176 related items for PubMed ID: 17132442
1. Attenuated total internal reflection infrared microspectroscopic imaging using a large-radius germanium internal reflection element and a linear array detector. Patterson BM, Havrilla GJ. Appl Spectrosc; 2006 Nov; 60(11):1256-66. PubMed ID: 17132442 [Abstract] [Full Text] [Related]
3. Approximating the detection limit of an infrared spectroscopic imaging microscope operating in an attenuated total reflection (ATR) modality: theoretical and empirical results for an instrument using a linear array detector and a 1.5 millimeter germanium hemisphere internal reflection element. Lanzarotta A. Appl Spectrosc; 2015 Nov; 69(2):205-14. PubMed ID: 25588210 [Abstract] [Full Text] [Related]
12. Quantitative determination of pharmaceutical drug formulations by near-infrared spectroscopic imaging. Kolomiets O, Hoffmann U, Geladi P, Siesler HW. Appl Spectrosc; 2008 Nov 05; 62(11):1200-8. PubMed ID: 19007460 [Abstract] [Full Text] [Related]
13. Fourier transform infrared imaging of human hair with a high spatial resolution without the use of a synchrotron. Chan KL, Kazarian SG, Mavraki A, Williams DR. Appl Spectrosc; 2005 Feb 05; 59(2):149-55. PubMed ID: 15720754 [Abstract] [Full Text] [Related]
14. Detection Limits for Blood on Fabrics Using Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy and Derivative Processing. Lu Z, DeJong SA, Cassidy BM, Belliveau RG, Myrick ML, Morgan SL. Appl Spectrosc; 2017 May 05; 71(5):839-846. PubMed ID: 27354403 [Abstract] [Full Text] [Related]
15. The Advantages of an Attenuated Total Internal Reflection Infrared Microspectroscopic Imaging Technique for the Analysis of Polymer Laminates. Ling C, Sommer AJ. Microsc Microanal; 2015 Jun 05; 21(3):626-36. PubMed ID: 25980473 [Abstract] [Full Text] [Related]
16. FT-IR microspectroscopy for microbiological studies. Orsini F, Ami D, Villa AM, Sala G, Bellotti MG, Doglia SM. J Microbiol Methods; 2000 Sep 05; 42(1):17-27. PubMed ID: 11000427 [Abstract] [Full Text] [Related]
19. Historical perspective and modern applications of Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy (ATR-FTIR). Blum MM, John H. Drug Test Anal; 2012 Sep 05; 4(3-4):298-302. PubMed ID: 22113892 [Abstract] [Full Text] [Related]