These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


287 related items for PubMed ID: 17410951

  • 1. A digital image analysis system for the assessment of tooth whiteness compared to visual shade matching.
    Lath DL, Wildgoose DG, Guan YH, Lilley TH, Smith RN, Brook AH.
    J Clin Dent; 2007; 18(1):17-20. PubMed ID: 17410951
    [Abstract] [Full Text] [Related]

  • 2. Shade matching assisted by digital photography and computer software.
    Schropp L.
    J Prosthodont; 2009 Apr; 18(3):235-41. PubMed ID: 19141046
    [Abstract] [Full Text] [Related]

  • 3. Visual whiteness ranking of a Vitapan 3D Master shade guide by untrained assessors.
    Lath DL, Wildgoose DG, Guan H, Lilley TH, Smith RN, Brook AH.
    J Clin Dent; 2006 Apr; 17(1):10-3. PubMed ID: 16838875
    [Abstract] [Full Text] [Related]

  • 4. The measurement of tooth whiteness by image analysis and spectrophotometry: a comparison.
    Guan YH, Lath DL, Lilley TH, Willmot DR, Marlow I, Brook AH.
    J Oral Rehabil; 2005 Jan; 32(1):7-15. PubMed ID: 15634295
    [Abstract] [Full Text] [Related]

  • 5. The use of objective digital matching to achieve an esthetic composite restoration.
    Jarad FD, Albadri SS, Mair LH.
    J Clin Dent; 2008 Jan; 19(1):9-13. PubMed ID: 18500153
    [Abstract] [Full Text] [Related]

  • 6. Evaluation of a newly developed visual shade-matching apparatus.
    Paravina RD.
    Int J Prosthodont; 2002 Jan; 15(6):528-34. PubMed ID: 12475156
    [Abstract] [Full Text] [Related]

  • 7. Application of digital imaging in tooth whitening randomized controlled trials.
    Sagel PA, Gerlach RW.
    Am J Dent; 2007 Sep; 20 Spec No A():7A-14A. PubMed ID: 19681252
    [Abstract] [Full Text] [Related]

  • 8. Reproducibility of tooth color gradation using a computer color-matching technique applied to ceramic restorations.
    Ishikawa-Nagai S, Ishibashi K, Tsuruta O, Weber HP.
    J Prosthet Dent; 2005 Feb; 93(2):129-37. PubMed ID: 15674222
    [Abstract] [Full Text] [Related]

  • 9. In vivo spectroradiometric evaluation of colour matching errors among five shade guides.
    Li Q, Yu H, Wang YN.
    J Oral Rehabil; 2009 Jan; 36(1):65-70. PubMed ID: 18976272
    [Abstract] [Full Text] [Related]

  • 10. The use of digital imaging for colour matching and communication in restorative dentistry.
    Jarad FD, Russell MD, Moss BW.
    Br Dent J; 2005 Jul 09; 199(1):43-9; discussion 33. PubMed ID: 16003426
    [Abstract] [Full Text] [Related]

  • 11. New shade guide for evaluation of tooth whitening--colorimetric study.
    Paravina RD, Johnston WM, Powers JM.
    J Esthet Restor Dent; 2007 Jul 09; 19(5):276-83; discussion 283. PubMed ID: 17877628
    [Abstract] [Full Text] [Related]

  • 12. Optimization of tooth color and shade guide design.
    Paravina RD, Majkic G, Imai FH, Powers JM.
    J Prosthodont; 2007 Jul 09; 16(4):269-76. PubMed ID: 17451478
    [Abstract] [Full Text] [Related]

  • 13. Shading of ceramic crowns using digital tooth shade matching devices.
    Baltzer A, Kaufmann-Jinoian V.
    Int J Comput Dent; 2005 Apr 09; 8(2):129-52. PubMed ID: 16201397
    [Abstract] [Full Text] [Related]

  • 14. A comparison between a new visual method of colour matching by intraoral camera and conventional visual and spectrometric methods.
    Lasserre JF, Pop-Ciutrila IS, Colosi HA.
    J Dent; 2011 Dec 09; 39 Suppl 3():e29-36. PubMed ID: 22101123
    [Abstract] [Full Text] [Related]

  • 15. Repeatability and interdevice reliability of two portable color selection devices in matching and measuring tooth color.
    Lagouvardos PE, Fougia AG, Diamantopoulou SA, Polyzois GL.
    J Prosthet Dent; 2009 Jan 09; 101(1):40-5. PubMed ID: 19105990
    [Abstract] [Full Text] [Related]

  • 16. Clinical performance of a newly developed spectrophotometric system on tooth color reproduction.
    Da Silva JD, Park SE, Weber HP, Ishikawa-Nagai S.
    J Prosthet Dent; 2008 May 09; 99(5):361-8. PubMed ID: 18456047
    [Abstract] [Full Text] [Related]

  • 17. Dental shade matching using a digital camera.
    Tam WK, Lee HJ.
    J Dent; 2012 Dec 09; 40 Suppl 2():e3-10. PubMed ID: 22713739
    [Abstract] [Full Text] [Related]

  • 18. Human-eye versus computerized color matching.
    Yap AU, Sim CP, Loh WL, Teo JH.
    Oper Dent; 1999 Dec 09; 24(6):358-63. PubMed ID: 10823085
    [Abstract] [Full Text] [Related]

  • 19. Accuracy of Three Shade-matching Devices in Replicating the Shade of Metal Ceramic Restorations: An in vitro Study.
    Lakhanpal S, Neelima MS.
    J Contemp Dent Pract; 2016 Dec 01; 17(12):1003-1008. PubMed ID: 27965487
    [Abstract] [Full Text] [Related]

  • 20. Measurement of stain on extracted teeth using spectrophotometry and digital image analysis.
    Lath DL, Smith RN, Guan YH, Karmo M, Brook AH.
    Int J Dent Hyg; 2007 Aug 01; 5(3):174-9. PubMed ID: 17615027
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 15.