These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. A compact permanent magnet array with a remote homogeneous field. Marble AE, Mastikhin IV, Colpitts BG, Balcom BJ. J Magn Reson; 2007 May; 186(1):100-4. PubMed ID: 17317247 [Abstract] [Full Text] [Related]
3. Rapid polarizing field cycling in magnetic resonance imaging. Matter NI, Scott GC, Grafendorfer T, Macovski A, Conolly SM. IEEE Trans Med Imaging; 2006 Jan; 25(1):84-93. PubMed ID: 16398417 [Abstract] [Full Text] [Related]
4. Analysing radio-frequency coil arrays in high-field magnetic resonance imaging by the combined field integral equation method. Wang S, Duyn JH. Phys Med Biol; 2006 Jun 21; 51(12):3211-29. PubMed ID: 16757872 [Abstract] [Full Text] [Related]
5. A unilateral NMR magnet for sub-structure analysis in the built environment: the Surface GARField. McDonald PJ, Aptaker PS, Mitchell J, Mulheron M. J Magn Reson; 2007 Mar 21; 185(1):1-11. PubMed ID: 17123850 [Abstract] [Full Text] [Related]
9. Electromagnetic analysis of the slotted-tube resonator with a circular cross section for MRI applications. Benabdallah N, Benahmed N, Benyoucef B, Bouhmidi R, Khelif M. Phys Med Biol; 2007 Aug 21; 52(16):4943-52. PubMed ID: 17671345 [Abstract] [Full Text] [Related]
13. Method for nonlinear characterization of radio frequency coils made of high temperature superconducting material in view of magnetic resonance imaging applications. Girard O, Ginefri JC, Poirier-Quinot M, Darrasse L. Rev Sci Instrum; 2007 Dec 21; 78(12):124703. PubMed ID: 18163742 [Abstract] [Full Text] [Related]
14. Design and performance issues of RF coils utilized in ultra high field MRI: experimental and numerical evaluations. Ibrahim TS, Kangarlu A, Chakeress DW. IEEE Trans Biomed Eng; 2005 Jul 21; 52(7):1278-84. PubMed ID: 16041991 [Abstract] [Full Text] [Related]
16. Design and performance of a planar-array MIT system with normal sensor alignment. Igney CH, Watson S, Williams RJ, Griffiths H, Dössel O. Physiol Meas; 2005 Apr 21; 26(2):S263-78. PubMed ID: 15798239 [Abstract] [Full Text] [Related]
17. An improved equivalent magnetization current method applied to the design of local breast gradient coils. Lopez HS, Poole M, Crozier S. J Magn Reson; 2009 Jul 21; 199(1):48-55. PubMed ID: 19375368 [Abstract] [Full Text] [Related]
18. A new decoupling method for quadrature coils in magnetic resonance imaging. Hui HT, Li BK, Crozier S. IEEE Trans Biomed Eng; 2006 Oct 21; 53(10):2114-6. PubMed ID: 17019876 [Abstract] [Full Text] [Related]