These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Considerably reduced centrifugation time without increased hemolysis: evaluation of the new BD Vacutainer SSTTMII Advance. Mensel B, Wenzel U, Roser M, Lüdemann J, Nauck M. Clin Chem; 2007 Apr; 53(4):794-5. PubMed ID: 17405947 [No Abstract] [Full Text] [Related]
6. The Usage of Separating Gel Vacuum Tube with Different IgG Concentration. Wang ZE, Song XF, Zou JW, Duan WB, Wang Y, Zhang BC, Wu H. Ann Clin Lab Sci; 2015 Apr; 45(4):438-40. PubMed ID: 26275696 [Abstract] [Full Text] [Related]
7. Evaluation of BD Vacutainer SST™ II plus tubes for special proteins testing. Li Z, Yan C, Yan R, Zheng X, Feng Z. J Clin Lab Anal; 2011 Apr; 25(3):203-6. PubMed ID: 21567469 [Abstract] [Full Text] [Related]
8. [Comparison of two new plastic tubes (Sekisui INSEPACK and Green Cross Green Vac-Tube) with BD Vacutainer tubes for 49 analytes]. Oh SH, Ki CS. Korean J Lab Med; 2007 Feb; 27(1):69-75. PubMed ID: 18094554 [Abstract] [Full Text] [Related]
9. Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study. Kocijancic M, Cargonja J, Delic-Knezevic A. Biochem Med (Zagreb); 2014 Feb; 24(3):368-75. PubMed ID: 25351355 [Abstract] [Full Text] [Related]
11. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube. Arslan FD, Karakoyun I, Basok BI, Aksit MZ, Baysoy A, Ozturk YK, Guclu YA, Duman C. Biochem Med (Zagreb); 2017 Oct 15; 27(3):030706. PubMed ID: 28900369 [Abstract] [Full Text] [Related]
12. Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations. Dasgupta A, Dean R, Saldana S, Kinnaman G, McLawhon RW. Am J Clin Pathol; 1994 Apr 15; 101(4):456-61. PubMed ID: 8160636 [Abstract] [Full Text] [Related]
13. Serum bicarbonate declines with sample size in vacutainer tubes. Herr RD, Swanson T. Am J Clin Pathol; 1992 Feb 15; 97(2):213-6. PubMed ID: 1546690 [Abstract] [Full Text] [Related]
14. Comparison of Improvacuter™ tubes with BD Vacutainer™ tubes for various hormones in the aspects of stability and influence of gel separators. Zungun C, Yılmaz FM, Boru EG, Topcuoglu C. Clin Chem Lab Med; 2015 Feb 15; 53(2):231-8. PubMed ID: 25153600 [Abstract] [Full Text] [Related]
15. Abnormal gel flotation in a patient with apperant pneumonia diagnosis: a case report. Gerin F, Ramazan DC, Baykan O, Sirikci O, Haklar G. Biochem Med (Zagreb); 2014 Feb 15; 24(1):180-2. PubMed ID: 24627728 [Abstract] [Full Text] [Related]
16. Quality of plasma samples and BD Vacutainer Barricor tubes: Effects of centrifugation. Padoan A, Zaninotto M, Piva E, Sciacovelli L, Aita A, Tasinato A, Plebani M. Clin Chim Acta; 2018 Aug 15; 483():271-274. PubMed ID: 29753681 [Abstract] [Full Text] [Related]
17. Evaluation of BD Vacutainer SST™ II Plus tubes for common tumor marker tests by Roche Diagnostics Modular E 170 analyzer. Li Z, Feng Z, Yan C, Yan R. J Clin Lab Anal; 2010 Aug 15; 24(6):418-21. PubMed ID: 21089174 [Abstract] [Full Text] [Related]
18. Use of gel-based separator tubes to stabilise phosphate in mailed blood samples. Herrington W, Clark S, Staplin N, Kumar A, Illingworth N, Sutherland S, Baigent C, Landray M, Haynes R, Hill M. Clin Chim Acta; 2015 Jan 15; 439():112-4. PubMed ID: 25280640 [No Abstract] [Full Text] [Related]
19. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes. Cadamuro J, Mrazek C, Leichtle AB, Kipman U, Felder TK, Wiedemann H, Oberkofler H, Fiedler GM, Haschke-Becher E. Biochem Med (Zagreb); 2018 Feb 15; 28(1):010704. PubMed ID: 29187797 [Abstract] [Full Text] [Related]
20. Unusual interference from primary collection tube in a high-performance liquid chromatography assay of amiodarone. Murthy VV. J Clin Lab Anal; 1997 Feb 15; 11(4):232-4. PubMed ID: 9219066 [Abstract] [Full Text] [Related] Page: [Next] [New Search]