These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Clinical comparison of branched DNA and reverse transcriptase-PCR and nucleic acid sequence-based amplification assay for the quantitation of circulating recombinant form_BC HIV-1 RNA in plasma. Pan P, Tao X, Zhang Q, Xing W, Sun X, Pei L, Jiang Y. AIDS; 2007 Dec; 21 Suppl 8():S27-32. PubMed ID: 18172387 [Abstract] [Full Text] [Related]
3. Multicenter comparison of Roche COBAS AMPLICOR MONITOR version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma. Murphy DG, Côté L, Fauvel M, René P, Vincelette J. J Clin Microbiol; 2000 Nov; 38(11):4034-41. PubMed ID: 11060065 [Abstract] [Full Text] [Related]
10. Quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in cell-free cervicovaginal secretions: comparison of reverse transcription-PCR amplification (AMPLICOR HIV-A MONITOR 1.5) with enhanced-sensitivity branched-DNA assay (Quantiplex 3.0). Si-Mohamed A, Andreoletti L, Colombet I, Carreno MP, Lopez G, Chatelier G, Kazatchkine MD, Belec L. J Clin Microbiol; 2001 Jun; 39(6):2055-9. PubMed ID: 11376034 [Abstract] [Full Text] [Related]
11. Initial evaluation of the Roche COBAS TaqMan HIV-1 v2.0 assay for determining viral load in HIV-infected individuals. Taylor N, Schmid I, Egle A, Greil R, Patsch W, Oberkofler H. Antivir Ther; 2009 Jun; 14(8):1189-93. PubMed ID: 20032549 [Abstract] [Full Text] [Related]
12. Impact of HIV-1 genetic diversity on plasma HIV-1 RNA Quantification: usefulness of the Agence Nationale de Recherches sur le SIDA second-generation long terminal repeat-based real-time reverse transcriptase polymerase chain reaction test. Rouet F, Chaix ML, Nerrienet E, Ngo-Giang-Huong N, Plantier JC, Burgard M, Peeters M, Damond F, Ekouevi DK, Msellati P, Ferradini L, Rukobo S, Maréchal V, Schvachsa N, Wakrim L, Rafalimanana C, Rakotoambinina B, Viard JP, Seigneurin JM, Rouzioux C. J Acquir Immune Defic Syndr; 2007 Aug 01; 45(4):380-8. PubMed ID: 17468666 [Abstract] [Full Text] [Related]
13. Evaluation of the clinical sensitivity for the quantification of human immunodeficiency virus type 1 RNA in plasma: Comparison of the new COBAS TaqMan HIV-1 with three current HIV-RNA assays--LCx HIV RNA quantitative, VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 Monitor v1.5. Katsoulidou A, Petrodaskalaki M, Sypsa V, Papachristou E, Anastassopoulou CG, Gargalianos P, Karafoulidou A, Lazanas M, Kordossis T, Andoniadou A, Hatzakis A. J Virol Methods; 2006 Feb 01; 131(2):168-74. PubMed ID: 16194575 [Abstract] [Full Text] [Related]
14. Comparative performance of three viral load assays on human immunodeficiency virus type 1 (HIV-1) isolates representing group M (subtypes A to G) and group O: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR version 1.5, and Quantiplex HIV-1 RNA version 3.0. Swanson P, Soriano V, Devare SG, Hackett J. J Clin Microbiol; 2001 Mar 01; 39(3):862-70. PubMed ID: 11230396 [Abstract] [Full Text] [Related]
15. Molecular-based methods for quantifying HIV viral load. Peter JB, Sevall JS. AIDS Patient Care STDS; 2004 Feb 01; 18(2):75-9. PubMed ID: 15006182 [Abstract] [Full Text] [Related]
16. Comparative evaluation of the VERSANT HIV-1 RNA 1.0 kinetic PCR molecular system (kPCR) for the quantification of HIV-1 plasma viral load. Ruelle J, Jnaoui K, Lefèvre I, Lamarti N, Goubau P. J Clin Virol; 2009 Apr 01; 44(4):297-301. PubMed ID: 19230753 [Abstract] [Full Text] [Related]
17. [Comparison of NucliSens HIV-1 QT and Amplicor HIV-1 monitor 1.5 in detecting HIV-1 viral load]. Pan PL, Xu WY, Yao J, Tao XX, Pei LJ, Jiang Y. Zhonghua Shi Yan He Lin Chuang Bing Du Xue Za Zhi; 2007 Jun 01; 21(2):177-9. PubMed ID: 17653329 [Abstract] [Full Text] [Related]
18. Multicenter evaluation of the NucliSens EasyQ HIV-1 v1.1 assay for the quantitative detection of HIV-1 RNA in plasma. de Mendoza C, Koppelman M, Montès B, Ferre V, Soriano V, Cuypers H, Segondy M, Oosterlaken T. J Virol Methods; 2005 Jul 01; 127(1):54-9. PubMed ID: 15893566 [Abstract] [Full Text] [Related]
19. Evaluation of three different commercial procedures for quantifying human immunodeficiency virus type-1 RNA levels. Aschbacher R, Monari P, Lolli S, Donzelli C, Colangeli V, Vignoli M, Ramazzotti E, Furlini G, Re MC. New Microbiol; 1999 Jan 01; 22(1):1-9. PubMed ID: 10190111 [Abstract] [Full Text] [Related]
20. Measurement of HIV RNA in patients infected by subtype C by assays optimized for subtype B results in an underestimation of the viral load. Gottesman BS, Grosman Z, Lorber M, Levi I, Shitrit P, Mileguir F, Gottesman G, Chowers MY. J Med Virol; 2004 Jun 01; 73(2):167-71. PubMed ID: 15122788 [Abstract] [Full Text] [Related] Page: [Next] [New Search]