29. Optimizing the circuit of a pulsatile extracorporeal life support system in terms of energy equivalent pressure and surplus hemodynamic energy.
    Lim CH, Yang S, Choi JW, Sun K.
    Artif Organs; 2009 Nov; 33(11):1015-20. PubMed ID: 19849687
    [Abstract] [Full Text] [Related]

  • 30. Pulsatile perfusion with intra-aortic balloon pumping ameliorates whole body response to cardiopulmonary bypass in the elderly.
    Onorati F, Santarpino G, Presta P, Caroleo S, Abdalla K, Santangelo E, Gulletta E, Fuiano G, Costanzo FS, Renzulli A.
    Crit Care Med; 2009 Mar; 37(3):902-11. PubMed ID: 19237895
    [Abstract] [Full Text] [Related]

  • 31. Clinical evaluation of pulsatile flow mode of Terumo Capiox centrifugal pump.
    Nishida H, Uesugi H, Nishinaka T, Uwabe K, Aomi S, Endo M, Koyanagi H, Oshiyama H, Nogawa A, Akutsu T.
    Artif Organs; 1997 Jul; 21(7):816-21. PubMed ID: 9212965
    [Abstract] [Full Text] [Related]

  • 32. In vitro evaluation of the performance of Korean pulsatile ECLS (T-PLS) using precise quantification of pressure-flow waveforms.
    Lee JJ, Lim CH, Son HS, Kim HK, Hwang CM, Park YD, Moon KC, Kwak YT, Sun K.
    ASAIO J; 2005 Jul; 51(5):604-8. PubMed ID: 16322725
    [Abstract] [Full Text] [Related]

  • 33. The impact of intraaortic balloon counterpulsation on bypass graft flow in patients with peripheral ECMO.
    Madershahian N, Liakopoulos OJ, Wippermann J, Salehi-Gilani S, Wittwer T, Choi YH, Naraghi H, Wahlers T.
    J Card Surg; 2009 Jul; 24(3):265-8. PubMed ID: 19438779
    [Abstract] [Full Text] [Related]

  • 34. [Clinical application of intro-aortic balloon pump and centrifugal pump in low cardiac output syndrome after coronary artery bypass grafting].
    Li XH, Xiao F, Cui HJ, Li Y, Li FJ, Song NQ, Du YL, Zhang ML.
    Zhonghua Wai Ke Za Zhi; 2004 Aug 22; 42(16):965-7. PubMed ID: 15363230
    [Abstract] [Full Text] [Related]

  • 35. Intra-aortic balloon pump-induced pulsatile flow reduces coagulative and fibrinolytic response to cardiopulmonary bypass.
    Onorati F, Esposito A, Comi MC, Impiombato B, Cristodoro L, Mastroroberto P, Renzulli A.
    Artif Organs; 2008 Jun 22; 32(6):433-41. PubMed ID: 18422802
    [Abstract] [Full Text] [Related]

  • 36. Mechanical assistance by intra-aortic balloon pump counterpulsation during reperfusion increases coronary blood flow and mitigates the no-reflow phenomenon: an experimental study.
    Pierrakos CN, Bonios MJ, Drakos SG, Charitos EI, Tsolakis EJ, Ntalianis A, Nanas SN, Charitos CE, Nanas JN, Terrovitis JV.
    Artif Organs; 2011 Sep 22; 35(9):867-74. PubMed ID: 21726241
    [Abstract] [Full Text] [Related]

  • 37. Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model.
    Wang S, Kunselman AR, Myers JL, Undar A.
    ASAIO J; 2008 Sep 22; 54(5):538-41. PubMed ID: 18812749
    [Abstract] [Full Text] [Related]

  • 38. [The effect of intra-aortic balloon pumping on the graft of coronary artery bypass grafting].
    Nakada K, Akiyama K, Koga M, Hasegawa M, Hattori T, Funabashi M, Negishi N.
    Kyobu Geka; 2003 May 22; 56(5):371-5. PubMed ID: 12739358
    [Abstract] [Full Text] [Related]

  • 39. Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis.
    Lu PJ, Yang CF, Wu MY, Hung CH, Chan MY, Hsu TC.
    J Thorac Cardiovasc Surg; 2011 Nov 22; 142(5):1205-13. PubMed ID: 21477820
    [Abstract] [Full Text] [Related]

  • 40. Effects of intra-aortic balloon pumping on graft flow in coronary surgery: an intraoperative transit-time flowmetric study.
    Takami Y, Masumoto H.
    Ann Thorac Surg; 2008 Sep 22; 86(3):823-7. PubMed ID: 18721567
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 30.