21. Oxygen effects on glucose measurements with a reference analyzer and three handheld meters. Tang Z, Louie RF, Payes M, Chang KC, Kost GJ. Diabetes Technol Ther; 2000; 2(3):349-62. PubMed ID: 11467337 [Abstract] [Full Text] [Related]
22. Performance of strip-based glucose meters and cassette-based blood gas analyzer for monitoring glucose levels in a surgical intensive care setting. Claerhout H, De Prins M, Mesotten D, Van den Berghe G, Mathieu C, Van Eldere J, Vanstapel F. Clin Chem Lab Med; 2016 Jan; 54(1):169-80. PubMed ID: 26136300 [Abstract] [Full Text] [Related]
25. Factors interfering with the accuracy of five blood glucose meters used in Chinese hospitals. Lv H, Zhang GJ, Kang XX, Yuan H, Lv YW, Wang WW, Randall R. J Clin Lab Anal; 2013 Sep; 27(5):354-66. PubMed ID: 24038220 [Abstract] [Full Text] [Related]
26. A glucose meter accuracy and precision comparison: the FreeStyle Flash Versus the Accu-Chek Advantage, Accu-Chek Compact Plus, Ascensia Contour, and the BD Logic. Thomas LE, Kane MP, Bakst G, Busch RS, Hamilton RA, Abelseth JM. Diabetes Technol Ther; 2008 Apr; 10(2):102-10. PubMed ID: 18260773 [Abstract] [Full Text] [Related]
30. Evaluation of two reagent strips and three reflectance meters for rapid determination of blood glucose concentrations. Joseph RJ, Allyson K, Graves TK, Rondeau MJ, Peterson ME. J Vet Intern Med; 1987 Apr; 1(4):170-4. PubMed ID: 3506102 [Abstract] [Full Text] [Related]
31. Point-of-care glucose analysis in neonates using modified quinoprotein glucose dehydrogenase. Dietzen DJ, Wilhite TR, Rasmussen M, Sheffield M. Diabetes Technol Ther; 2013 Nov; 15(11):923-8. PubMed ID: 23931714 [Abstract] [Full Text] [Related]
32. Accuracy and precision evaluation of seven self-monitoring blood glucose systems. Kuo CY, Hsu CT, Ho CS, Su TE, Wu MH, Wang CJ. Diabetes Technol Ther; 2011 May; 13(5):596-600. PubMed ID: 21406013 [Abstract] [Full Text] [Related]
33. Accuracy of AccuChek glucose measurement in intensive care patients. Meynaar IA, van Spreuwel M, Tangkau PL, Dawson L, Sleeswijk Visser S, Rijks L, Vlieland TV. Crit Care Med; 2009 Oct; 37(10):2691-6. PubMed ID: 19885987 [Abstract] [Full Text] [Related]
34. Comparison of several point-of-care testing (POCT) glucometers with an established laboratory procedure for the diagnosis of type 2 diabetes using the discordance rate. A new statistical approach. Püntmann I, Wosniok W, Haeckel R. Clin Chem Lab Med; 2003 Jun; 41(6):809-20. PubMed ID: 12880146 [Abstract] [Full Text] [Related]
35. Large-scale performance evaluation of Accu-Chek inform II point-of-care glucose meters. Jeong TD, Cho EJ, Ko DH, Lee W, Chun S, Hong KS, Min WK. Scand J Clin Lab Invest; 2016 Dec; 76(8):657-663. PubMed ID: 27739331 [Abstract] [Full Text] [Related]
36. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters. Pfützner A, Schipper C, Ramljak S, Flacke F, Sieber J, Forst T, Musholt PB. J Diabetes Sci Technol; 2013 Nov 01; 7(6):1522-9. PubMed ID: 24351178 [Abstract] [Full Text] [Related]