These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
391 related items for PubMed ID: 17363925
1. Intraocular lens power calculation in short eyes. Gavin EA, Hammond CJ. Eye (Lond); 2008 Jul; 22(7):935-8. PubMed ID: 17363925 [Abstract] [Full Text] [Related]
3. [Accuracy of the SRK II, SRK/T, Holladay and Hoffer Q IOL power calculation formulas in hyperopic patients after phacoemulsification]. Szaflik J, Kamińska A, Gajda S, Jedruch A. Klin Oczna; 2005 Jul; 107(10-12):615-9. PubMed ID: 16619803 [Abstract] [Full Text] [Related]
4. Intraocular lens power calculation and optimized constants for highly myopic eyes. Petermeier K, Gekeler F, Messias A, Spitzer MS, Haigis W, Szurman P. J Cataract Refract Surg; 2009 Sep; 35(9):1575-81. PubMed ID: 19683155 [Abstract] [Full Text] [Related]
5. Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2, and SRK/T formulas. Narváez J, Zimmerman G, Stulting RD, Chang DH. J Cataract Refract Surg; 2006 Dec; 32(12):2050-3. PubMed ID: 17137982 [Abstract] [Full Text] [Related]
9. Factors affecting the predictability of SRK II in patients with normal axial length undergoing phacoemulsification surgery. Lim LH, Lee SY, Ang CL. Singapore Med J; 2009 Feb; 50(2):120-5. PubMed ID: 19296025 [Abstract] [Full Text] [Related]
10. Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK. Wang L, Booth MA, Koch DD. Ophthalmology; 2004 Oct; 111(10):1825-31. PubMed ID: 15465542 [Abstract] [Full Text] [Related]
11. Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyes. Savini G, Barboni P, Carbonelli M, Hoffer KJ. J Cataract Refract Surg; 2012 May; 38(5):787-92. PubMed ID: 22386277 [Abstract] [Full Text] [Related]
14. Comparison of Aphakic Refraction and Biometry-Based Formulae for Secondary In-The-Bag and Sulcus-Implanted Intraocular Lens Power Estimation in Children. Chang P, Li Z, Zhang F, Lin L, Kou J, Zhao YE. Ophthalmic Res; 2021 May; 64(6):1048-1054. PubMed ID: 33142284 [Abstract] [Full Text] [Related]
16. Accuracy of intraocular lens power calculations in eyes with axial length <22.00 mm. Day AC, Foster PJ, Stevens JD. Clin Exp Ophthalmol; 2012 Dec; 40(9):855-62. PubMed ID: 22594574 [Abstract] [Full Text] [Related]
17. Comparison of Hoffer Q and Haigis formulae for intraocular lens power calculation according to the anterior chamber depth in short eyes. Eom Y, Kang SY, Song JS, Kim YY, Kim HM. Am J Ophthalmol; 2014 Apr; 157(4):818-824.e2. PubMed ID: 24345318 [Abstract] [Full Text] [Related]
18. Intraoperative optical refractive biometry for intraocular lens power estimation without axial length and keratometry measurements. Ianchulev T, Salz J, Hoffer K, Albini T, Hsu H, Labree L. J Cataract Refract Surg; 2005 Aug; 31(8):1530-6. PubMed ID: 16129287 [Abstract] [Full Text] [Related]
19. [Evaluation of intraocular lens power after keratorefractive surgery by IOLMaster]. Zhang FJ, Qi YY, Kong DY, Zhu SQ, Wang KJ, Yu FL. Zhonghua Yan Ke Za Zhi; 2010 Nov; 46(11):989-93. PubMed ID: 21211294 [Abstract] [Full Text] [Related]