These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


110 related items for PubMed ID: 17110765

  • 1. Design of a computer-controlled multileaf collimator for advanced electron radiotherapy.
    Gauer T, Albers D, Cremers F, Harmansa R, Pellegrini R, Schmidt R.
    Phys Med Biol; 2006 Dec 07; 51(23):5987-6003. PubMed ID: 17110765
    [Abstract] [Full Text] [Related]

  • 2. Characterization of an add-on multileaf collimator for electron beam therapy.
    Gauer T, Sokoll J, Cremers F, Harmansa R, Luzzara M, Schmidt R.
    Phys Med Biol; 2008 Feb 21; 53(4):1071-85. PubMed ID: 18263959
    [Abstract] [Full Text] [Related]

  • 3. Dosimetric verification of a Monte Carlo electron beam model for an add-on eMLC.
    Vatanen T, Traneus E, Lahtinen T.
    Phys Med Biol; 2008 Jan 21; 53(2):391-404. PubMed ID: 18184994
    [Abstract] [Full Text] [Related]

  • 4. Characterization of an extendable multi-leaf collimator for clinical electron beams.
    O'Shea TP, Ge Y, Foley MJ, Faddegon BA.
    Phys Med Biol; 2011 Dec 07; 56(23):7621-38. PubMed ID: 22086242
    [Abstract] [Full Text] [Related]

  • 5. Measurement and Monte Carlo simulation for energy- and intensity-modulated electron radiotherapy delivered by a computer-controlled electron multileaf collimator.
    Jin L, Eldib A, Li J, Emam I, Fan J, Wang L, Ma CM.
    J Appl Clin Med Phys; 2014 Jan 06; 15(1):4506. PubMed ID: 24423848
    [Abstract] [Full Text] [Related]

  • 6. Improvement of field matching in segmented-field electron conformal therapy using a variable-SCD applicator.
    Richert JD, Hogstrom KR, Fields RS, Matthews KL, Boyd RA.
    Phys Med Biol; 2007 May 07; 52(9):2459-81. PubMed ID: 17440246
    [Abstract] [Full Text] [Related]

  • 7. The effect of electron collimator leaf shape on the build-up dose in narrow electron MLC fields.
    Vatanen T, Traneus E, Väänänen A, Lahtinen T.
    Phys Med Biol; 2009 Dec 07; 54(23):7211-26. PubMed ID: 19920308
    [Abstract] [Full Text] [Related]

  • 8. Potential of discrete Gaussian edge feathering method for improving abutment dosimetry in eMLC-delivered segmented-field electron conformal therapy.
    Eley JG, Hogstrom KR, Matthews KL, Parker BC, Price MJ.
    Med Phys; 2011 Dec 07; 38(12):6610-22. PubMed ID: 22149843
    [Abstract] [Full Text] [Related]

  • 9. Dosimetry of a prototype retractable eMLC for fixed-beam electron therapy.
    Hogstrom KR, Boyd RA, Antolak JA, Svatos MM, Faddegon BA, Rosenman JG.
    Med Phys; 2004 Mar 07; 31(3):443-62. PubMed ID: 15070241
    [Abstract] [Full Text] [Related]

  • 10. Feasibility of replacing patient specific cutouts with a computer-controlled electron multileaf collimator.
    Eldib A, Jin L, Li J, Ma CM.
    Phys Med Biol; 2013 Aug 21; 58(16):5653-72. PubMed ID: 23892910
    [Abstract] [Full Text] [Related]

  • 11. Characterization of megavoltage electron beams delivered through a photon multi-leaf collimator (pMLC).
    du Plessis FC, Leal A, Stathakis S, Xiong W, Ma CM.
    Phys Med Biol; 2006 Apr 21; 51(8):2113-29. PubMed ID: 16585849
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13. Siemens multileaf collimator characterization and quality assurance approaches for intensity-modulated radiotherapy.
    Bayouth JE.
    Int J Radiat Oncol Biol Phys; 2008 Apr 21; 71(1 Suppl):S93-7. PubMed ID: 18406947
    [Abstract] [Full Text] [Related]

  • 14. Effects on electron beam penumbra using the photon MLC to reduce bremsstrahlung leakage for an add-on electron MLC.
    Olofsson L, Karlsson MG, Karlsson M.
    Phys Med Biol; 2005 Mar 21; 50(6):1191-203. PubMed ID: 15798316
    [Abstract] [Full Text] [Related]

  • 15. Optimizing leaf widths for a multileaf collimator.
    Cui W, Dai J.
    Phys Med Biol; 2009 May 21; 54(10):3051-62. PubMed ID: 19398815
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19. An analytical approach for optimizing the leaf design of a multi-leaf collimator in a linear accelerator.
    Topolnjak R, van der Heide UA.
    Phys Med Biol; 2008 Jun 07; 53(11):3007-21. PubMed ID: 18490812
    [Abstract] [Full Text] [Related]

  • 20. Enhancement of electron-beam surface dose with an electron multi-leaf collimator (eMLC): a feasibility study.
    Vatanen T, Traneus E, Lahtinen T.
    Phys Med Biol; 2009 Apr 21; 54(8):2407-19. PubMed ID: 19336845
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 6.