These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. A SiC microdevice for the minimally invasive monitoring of ischemia in living tissues. Gómez R, Ivorra A, Villa R, Godignon P, Millán J, Erill I, Solà A, Hotter G, Palacios L. Biomed Microdevices; 2006 Mar; 8(1):43-9. PubMed ID: 16491330 [Abstract] [Full Text] [Related]
4. Detection of emboli in vessels using electrical impedance measurements--phantom and electrodes. Nebuya S, Noshiro M, Brown BH, Smallwood RH, Milnes P. Physiol Meas; 2005 Apr; 26(2):S111-8. PubMed ID: 15798224 [Abstract] [Full Text] [Related]
5. Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes. Gandhi SV, Walker DC, Brown BH, Anumba DO. Biomed Eng Online; 2006 Nov 24; 5():62. PubMed ID: 17125510 [Abstract] [Full Text] [Related]
9. A portable bio-impedance system for monitoring lung resistivity. Zlochiver S, Arad M, Radai MM, Barak-Shinar D, Krief H, Engelman T, Ben-Yehuda R, Adunsky A, Abboud S. Med Eng Phys; 2007 Jan 15; 29(1):93-100. PubMed ID: 16546432 [Abstract] [Full Text] [Related]
10. [Diagnosis of rejection after kidney transplantation by impedance spectroscopy with an implantable measuring system]. Gerhäusser A, Reichel T, Neukomm PA, Bolz A, Hugel J, Schaldach M. Biomed Tech (Berl); 1997 Jan 15; 42 Suppl():160-1. PubMed ID: 9517095 [No Abstract] [Full Text] [Related]
11. Hemodynamic monitoring during syncope: utility and limitations. Hamdan MH. J Cardiovasc Electrophysiol; 2009 Jan 15; 20(1):82-4. PubMed ID: 18803566 [No Abstract] [Full Text] [Related]
12. Monitoring lung edema using the pacemaker pulse and skin electrodes. Belalcazar A, Patterson R. Physiol Meas; 2005 Apr 15; 26(2):S153-63. PubMed ID: 15798228 [Abstract] [Full Text] [Related]
13. Clinical and anti-HLA antibody profile of nine renal transplant recipients with failed grafts: donor-specific and non-donor-specific antibody development. Rebellato LM, Ozawa M, Verbanac KM, Catrou P, Haisch CE, Terasaki PI. Clin Transpl; 2006 Apr 15; ():241-53. PubMed ID: 18365382 [Abstract] [Full Text] [Related]
14. Limits of clinical signs and non-invasive techniques in detecting severe acute rejection. Bertoni E, Di Maria L, Piperno R, Zanazzi M, Rosati A, Moscarelli L, Salvadori M. J Nephrol; 1999 Apr 15; 12(2):100-3. PubMed ID: 10378666 [Abstract] [Full Text] [Related]
15. Diagnosing acute liver graft rejection: experimental application of an implantable telemetric impedance device in native and transplanted porcine livers. Harms J, Schneider A, Baumgartner M, Henke J, Busch R. Biosens Bioelectron; 2001 May 15; 16(3):169-77. PubMed ID: 11339995 [Abstract] [Full Text] [Related]
16. Application of implantable wireless biomicrosystem for monitoring nerve impedance of rat after sciatic nerve injury. Li YT, Peng CW, Chen LT, Lin WS, Chu CH, Chen JJ. IEEE Trans Neural Syst Rehabil Eng; 2013 Jan 15; 21(1):121-8. PubMed ID: 23060343 [Abstract] [Full Text] [Related]
17. A comparison of two- and four-electrode techniques to characterize blood impedance for the frequency range of 100 Hz to 100 MHz. Chang ZY, Pop GM, Meijer GM. IEEE Trans Biomed Eng; 2008 Mar 15; 55(3):1247-9. PubMed ID: 18334424 [Abstract] [Full Text] [Related]
18. A broadband high-frequency electrical impedance tomography system for breast imaging. Halter RJ, Hartov A, Paulsen KD. IEEE Trans Biomed Eng; 2008 Feb 15; 55(2 Pt 1):650-9. PubMed ID: 18270001 [Abstract] [Full Text] [Related]
19. SU-8 microprobe with microelectrodes for monitoring electrical impedance in living tissues. Tijero M, Gabriel G, Caro J, Altuna A, Hernández R, Villa R, Berganzo J, Blanco FJ, Salido R, Fernández LJ. Biosens Bioelectron; 2009 Apr 15; 24(8):2410-6. PubMed ID: 19167206 [Abstract] [Full Text] [Related]