These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
235 related items for PubMed ID: 17433694
21. Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire. Chang CW, Chen YN, Li CT, Chung YH, Chang CH, Peng YT. J Orthop Surg (Hong Kong); 2018; 26(3):2309499018789705. PubMed ID: 30037293 [Abstract] [Full Text] [Related]
22. Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study. Kandemir U, Matityahu A, Desai R, Puttlitz C. J Orthop Trauma; 2008 Oct; 22(9):605-10. PubMed ID: 18827589 [Abstract] [Full Text] [Related]
23. Performance of modified anatomic plates is comparable to proximal femoral nail, dynamic hip screw and anatomic plates: finite element and biomechanical testing. Oken OF, Soydan Z, Yildirim AO, Gulcek M, Ozlu K, Ucaner A. Injury; 2011 Oct; 42(10):1077-83. PubMed ID: 21474133 [Abstract] [Full Text] [Related]
24. Fixation of multifragmentary patella fractures using a bilateral fixed-angle plate. Thelen S, Betsch M, Schneppendahl J, Grassmann J, Hakimi M, Eichler C, Windolf J, Wild M. Orthopedics; 2013 Nov; 36(11):e1437-43. PubMed ID: 24200450 [Abstract] [Full Text] [Related]
25. Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model. Dougherty PJ, Kim DG, Meisterling S, Wybo C, Yeni Y. J Orthop Trauma; 2008 Jul; 22(6):399-403. PubMed ID: 18594304 [Abstract] [Full Text] [Related]
26. Treatment of inferior patellar pole avulsion fractures with pole resection and patellotibial cerclage wire. Singh RP, Shah RK, Srivastava MP. Nepal Med Coll J; 2007 Jun; 9(2):93-5. PubMed ID: 17899956 [Abstract] [Full Text] [Related]
27. [A finite element analysis of petal-shaped poly-axial locking plate fixation in treatment of Y-shaped patellar fracture]. Meng D, Ouyang Y, Hou C. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2017 Dec 15; 31(12):1456-1461. PubMed ID: 29806387 [Abstract] [Full Text] [Related]
28. Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability. Stoffel K, Lorenz KU, Kuster MS. J Orthop Trauma; 2007 Jul 15; 21(6):362-8. PubMed ID: 17620993 [Abstract] [Full Text] [Related]
29. The effect of an augmentation patella prosthesis versus patelloplasty on revision patellar kinematics and quadriceps tendon force: an ex vivo study. Mountney J, Wilson DR, Paice M, Masri BA, Greidanus NV. J Arthroplasty; 2008 Dec 15; 23(8):1219-31. PubMed ID: 18534488 [Abstract] [Full Text] [Related]
30. Comparison of metacarpal plating methods. Sohn RC, Jahng KH, Curtiss SB, Szabo RM. J Hand Surg Am; 2008 Mar 15; 33(3):316-21. PubMed ID: 18343284 [Abstract] [Full Text] [Related]
31. Design and Validation of a Smile-Necklace Plate for Treating Inferior Patellar Pole Avulsion Fractures: A Review and Hypothesis. Zhu W, Xu L, Xie K, Li X, Zhang X, Fang S, Yang J. Orthop Surg; 2022 Nov 15; 14(11):2799-2808. PubMed ID: 36125193 [Abstract] [Full Text] [Related]
32. Medial marginal fracture of the patella following patellar dislocation. Toritsuka Y, Horibe S, Hiro-Oka A, Mitsuoka T, Nakamura N. Knee; 2007 Dec 15; 14(6):429-33. PubMed ID: 17884512 [Abstract] [Full Text] [Related]
33. Biomechanical analysis of bicondylar tibial plateau fixation: how does lateral locking plate fixation compare to dual plate fixation? Higgins TF, Klatt J, Bachus KN. J Orthop Trauma; 2007 May 15; 21(5):301-6. PubMed ID: 17485994 [Abstract] [Full Text] [Related]
34. Assessment of carbon fibre composite fracture fixation plate using finite element analysis. Saidpour SH. Ann Biomed Eng; 2006 Jul 15; 34(7):1157-63. PubMed ID: 16732432 [Abstract] [Full Text] [Related]
35. [A "blocking" loop in the surgical treatment of avulsive fractures of the patella and damage to its ligament]. Girshin SG, Shmidt IZ, Dubrov VE, Skorogudaev AV. Ortop Travmatol Protez; 1991 Jan 15; (1):39-41. PubMed ID: 2067811 [Abstract] [Full Text] [Related]
36. Biomechanical optimization of bone plates used in rigid fixation of mandibular fractures. Lovald ST, Wagner JD, Baack B. J Oral Maxillofac Surg; 2009 May 15; 67(5):973-85. PubMed ID: 19375006 [Abstract] [Full Text] [Related]
37. Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanic study. McCall TA, Conrad B, Badman B, Wright T. J Hand Surg Am; 2007 May 15; 32(6):806-12. PubMed ID: 17606058 [Abstract] [Full Text] [Related]
38. Assessment of function-graded materials as fracture fixation bone-plates under combined loading conditions using finite element modelling. Fouad H. Med Eng Phys; 2011 May 15; 33(4):456-63. PubMed ID: 21146439 [Abstract] [Full Text] [Related]
40. Biomechanical comparison of the holding strength of a peek-optima circular plate versus a stainless steel oblique T-plate for radioscapholunate arthrodesis. Isaacs JE, Yen Shipley N, Owen JR, Owings FP, Wayne JS. J Hand Surg Am; 2008 Dec 15; 33(10):1765-9. PubMed ID: 19084175 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]