  • 1. Underestimation of pacing threshold as determined by an automatic ventricular threshold testing algorithm.
    Sauer WH, Cooper JM, Lai RW, Verdino RJ.
    Pacing Clin Electrophysiol; 2006 Sep; 29(9):1028-30. PubMed ID: 16981932
    [Abstract] [Full Text] [Related]

  • 2. RE: Sauer et al, PACE 2006; 29: 1028-1030.
    Levine PA.
    Pacing Clin Electrophysiol; 2007 Feb; 30(2):290; author reply 290-1. PubMed ID: 17338733
    [No Abstract] [Full Text] [Related]

  • 3. Performance of a ventricular automatic-capture algorithm in a wide clinical setting.
    Pecora D, Morandi F, Liccardo M, Pepi P, Orazi S, Caico SI, Scaccia A, Bizeau O, Citerne O, Raciti G, Del Giudice G.
    Pacing Clin Electrophysiol; 2008 Dec; 31(12):1546-53. PubMed ID: 19067806
    [Abstract] [Full Text] [Related]

  • 4. Performance evaluation of a right atrial automatic capture verification algorithm using two different sensing configurations.
    Sperzel J, Goetze S, Kennergren C, Biffi M, Brooke MJ, Vireca E, Saha S, Schubert B, Butter C.
    Pacing Clin Electrophysiol; 2009 May; 32(5):579-87. PubMed ID: 19422578
    [Abstract] [Full Text] [Related]

  • 5. A randomized trial of the effect of automated ventricular capture on device longevity and threshold measurement in pacemaker patients.
    Koplan BA, Gilligan DM, Nguyen LS, Lau TK, Thackeray LM, Berg KC, ULTRA Study Investigators.
    Pacing Clin Electrophysiol; 2008 Nov; 31(11):1467-74. PubMed ID: 18950305
    [Abstract] [Full Text] [Related]

  • 6. Native QRS complex duration predicts paced QRS width in patients with normal left ventricular function and right ventricular pacing for atrioventricular block.
    Pap R, Fürge P, Bencsik G, Makai A, Sághy L, Forster T.
    J Electrocardiol; 2007 Oct; 40(4):360-4. PubMed ID: 17254598
    [Abstract] [Full Text] [Related]

  • 7. Automatic management of left ventricular stimulation: hints for technologic improvement.
    Biffi M, Bertini M, Saporito D, Ziacchi M, Stabellini S, Valsecchi S, Ricci V, Boriani G.
    Pacing Clin Electrophysiol; 2009 Mar; 32(3):346-53. PubMed ID: 19272065
    [Abstract] [Full Text] [Related]

  • 8. Reduction of RV pacing by continuous optimization of the AV interval.
    Milasinovic G, Sperzel J, Smith TW, Mead H, Brandt J, Haisty WK, Bailey JR, Roelke M, Simonson J, Gerritse B, Englund J, Compton SJ, Worldwide EnPulse Investigators.
    Pacing Clin Electrophysiol; 2006 Apr; 29(4):406-12. PubMed ID: 16650270
    [Abstract] [Full Text] [Related]

  • 9. Modern pacemakers: hope or hype?
    DAS MK, Dandamudi G, Steiner HA.
    Pacing Clin Electrophysiol; 2009 Sep; 32(9):1207-21. PubMed ID: 19719501
    [Abstract] [Full Text] [Related]

  • 10. Acute performance evaluation of a new ventricular automatic capture algorithm.
    Sperzel J, Nowak B, Himmrich E, Zhang G, König A, Willems R, Reister C, Sathaye A, Fröhlig G.
    Europace; 2006 Jan; 8(1):65-9. PubMed ID: 16627412
    [Abstract] [Full Text] [Related]

  • 11. Electrical performance and automatic capture characteristics of a 3.5-mm(2) passive fixation lead during 1-year follow-up.
    Lotze U, Fischer S, Höfs T, Liebetrau J, Fettin W, Scheiner J, Lang A, German IsoFlex Lead Registry Investigators.
    Pacing Clin Electrophysiol; 2009 Aug; 32(8):1050-5. PubMed ID: 19659625
    [Abstract] [Full Text] [Related]

  • 12. Automatic left ventricular pacing management: not only a technical step up.
    Ricci RP.
    Europace; 2009 Jul; 11(7):848-9. PubMed ID: 19546187
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Can Autocapture™ Function of Permanent Pacemakers Initiate Ventricular Tachyarrhythmias?
    Akdemir B, Vakil K, Benditt D, Adabag S.
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):92-4. PubMed ID: 26227566