These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
193 related items for PubMed ID: 17073327
1. An improved adaptive power line interference canceller for electrocardiography. Martens SM, Mischi M, Oei SG, Bergmans JW. IEEE Trans Biomed Eng; 2006 Nov; 53(11):2220-31. PubMed ID: 17073327 [Abstract] [Full Text] [Related]
2. [The algorithm based on wavelet for canceling muscle electricity and wide range frequency of power line hum in ECG]. Zhao J, Hua M. Space Med Med Eng (Beijing); 2004 Jun; 17(3):224-8. PubMed ID: 15920849 [Abstract] [Full Text] [Related]
3. Real time implementation of genetic algorithm cancellation of sinusoidal noise in ECG using TMS320C50 DSP processor. Kumaravel N, Viswanathan SM. Biomed Sci Instrum; 1999 Jun; 35():169-74. PubMed ID: 11143342 [Abstract] [Full Text] [Related]
4. Low-cost, high-fidelity, adaptive cancellation of periodic 60 Hz noise. Wesson KD, Ochshorn RM, Land BR. J Neurosci Methods; 2009 Dec 15; 185(1):50-5. PubMed ID: 19765614 [Abstract] [Full Text] [Related]
5. Power-line interference detection and suppression in ECG signal processing. Lin YD, Hu YH. IEEE Trans Biomed Eng; 2008 Jan 15; 55(1):354-7. PubMed ID: 18232382 [Abstract] [Full Text] [Related]
6. [Research of adaptive notch filter based on QRD-LS algorithm for power line interference in ECG]. Wang S, Dong J, Guan X. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Oct 15; 25(5):1044-7. PubMed ID: 19024443 [Abstract] [Full Text] [Related]
7. Event-synchronous cancellation of the heart interference in biomedical signals. Strobach P, Abraham-Fuchs K, Härer W. IEEE Trans Biomed Eng; 1994 Apr 15; 41(4):343-50. PubMed ID: 8063300 [Abstract] [Full Text] [Related]
8. A novel application of the S-transform in removing powerline interference from biomedical signals. Huang CC, Liang SF, Young MS, Shaw FZ. Physiol Meas; 2009 Jan 15; 30(1):13-27. PubMed ID: 19039164 [Abstract] [Full Text] [Related]
9. Integrating the ECG power-line interference removal methods with rule-based system. Kumaravel N, Senthil A, Sridhar KS, Nithiyanandam N. Biomed Sci Instrum; 1995 Jan 15; 31():115-20. PubMed ID: 7654947 [Abstract] [Full Text] [Related]
10. Adaptive digital notch filter design on the unit circle for the removal of powerline noise from biomedical signals. Ferdjallah M, Barr RE. IEEE Trans Biomed Eng; 1994 Jun 15; 41(6):529-36. PubMed ID: 7927372 [Abstract] [Full Text] [Related]
11. A method for reduction of power line interference in the ECG. Mitov IP. Med Eng Phys; 2004 Dec 15; 26(10):879-87. PubMed ID: 15567704 [Abstract] [Full Text] [Related]
12. A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG. Hamilton PS. IEEE Trans Biomed Eng; 1996 Jan 15; 43(1):105-9. PubMed ID: 8567001 [Abstract] [Full Text] [Related]
13. Removing harmonic power line interference from biopotential signals in low cost acquisition systems. Costa MH, Tavares MC. Comput Biol Med; 2009 Jun 15; 39(6):519-26. PubMed ID: 19376509 [Abstract] [Full Text] [Related]
14. [Arithmetic for subtracting power line interference based on estimating sinusoidal parameters]. Hu X, Wei W, Liu C, Han X. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Dec 15; 27(6):1243-6. PubMed ID: 21374972 [Abstract] [Full Text] [Related]
15. A fast, robust algorithm for power line interference cancellation in neural recording. Keshtkaran MR, Yang Z. J Neural Eng; 2014 Apr 15; 11(2):026017. PubMed ID: 24658388 [Abstract] [Full Text] [Related]
16. Elimination of AC interference in electrocardiogram using IIR notch filter with transient suppression. Pei SC, Tseng CC. IEEE Trans Biomed Eng; 1995 Nov 15; 42(11):1128-32. PubMed ID: 7498917 [Abstract] [Full Text] [Related]
17. A biosignal instrumentation system using capacitive coupling for power and signal isolation. Piipponen KV, Sepponen R, Eskelinen P. IEEE Trans Biomed Eng; 2007 Oct 15; 54(10):1822-8. PubMed ID: 17926680 [Abstract] [Full Text] [Related]
18. A Fixed-Lag Kalman Smoother to Filter Power Line Interference in Electrocardiogram Recordings. Warmerdam GJJ, Vullings R, Schmitt L, Van Laar JOEH, Bergmans JWM. IEEE Trans Biomed Eng; 2017 Aug 15; 64(8):1852-1861. PubMed ID: 27845652 [Abstract] [Full Text] [Related]
19. Basic aspects concerning the event-synchronous interference canceller. Ungureanu M, Wolf WM. IEEE Trans Biomed Eng; 2006 Nov 15; 53(11):2240-7. PubMed ID: 17073329 [Abstract] [Full Text] [Related]
20. Filtering electrocardiographic signals using an unbiased and normalized adaptive noise reduction system. Wu Y, Rangayyan RM, Zhou Y, Ng SC. Med Eng Phys; 2009 Jan 15; 31(1):17-26. PubMed ID: 18472295 [Abstract] [Full Text] [Related] Page: [Next] [New Search]