These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
267 related items for PubMed ID: 17116271
61. [Implantable ECG recorder revealed the diagnosis in a baby with apparent life-threatening events]. Hoorntje TM, Langerak W, Blokland-Loggers HE, Sreeram N. Ned Tijdschr Geneeskd; 1999 Sep 25; 143(39):1966-9. PubMed ID: 10526617 [Abstract] [Full Text] [Related]
62. Utility of event loop recorders for the management of arrhythmias in young ambulatory patients. Martinez T, Sztajzel J. Int J Cardiol; 2004 Dec 25; 97(3):495-8. PubMed ID: 15561338 [Abstract] [Full Text] [Related]
63. Reproducibility of electrocardiographic findings in patients with suspected reflex neurally-mediated syncope. Moya A, Brignole M, Sutton R, Menozzi C, Garcia-Civera R, Wieling W, Andresen D, Benditt DG, Garcia-Sacristán JF, Beiras X, Grovale N, Vardas P, International Study on Syncope of Uncertain Etiology 2 (ISSUE 2) Group. Am J Cardiol; 2008 Dec 01; 102(11):1518-23. PubMed ID: 19026307 [Abstract] [Full Text] [Related]
64. [Clinical significance of intracardiac electrocardiography in the diagnosis of syncope]. Chytil V. Vnitr Lek; 1990 Feb 01; 36(2):113-20. PubMed ID: 2336810 [Abstract] [Full Text] [Related]
65. Implantable loop-recorders in myopathic and non-myopathic patients with left ventricular hypertrabeculation/noncompaction. Stöllberger C, Keller H, Steger C, Finsterer J. Int J Cardiol; 2013 Feb 20; 163(2):146-8. PubMed ID: 21652098 [Abstract] [Full Text] [Related]
66. [Role of implantable loop recorder in the clinical diagnosis of syncope: results of the introduction of an effective diagnostic tool]. Somlói M, Toldy-Schedel E, Nényei Z, Böszörményi R, Tomcsányi J. Orv Hetil; 2015 Apr 20; 156(15):609-13. PubMed ID: 25845320 [Abstract] [Full Text] [Related]
67. Performance of an autonomous telemonitoring system in children and young adults with congenital heart diseases. Zartner P, Handke R, Photiadis J, Brecher AM, Schneider MB. Pacing Clin Electrophysiol; 2008 Oct 20; 31(10):1291-9. PubMed ID: 18811810 [Abstract] [Full Text] [Related]
68. The Real-World Utility of the LINQ Implantable Loop Recorder in Pediatric and Adult Congenital Heart Patients. Bezzerides VJ, Walsh A, Martuscello M, Escudero CA, Gauvreau K, Lam G, Abrams DJ, Triedman JK, Alexander ME, Bevilacqua L, Mah DY. JACC Clin Electrophysiol; 2019 Feb 20; 5(2):245-251. PubMed ID: 30784698 [Abstract] [Full Text] [Related]
70. [Syncope in the elderly]. Geller JC, Reek S, Klein HU. Dtsch Med Wochenschr; 2005 Mar 24; 130(12):717-20. PubMed ID: 15776357 [Abstract] [Full Text] [Related]
71. [The implantable loop recorder]. Graf D, Roussianos MO, Schlaepfer J, Forclaz A, Zerm T, Metzger J, Fromer M, Pruvot E. Rev Med Suisse; 2007 Dec 19; 3(138):2914-8. PubMed ID: 18277768 [Abstract] [Full Text] [Related]
72. [Long-term monitoring of patients with a syncope of obscure etiology with an implantable monitoring device]. Kovác J, Skehan JD. Vnitr Lek; 2000 Jun 19; 46(6):328-31. PubMed ID: 15645837 [Abstract] [Full Text] [Related]
73. Maturation of the sensed electrogram amplitude over time in a new subcutaneous implantable loop recorder. Krahn AD, Klein GJ, Yee R, Norris C. Pacing Clin Electrophysiol; 1997 Jun 19; 20(6):1686-90. PubMed ID: 9227768 [Abstract] [Full Text] [Related]
74. Utility of implantable loop recorder (Reveal Plus) in the diagnosis of unexplained syncope. Lombardi F, Calosso E, Mascioli G, Marangoni E, Donato A, Rossi S, Pala M, Foti F, Lunati M. Europace; 2005 Jan 19; 7(1):19-24. PubMed ID: 15670962 [Abstract] [Full Text] [Related]
75. Holter monitoring for syncope: diagnostic yield in different patient groups and impact on device implantation. Kühne M, Schaer B, Moulay N, Sticherling C, Osswald S. QJM; 2007 Dec 19; 100(12):771-7. PubMed ID: 18089543 [Abstract] [Full Text] [Related]
77. Detection of arrhythmias in adult congenital heart disease patients with LINQTM implantable loop recorder. Dodeja AK, Thomas C, Daniels CJ, Kertesz N, Kamp A. Congenit Heart Dis; 2019 Sep 19; 14(5):745-751. PubMed ID: 31313513 [Abstract] [Full Text] [Related]
78. The role of the implantable loop recorder in the investigation of recurrent syncope. Sideris SK, Mousiama TA, Stougiannos PN, Skiadas IP, Laiou FP, Sotiropoulos IK, Gatzoulis KA, Stefanadis C, Kallikazaros IE. Hellenic J Cardiol; 2009 Sep 19; 50(2):155-9. PubMed ID: 19329420 [Abstract] [Full Text] [Related]
79. Diagnostic management of patients with palpitations of unknown origin. Giada F, Raviele A. Ital Heart J; 2004 Aug 19; 5(8):581-6. PubMed ID: 15554028 [Abstract] [Full Text] [Related]
80. Feasibility of the inframammary location for insertable loop recorders in young women and girls. Kannankeril PJ, Bibeau DA, Fish FA. Pacing Clin Electrophysiol; 2004 Apr 19; 27(4):492-4. PubMed ID: 15078403 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]