3. Markers of past syphilis in HIV infection comparing Captia Syphilis G anti-treponemal IgG enzyme immunoassay with other treponemal antigen tests. Young H, Moyes A, Ross JD. Int J STD AIDS; 1995; 6(2):101-4. PubMed ID: 7779920 [Abstract] [Full Text] [Related]
4. Analytical evaluation of nine serological assays for diagnosis of syphilis. Malm K, Andersson S, Fredlund H, Norrgren H, Biague A, Månsson F, Ballard R, Unemo M. J Eur Acad Dermatol Venereol; 2015 Dec; 29(12):2369-76. PubMed ID: 26370737 [Abstract] [Full Text] [Related]
6. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test. Ortiz DA, Loeffelholz MJ. J Clin Microbiol; 2017 Nov; 55(11):3236-3241. PubMed ID: 28878003 [Abstract] [Full Text] [Related]
7. Use of Oral Fluid With a Rapid Treponemal Test for Syphilis Evaluation. Bristow CC, Shannon C, Herbst de Cortina S, Klausner JD. Sex Transm Dis; 2018 Sep; 45(9):e65-e67. PubMed ID: 29596225 [Abstract] [Full Text] [Related]
8. Evaluation of a colloidal gold immunochromatography assay in the detection of Treponema pallidum specific IgM antibody in syphilis serofast reaction patients: a serologic marker for the relapse and infection of syphilis. Lin LR, Tong ML, Fu ZG, Dan B, Zheng WH, Zhang CG, Yang TC, Zhang ZY. Diagn Microbiol Infect Dis; 2011 May; 70(1):10-6. PubMed ID: 21388769 [Abstract] [Full Text] [Related]
10. Screening for treponemal infection by a new enzyme immunoassay. Young H, Moyes A, McMillan A, Robertson DH. Genitourin Med; 1989 Apr; 65(2):72-8. PubMed ID: 2666302 [Abstract] [Full Text] [Related]
11. Development of a colloidal gold-immunochromatography assay to detect immunoglobulin G antibodies to Treponema pallidum with TPN17 and TPN47. Lin LR, Fu ZG, Dan B, Jing GJ, Tong ML, Chen DT, Yu Y, Zhang CG, Yang TC, Zhang ZY. Diagn Microbiol Infect Dis; 2010 Nov; 68(3):193-200. PubMed ID: 20846810 [Abstract] [Full Text] [Related]
12. Evaluation of the Bio-Rad BioPlex 2200 syphilis multiplex flow immunoassay for the detection of IgM- and IgG-class antitreponemal antibodies. Gomez E, Jespersen DJ, Harring JA, Binnicker MJ. Clin Vaccine Immunol; 2010 Jun; 17(6):966-8. PubMed ID: 20427627 [Abstract] [Full Text] [Related]
13. Performance evaluation of the Elecsys syphilis assay for the detection of total antibodies to Treponema pallidum. Enders M, Hunjet A, Gleich M, Imdahl R, Mühlbacher A, Schennach H, Chaiwong K, Sakuldamrongpanich T, Turhan A, Sertöz R, Wolf E, Mayer W, Tao C, Wang LL, Semprini S, Sambri V. Clin Vaccine Immunol; 2015 Jan; 22(1):17-26. PubMed ID: 25355799 [Abstract] [Full Text] [Related]
14. Comparative evaluation of the INNO-LIA syphilis score and the MarDx Treponema pallidum immunoglobulin G Marblot test assays for the serological diagnosis of syphilis. Lam TK, Lau HY, Lee YP, Fung SM, Leung WL, Kam KM. Int J STD AIDS; 2010 Feb; 21(2):110-3. PubMed ID: 20089996 [Abstract] [Full Text] [Related]
15. Using Treponemal Assay Signal Strength Cutoff Ratios To Predict Syphilis Infection. Bristow CC, Klausner JD. J Clin Microbiol; 2018 Jan; 56(1):. PubMed ID: 29046409 [Abstract] [Full Text] [Related]
16. An evaluation of a novel dual treponemal/nontreponemal point-of-care test for syphilis as a tool to distinguish active from past treated infection. Causer LM, Kaldor JM, Conway DP, Leslie DE, Denham I, Karapanagiotidis T, Ryan C, Wand H, Anderson DA, Robertson PW, McNulty AM, Donovan B, Fairley CK, Guy RJ. Clin Infect Dis; 2015 Jul 15; 61(2):184-91. PubMed ID: 25810288 [Abstract] [Full Text] [Related]
17. Is serological testing a reliable tool in laboratory diagnosis of syphilis? Meta-analysis of eight external quality control surveys performed by the german infection serology proficiency testing program. Müller I, Brade V, Hagedorn HJ, Straube E, Schörner C, Frosch M, Hlobil H, Stanek G, Hunfeld KP. J Clin Microbiol; 2006 Apr 15; 44(4):1335-41. PubMed ID: 16597859 [Abstract] [Full Text] [Related]
18. Preliminary assessment of Treponema pallidum-specific IgM antibody detection and a new rapid point-of-care assay for the diagnosis of syphilis in human immunodeficiency virus-1-infected patients. Rotty J, Anderson D, Garcia M, Diaz J, Van de Waarsenburg S, Howard T, Dennison A, Lewin SR, Elliott JH, Hoy J. Int J STD AIDS; 2010 Nov 15; 21(11):758-64. PubMed ID: 21187358 [Abstract] [Full Text] [Related]
19. Utility of antitreponemal IgM testing in the diagnosis of early and repeat syphilis among HIV-infected and non-infected patients. Pastuszczak M, Kotnis-Gąska A, Jakubowicz B, Martyka I, Bociaga-Jasik M, Wojas-Pelc A. Int J STD AIDS; 2018 Aug 15; 29(9):890-894. PubMed ID: 29629652 [Abstract] [Full Text] [Related]
20. Current trend on syphilis diagnosis: issues and challenges. Morshed MG. Adv Exp Med Biol; 2014 Aug 15; 808():51-64. PubMed ID: 24595610 [Abstract] [Full Text] [Related] Page: [Next] [New Search]